← Back
Predominantly retail with other uses
109 WEST 24 STREET
MANHATTAN · BIN 1014982
💬 Discuss this project
1902Year Built
7Stories
K4Building Class
M1-8A/R11Zoning
42,670 sfGross Floor Area
14Units
LL97 Covered42 Open Violations 24 unresolved · 18 paperwork only ▸FISP: No Report Filed
Predominantly retail with other uses · Owner of record: OAC ADELPHI, LLC · 5,712 sf lot · 7.47 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction19p · 5 filings · 20 docs
Floor 7Under Construction17p · 3 filings · 20 docs
Floor 6Under Construction22p · 3 filings · 20 docs
Floor 5Under Construction17p · 3 filings · 20 docs
Floor 4Under Construction20p · 3 filings · 20 docs
Floor 3Under Construction23p · 4 filings · 20 docs
Floor 2Under Construction22p · 3 filings · 20 docs
Floor 1Under Construction17p · 3 filings · 20 docs
CellarUnder Construction18p · 3 filings · 20 docs
2 jobs · most recent 12/27/2024
Heating and Air Conditioning Systems Ventilation Systems Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
12/27/2024——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-EP72TNU-A 72,000 BTU · Vrf Outdoor ×2
PUHY-EP168TNU-A 168,000 BTU · Vrf Outdoor ×1
Ventilation
Mitsubishi Electric SQ-98-VG 350 CFM ×3
Greenheck SP-B150 125 CFM · Exhaust Fan ×1
SQ-98-VG 280 CFM · Exhaust Fan ×1
11/21/2022Permit IssuedKEDC CORPAssociated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric puhy-ep168tnu-a 188,000 BTU · Vrf Outdoor ×3
PKA-A24NKA7 28,000 BTU · Heat Pump Outdoor ×2
puhy-ep192tnu-a 215,000 BTU · Vrf Outdoor ×1
puhy-ep72tnu-a 80,000 BTU · Vrf Outdoor ×1
puhy-ep96tnu-a 108,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck G-098-VG 1,100 CFM · Exhaust Fan ×2
SQ-98-VG 440 CFM · Exhaust Fan ×2
G-100-VG 1,100 CFM · Exhaust Fan ×1
SQ-60 50 CFM · Exhaust Fan
2 jobs · most recent 08/25/2026
Water/Sanitary
FiledStatusContractorScope
08/25/2026Permit IssuedHI-TECH PLUMBING & HEATING LLCWater/Sanitary
12/27/2024——Water/Sanitary
6 jobs · most recent 07/02/2024
General Wiring
FiledStatusContractorScope
07/02/2024Permit IssuedPOWER SURGE ELECTRIC, INC—
06/26/2024Permit IssuedPOWER SURGE ELECTRIC, INC—
01/17/2023Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
01/16/2023Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
12/14/2021Permit IssuedMER ELECTRIC, INCGeneral Wiring
12/14/2021Permit IssuedMER ELECTRIC, INC—
Building Lifecycle
All (164)Filed (9)Permit Issued (6)Facade (FISP) (8)Violation (60)Inspection (6)Objection (52)Special Inspection (23)
09/08/2026
Objection resolved — Addressed
09/04/2026
Objection raised — Scope
08/25/2026
Filed — Alteration
plumbing work associated with 102796306.
