← Back
Two stories - detached, small or mid-size
109-45 197 STREET
QUEENS · Hollis · BIN 4234026
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R2Zoning
2,218 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,000 sf lot · 0.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Roof6p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/07/2023$875K—— → —$394/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC104/05/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SOLOGISTICS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNATION SOLAR SYSTEMSGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802104/05/2024
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
06/11/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF STRUCTURE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
Q01026411-I1
04/09/2024
Permit issued — Solar
Q01026411-I1-SL
04/05/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF STRUCTURE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
Q01026411-I1
03/27/2024
Special inspection requirement — Final
Chun Feng
03/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
03/27/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chun Feng
03/27/2024
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
03/27/2024
Special inspection requirement — Air barrier - visual inspection
Chun Feng
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNATION SOLAR SYSTEMS04/09/2024
BIS—ISSUEDN/A01/29/2001
1 project · most recent 05/22/2024
General Wiring
FiledStatusContractorScope
05/22/2024CompleteGALLANT ELEC'L CONST, INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/27/2024FinalChun Fengprogress
03/27/2024Fire-Resistant Penetrations and JointsChun Fengspecial
03/27/2024Structural Stability – Alterations of existing buildingsChun Fengspecial
03/27/2024Energy Code Compliance InspectionsChun Fengprogress
03/27/2024Air barrier - visual inspectionChun Fengenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/23/2026Q01026411-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/30/2026Q01026411-I1Open ↗
09/30/2026Q01026411-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/23/2026Q01026411-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/30/2026Q01026411-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/23/2026Q01026411-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01026411-I1Open ↗