← Back
BuildNYC
Two family brick
109 AMERSFORT PLACE
BROOKLYN · BIN 3205818
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R5BZoning
2,120 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family brick · Owner of record: Equity 555 · 2,338 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1p · 1 filing · 20 docs
Floor 41p · 1 filing · 20 docs
Floor 31p · 1 filing · 20 docs
Floor 25p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar6p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Equity 555103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/05/2025$669K—RETAINED REALTY, INC. → Equity 555$316/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Sion Consulting Engineering503/12/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Sion Consulting Engineering1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J Designsspecialty_contractor303/21/2026
Power Surge ElectricElectrical103/22/2026
Renew PlumbingPlumbing107/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Sion Consulting Engineering1108403/12/2026
Building Lifecycle
07/09/2026
Signed off — Alteration
THIS APPLICATION IS FILED FOR INTERIOR &EXTERIOR RENOVATION, PARTIAL DEMOLITION, STRUCTURAL AND MULTIPLE SISTERING WOOD JOISTS REPAIR, WHERE NEEDED IN ORDER TO ADDRESS ECB VIOLATIONS:39154332L; 39153729P; 39153728N; 39153727L;39151625L;39109891P;35154735K
B01255594-I1
07/01/2026
Signed off — Alteration
THIS APPLICATION IS FILED FOR INTERIOR &EXTERIOR RENOVATION, PARTIAL DEMOLITION, STRUCTURAL AND MULTIPLE SISTERING WOOD JOISTS REPAIR, WHERE NEEDED IN ORDER TO ADDRESS ECB VIOLATIONS:39154332L; 39153729P; 39153728N; 39153727L;39151625L;39109891P;35154735K
B01255594-S2
06/25/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/23/2026
Closed: Construction: other (DOB violation)
DOB violation · closed on the city's record
05/29/2026
Closed: Seal all accessible openings at exposure 2 and 3
DOB violation · closed on the city's record
75 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offRenew Plumbing12/16/2025
DOB NOWMechanical SystemsSigned-offJ&J Designs09/16/2025
1 project · most recent 03/12/2026
Ventilation Systems
FiledStatusContractorScope
03/12/2026Signed-offJ&J DesignsVentilation Systems
1 project · most recent 03/12/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/12/2026Signed-offRenew PlumbingGas, Water/Sanitary
2 projects · most recent 10/21/2026
General Wiring
FiledStatusContractorScope
10/21/2026Permit IssuedPower Surge ElectricGeneral Wiring
12/07/2025CompletePower Surge ElectricGeneral Wiring
1 project · most recent 03/12/2026
Wood
FiledStatusContractorScope
03/12/2026Signed-offRenew PlumbingWood
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/25/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/30/2026Pass-Final General Construction Non-Directive 14PassView ↗
12/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 73
DateRequirementInspectorRole
04/21/2026Heating Systemssion hourizadehspecial
04/21/2026Fire-Resistant Penetrations and Jointssion hourizadehspecial
04/21/2026Structural Stability – Alterations of existing buildingssion hourizadehspecial
04/21/2026Masonrysion hourizadehspecial
04/21/2026Mechanical Systemssion hourizadehspecial
04/21/2026Fire-Resistance Rated Constructionsion hourizadehprogress
04/21/2026Energy Code Compliance Inspectionssion hourizadehprogress
04/21/2026Finalsion hourizadehprogress
04/21/2026Interior lighting powersion hourizadehenergy_progress
04/21/2026Fenestration areassion hourizadehenergy_progress
04/21/2026Fenestration air leakagesion hourizadehenergy_progress
04/21/2026HVAC-R and service water heating system controlssion hourizadehenergy_progress
04/21/2026Insulation placement and R valuession hourizadehenergy_progress
04/21/2026HVAC-R and service water heating equipmentsion hourizadehenergy_progress
04/21/2026Permanent certificatesion hourizadehenergy_progress
04/21/2026Fenestration and door U-factor and product ratingssion hourizadehenergy_progress
04/21/2026HVAC-R and service water piping design and insulationsion hourizadehenergy_progress
04/21/2026Maintenance informationsion hourizadehenergy_progress
03/12/2026Fenestration air leakagesion hourizadehenergy_progress
03/12/2026Fire-Resistant Penetrations and Jointssion hourizadehspecial
03/12/2026Heating Systemssion hourizadehspecial
03/12/2026Masonrysion hourizadehspecial
03/12/2026Mechanical Systemssion hourizadehspecial
03/12/2026Structural Stability – Alterations of existing buildingssion hourizadehspecial
03/12/2026Energy Code Compliance Inspectionssion hourizadehprogress
Latest 25 of 73.
27 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account