M00758699-P1
08/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Max Lee
08/24/2026
Special inspection requirement — Maintenance information
Max Lee
08/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
Max Lee
08/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
Max Lee
08/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Max Lee
08/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Max Lee
08/24/2026
Special inspection requirement — Tenant Protection Plan Compliance
08/17/2026
Permit issued — Plumbing
M00758699-I1-PL
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Resolved
07/17/2026
Objection resolved — Resolved
07/14/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/14/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/07/2025
Violation issued (ECB, open)
Construction
11/07/2025
Violation issued (ECB, open)
Construction
11/07/2025
Violation issued (ECB, open)
Construction
08/15/2025
Objection raised — Scope
08/14/2025
Objection raised — Scope
08/14/2025
Objection raised — Scope
08/14/2025
Objection raised — Cost
08/14/2025
Objection raised — Scope
08/14/2025
Objection raised — Fire_Protection
07/28/2025
Objection resolved — Resolved
07/28/2025
Objection resolved — Resolved
07/28/2025
Objection resolved — Resolved
07/28/2025
Objection resolved — Resolved
06/27/2025
Permit issued — Mechanical Systems
M00758698-I1-MS
02/24/2025
Objection raised — Structural
02/24/2025
Objection raised — Scope
02/24/2025
Objection raised — Scope
02/24/2025
Objection raised — Scope
02/24/2025
Objection raised — Scope
01/11/2025
Objection resolved — Addressed
01/11/2025
Objection resolved — Addressed
01/10/2025
Objection raised — Scope
01/06/2025
Objection resolved — Addressed
01/06/2025
Objection resolved — Addressed
01/06/2025
Objection resolved — Addressed
01/03/2025
Objection raised — Plumbing
01/03/2025
Objection raised — Plumbing
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Energy
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Inspections
01/03/2025
Objection raised — Structural
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Fire_Protection
12/27/2024
Filed — Alteration
PERFORM MECHANICAL WORK FOR THE COMMERCIAL SPACE OF AN EXISTING 7 STORY MIXED USED BUILDING. DESIGN INCLUDES THE INSTALLATION OF COOLING/HEATING SYSTEM, VENTILATION SYSTEM AND MECHANICAL EXHAUST. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
M01140485-S1
12/27/2024
Filed — Alteration
PERFORM MECHANICAL WORK FOR THE COMMERCIAL SPACE OF AN EXISTING 7 STORY MIXED USED BUILDING. DESIGN INCLUDES THE INSTALLATION OF COOLING/HEATING SYSTEM, VENTILATION SYSTEM AND MECHANICAL EXHAUST. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
M01140485-S3
12/27/2024
Filed — Alteration
PERFORM MECHANICAL WORK FOR THE COMMERCIAL SPACE OF AN EXISTING 7 STORY MIXED USED BUILDING. DESIGN INCLUDES THE INSTALLATION OF COOLING/HEATING SYSTEM, VENTILATION SYSTEM AND MECHANICAL EXHAUST. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
M01140485-S2
12/24/2024
Objection raised — Scope
Latest 60 of 164 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OKADA ACQUISITION COMPANY1608/28/2026
OAC ADELPHI, LLC1903/22/2026
KEDC KEDC CORP103/22/2026
KEDC203/22/2026
111 W 24 ST ASSOCIATES403/22/2026
111 WEST 24 ST ASSOC1003/22/2026
11 WEST 24 ST ASSOCS C/O103/22/2026
111 WEST 24TH ST ASSOCS403/22/2026
111 WEST 24ST ASSOCS C/O103/22/2026
111 WEST 24 ASSOCIATES103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/28/2021$16.2M—— → —$381/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALL CITY ENGINEERING, P.C.708/25/2026
PEACHY CONSTRUCTION112/02/2024
PROJECT TACTICAL SOLUTIONS, LLC104/08/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
