← Back
BuildNYC
Two stories - detached, small or mid-size
11-67 VIRGINIA STREET
QUEENS · BIN 4297729
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3XZoning
4,891 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 9,041 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof2p · 1 filing · 20 docs
Attic25p · 2 filings · 20 docs
Floor 226p · 2 filings · 20 docs
Floor 1New curb cut installation28p · 4 filings · 20 docs
Cellar28p · 2 filings · 20 docs
Site & exteriorConstruction fence and gate29p · 3 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Shmuel D. Flaum, Architect1311/10/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
All-Boro Rehab ConstrctGeneral Contractor804/09/2026
All-Boro Rehab ConstrctScaffold407/08/2026
All-Boro Rehab Constructionspecialty_contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
David Katz, P.E.6087205/13/2025
Shmuel D. Flaum4278905/13/2025
Building Lifecycle
04/07/2026
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
03/06/2026
Signed off — Alteration
PROPOSED ENLARGEMENT AT SIDE AND REAR OF EXISTING SINGLE FAMILY DWELLING
Q00460044-I1
03/06/2026
Signed off — Alteration
PROPOSED ENLARGEMENT AT SIDE AND REAR OF EXISTING SINGLE FAMILY DWELLING
Q00460044-S1
03/05/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/31/2025
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
109 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offAll-Boro Rehab Constrct11/28/2025
DOB NOWPlumbingSigned-offAll-Boro Rehab Construction02/21/2025
DOB NOWCurb CutSigned-offAll-Boro Rehab Constrct02/19/2025
DOB NOWGeneral ConstructionSigned-offAll-Boro Rehab Constrct11/27/2024
DOB NOWFoundationSigned-offAll-Boro Rehab Constrct12/26/2023
DOB NOWConstruction FenceSigned-offAll-Boro Rehab Constrct12/26/2023
DOB NOWPlumbingSigned-offAll-Boro Rehab Construction11/02/2023
DOB NOWConstruction FenceSigned-offAll-Boro Rehab Constrct07/11/2023
DOB NOWGeneral ConstructionSigned-offAll-Boro Rehab Constrct03/30/2023
DOB NOWMechanical SystemsSigned-offAll-Boro Rehab Constrct03/24/2023
DOB NOWConstruction FenceSigned-offAll-Boro Rehab Constrct07/16/2022
BIS—ISSUEDAll-Boro Rehab Construction03/10/2025
1 project · most recent 06/17/2025
General Wiring
FiledStatusContractorScope
06/17/2025CompleteHirschel ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
04/07/2026Pass-Final Curb Cut Non-Directive 14PassView ↗
03/05/2026Pass-Final General Construction Non-Directive 14PassView ↗
12/31/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
05/06/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
03/27/2025Fail-Final General Construction Non-Directive 14FailView ↗
03/17/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
02/28/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/20/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/05/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/01/2024Fail-Final General Construction Non-Directive 14FailView ↗
07/23/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/22/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 74
DateRequirementInspectorRole
04/30/2025Subsurface Investigations (Borings/Test Pits)Shmuel Flaumspecial
04/30/2025Insulation placement and R valuesShmuel Flaumenergy_progress
04/30/2025Fenestration air leakageShmuel Flaumenergy_progress
04/30/2025Protection of exposed foundation insulationShmuel Flaumenergy_progress
04/30/2025Interior lighting powerShmuel Flaumenergy_progress
04/30/2025Fenestration and door U-factor and product ratingsShmuel Flaumenergy_progress
04/30/2025Air barrier — testing Shmuel Flaumenergy_progress
04/30/2025Fenestration areasShmuel Flaumenergy_progress
04/30/2025PreliminaryShmuel Flaumprogress
04/30/2025Fire-Resistance Rated ConstructionShmuel Flaumprogress
04/30/2025Energy Code Compliance InspectionsShmuel Flaumprogress
04/30/2025Concrete - Cast-In-PlaceShmuel Flaumspecial
04/30/2025Excavations - Sheeting, Shoring, and BracingDavid Katzspecial
04/30/2025Fire-Resistant Penetrations and JointsShmuel Flaumspecial
04/30/2025Air barrier - visual inspectionShmuel Flaumenergy_progress
04/30/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationShmuel Flaumspecial
04/30/2025Structural Stability – Alterations of existing buildingsShmuel Flaumspecial
04/30/2025Subgrade InspectionsDavid Katzspecial
01/21/2025Interior lighting powerShmuel Flaumenergy_progress
01/21/2025Electric vehicle service equipment requirementsShmuel Flaumenergy_progress
01/21/2025Insulation placement and R valuesShmuel Flaumenergy_progress
01/21/2025Protection of exposed foundation insulationShmuel Flaumenergy_progress
01/21/2025Footing and FoundationShmuel Flaumprogress
01/21/2025FinalDavid Katzprogress
01/21/2025Energy Code Compliance InspectionsShmuel Flaumprogress
Latest 25 of 74.
124 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account