← Back
BuildNYC
Two stories - detached, small or mid-size
11-42 WELLING COURT
QUEENS · BIN 4005529
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R4-1Zoning
1,064 sfGross Floor Area
1Units
2 Active Violations 0 unresolved · 2 paperwork only ▸
Two stories - detached, small or mid-size · Owner of record: United Assets Corporation USA · 1,600 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofInterior renovation of dwelling3p · 2 filings · 19 docs
Floor 21p · 1 filing · 9 docs
Floor 1Interior renovation of dwelling2p · 2 filings · 19 docs
CellarInterior renovation of dwelling3p · 2 filings · 19 docs
Site & exterior1p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/30/2019$456K—CWABS, INC ASSET-BACKED CERTIFICATE SERIES 2006-23 → UNITED ASSETS CORPORATION USA$429/sf building
11/08/2018$646K—Private party → THE BANK OF NEW YORK MELLON$607/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Carusone & Cherres Architects406/24/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AB Works Processing403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Rize ConstructionGeneral Contractor603/21/2026
Rize ConstructionScaffold603/21/2026
John Fitzgerald Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Carusone & Cherres6166103/29/2021
Building Lifecycle
06/03/2023
Permit expired, never signed off — Plumbing
The city's record still shows this permit as issued, with no sign-off on its filing
Q00581815-I1-PL
02/09/2023
Permit expired, never signed off — Construction Fence
The city's record still shows this permit as issued, with no sign-off on its filing
Q00450739-I1-FN
02/09/2023
Permit expired, never signed off — Earth Work
The city's record still shows this permit as issued, with no sign-off on its filing
Q00478199-I1-GC
07/13/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/12/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
57 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJohn Fitzgerald Plumbing & Heating06/22/2022
DOB NOWConstruction FencePermit IssuedRize Construction03/08/2022
DOB NOWEarth WorkPermit IssuedRize Construction03/07/2022
DOB NOWStructuralPermit IssuedRize Construction11/10/2021
DOB NOWConstruction FencePermit IssuedRize Construction10/26/2021
1 project · most recent 06/24/2022
Gas Water/Sanitary
FiledStatusContractorScope
06/24/2022Permit IssuedJohn Fitzgerald Plumbing & HeatingGas, Water/Sanitary
1 project · most recent 04/01/2022
General Wiring
FiledStatusContractorScope
04/01/2022Permit IssuedHazrat RamatalliGeneral Wiring
1 project · most recent 03/29/2021
Wood
FiledStatusContractorScope
03/29/2021Permit IssuedRize ConstructionWood
1 project · most recent 09/20/2021
Fence
FiledStatusContractorScope
09/20/2021Permit IssuedRize ConstructionFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/13/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/12/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/12/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
12/08/2021HVAC-R and service water piping design and insulationJORGE CHERRESenergy_progress
12/08/2021HVAC-R and service water heating system controlsJORGE CHERRESenergy_progress
12/08/2021HVAC-R and service water heating equipmentJORGE CHERRESenergy_progress
07/29/2021Subgrade InspectionsJORGE CHERRESspecial
07/29/2021Fire-Resistance Rated ConstructionJORGE CHERRESprogress
07/29/2021Structural Wood FrameJORGE CHERRESprogress
07/29/2021Fenestration air leakageJORGE CHERRESenergy_progress
07/29/2021Concrete - Cast-In-PlaceJORGE CHERRESspecial
07/29/2021Fire-Resistant Penetrations and JointsJORGE CHERRESspecial
07/29/2021Fenestration and door U-factor and product ratingsJORGE CHERRESenergy_progress
07/29/2021Insulation placement and R valuesJORGE CHERRESenergy_progress
07/29/2021Maintenance informationJORGE CHERRESenergy_progress
07/29/2021Permanent certificateJORGE CHERRESenergy_progress
07/29/2021Fenestration areasJORGE CHERRESenergy_progress
07/29/2021Air barrier - visual inspectionJORGE CHERRESenergy_progress
03/10/2021Structural Stability – Alterations of existing buildingsJORGE CHERRESspecial
03/10/2021Lighting in dwelling unitsJORGE CHERRESenergy_progress
03/10/2021Footing and FoundationJORGE CHERRESprogress
03/10/2021FinalJORGE CHERRESprogress
21 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account