QUICK FILING OF NY INC703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KEDC CORPGeneral Contractor507/08/2026
HI-TECH PLUMBING & HEATINGPlumbing308/18/2026
H&F IRON WORKSElectrical103/21/2026
CAL CLASSIElectrical103/21/2026
STEPHENS, KElectrical103/21/2026
SILVERIO, ISMAELElectrical103/21/2026
FOY, REMERElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PROJECT TACTICAL SOLUTION5859408/25/2026
SAHEB ARCHITECTURE PLLC7018112/02/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedHI-TECH PLUMBING & HEATING08/17/2026
DOB NOWMechanical SystemsPermit IssuedKEDC06/27/2025
DOB NOWMechanical SystemsPermit IssuedKEDC07/15/2024
DOB NOWPlumbingPermit IssuedHI-TECH PLUMBING & HEATIN12/05/2023
DOB NOWMechanical SystemsPermit IssuedKEDC02/14/2023
DOB NOWPlumbingPermit IssuedHI-TECH PLUMBING & HEATIN02/03/2023
BIS—ISSUEDKEDC CORP07/31/2025
BIS—ISSUEDKEDC CORP06/27/2025
BIS—ISSUEDKEDC CORP07/16/2024
BIS—ISSUEDKEDC CORP09/14/2022
BIS—ISSUEDKEDC CORP12/20/2021
BIS—ISSUEDNEW MONTAUK CORP12/31/2019
BIS—ISSUEDNEW MONTAUK CORP01/02/2019
BIS—ISSUEDNEW MONTAUK CORP01/26/2018
BIS—ISSUEDNEW MONTAUK CORP01/04/2017
BIS—ISSUEDNEW MONTAUK CORP01/15/2016
BIS—ISSUEDMONTAUK RUG & CARPET.CORP06/25/2015
BISEQISSUEDSHAH GROUP ENTERPRISES IN03/30/2015
BIS—ISSUEDMONTAUK RUG & CARPET.CORP07/09/2014
BIS—ISSUEDMONTAUK RUG & CARPET.CORP08/10/2010
BISEQISSUEDROCK SCAFFOLDING CORP04/22/2010
BISOTISSUEDMONTAUK RUG & CARPET.CORP04/02/2010
BISSPISSUEDQMB PLUMBING & HTG INC03/26/2009
BIS—ISSUEDMONTAUK RUG & CARPET CORP.09/14/2005
BIS—ISSUEDTICO GENERAL CONSTRUCTION CORP.09/17/2004
BIS—ISSUEDTICO GENERAL CONSTRUCTION CORP.01/20/2004
BISEQISSUEDCLARK & WILKINS INDUSTRIES03/27/2003
BISEQISSUEDCLARK & WILKINS INDUSTRIES03/27/2003
BIS—ISSUEDMONTAUK RUG & CARPET CORP01/17/2003
BIS—ISSUEDMONTAUK RUG & CARPET CORP08/28/2002
BISMHISSUEDDAVRIAL ENTERPRISES INC03/29/2001
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/14/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/14/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/14/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/26/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
08/24/2026Fire-Resistant Penetrations and JointsMax Leespecial
08/24/2026Maintenance informationMax Leeenergy_progress
08/24/2026HVAC-R and service water heating equipmentMax Leeenergy_progress
08/24/2026HVAC-R and service water heating system controlsMax Leeenergy_progress
08/24/2026HVAC-R and service water piping design and insulationMax Leeenergy_progress
08/24/2026Energy Code Compliance InspectionsMax Leeprogress
08/24/2026Tenant Protection Plan Compliance—special
12/24/2024Post-installed Anchors—special
12/20/2024Tenant Protection Plan Compliance—special
12/10/2024Sprinkler Systems—special
11/11/2024Fire-Resistant Penetrations and JointsRitu Sahebspecial
11/11/2024Tenant Protection Plan ComplianceRitu Sahebspecial
11/11/2024FinalRitu Sahebprogress
11/11/2024Interior lighting powerRitu Sahebenergy_progress
11/21/2022HVAC-R and service water piping design and insulationMax Leeenergy_progress
11/21/2022Maintenance informationMax Leeenergy_progress
11/21/2022HVAC-R and service water heating equipmentMax Leeenergy_progress
11/21/2022HVAC-R and service water heating system controlsMax Leeenergy_progress
11/21/2022Energy Code Compliance InspectionsMax Leeprogress
11/16/2022Tenant Protection Plan ComplianceMax Leespecial
06/17/2022Fire-Resistant Penetrations and JointsMax Leespecial
04/07/2022MasonryMax Leespecial
02/28/2022FinalMax Leeprogress
▾Documents — 178 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/02/2026M00689260-I1Request digital key ↗
09/01/2026M00760574-I1Request digital key ↗
09/01/2026M00758699-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits41
▸BISPLAN / WORK APPROVAL APPLICATION31
10/30/2025102796306Open ↗
10/29/2025102796306Open ↗
09/29/2025102796306Open ↗
Showing 3 of 31 on file for this type
▸BISWORK PERMIT APPLICATION10
07/16/2024102796306Open ↗
06/26/2024102796306Open ↗
06/18/2024102796306Open ↗
Showing 3 of 10 on file for this type
▸Seals & Professional Certifications36
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026M00760574-I1Open ↗
09/01/2026M00758699-P1Open ↗
08/25/2026M01140485-S1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
10/03/2011120784669Open ↗
09/09/2010120209531Open ↗
04/09/2010120314338Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/23/2026M00758699-P1Open ↗
09/23/2026M00758699-P1Open ↗
09/05/2026M00689260-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026M00758699-P1Open ↗
09/19/2026M01140485-I1Open ↗
09/19/2026M01140485-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
10/03/2011120784669Open ↗
04/08/2010120314267Open ↗
12/04/2009120209531Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
10/03/2011120784669Open ↗
04/08/2010120314267Open ↗
12/04/2009120209531Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/26/2015140322782Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/26/2015140322782Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/26/2015140322782Open ↗
▸Trade Schedules & Equipment13
▸BISSCHEDULE B - PLUMBING11
09/29/2025102796306Open ↗
09/10/2025102796306Open ↗
06/17/2025102796306Open ↗
Showing 3 of 11 on file for this type
▸BISSELF-CERT PLUMBING NOTICE1
03/24/2010110376389Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
03/24/2010110376389Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
08/26/2024102796306Open ↗
▸Environmental & Asbestos21
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'9
10/03/2011120784669Open ↗
10/03/2011120784669Open ↗
10/03/2011120784669Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/01/2026M00760574-I1Open ↗
09/01/2026M00758699-P1Open ↗
08/25/2026M01140485-S3Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
04/08/2010120314267Open ↗
12/04/2009120209531Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)2
10/03/2011120784669Open ↗
10/03/2011120784669Open ↗
▸Approvals, Objections & Sign-offs28
▸BISSCHEDULE A - OCCUPANCY / USE17
10/30/2025102796306Open ↗
10/29/2025102796306Open ↗
06/30/2025102796306Open ↗
Showing 3 of 17 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
10/03/2011120784669Open ↗
10/03/2011120784669Open ↗
04/09/2010120314338Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/29/2025102796306Open ↗
04/19/2010110376389Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
09/09/2010120209531Open ↗
04/19/2010110376389Open ↗
▸BISSUPERSEDING LETTER1
12/20/2021102796306Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
10/03/2011120784669Open ↗
09/09/2010120209531Open ↗
04/19/2010110376389Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms13
▸BISADDITIONAL INFORMATION6
08/29/2025102796306Open ↗
06/17/2025102796306Open ↗
04/22/2025102796306Open ↗
Showing 3 of 6 on file for this type
▸BISBOROUGH INTAKE FORM3
07/16/2024102796306Open ↗
07/16/2024102796306Open ↗
12/20/2021102796306Open ↗
▸BISEFILING COVER SHEET3
10/03/2011120784669Open ↗
04/08/2010120314267Open ↗
11/18/2008110376389Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/26/2015140322782Open ↗
▸Other Documents11
▸DOB NOWLoft Board Certificate8
09/01/2026M00758699-P1Open ↗
08/13/2026M00760574-I1Open ↗
08/13/2026M01140485-S3Open ↗
Showing 3 of 8 on file for this type
▸BISLOFT BOARD CERTIFICATE2
03/26/2015140322782Open ↗
11/18/2008110376389Open ↗
▸BISSupporting Document: Fee Exempt1
02/12/2010120209531Open ↗