Two stories - detached, small or mid-size
11 ALBOURNE AVENUE EAST
STATEN ISLAND · Annadale-Huguenot-Prince's Bay-Woodrow · BIN 5083430
💬 Discuss this project
1955Year Built
2Stories
A1Building Class
R3XZoning
2,132 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 8,000 sf lot · 0.27 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof2p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC107/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854107/08/2024
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (5)
08/28/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
S01058714-I1
07/25/2024
Permit issued — Solar
S01058714-I1-SL
07/08/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
S01058714-I1
05/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/30/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/30/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/30/2024
Special inspection requirement — Final
TOM PETERSEN
05/30/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
12/18/2006
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC07/25/2024
BISPLISSUEDCAPITAL CONTR P&H CORP02/15/2005
BISPLISSUEDJ.P.B. PL. CONSTRUCTION CORP.03/06/1995
BIS—ISSUEDA.B.C. HORIZON HOME IMPROVEMENTS02/03/1995
1 project · most recent 06/03/2024
FiledStatusContractorScope
06/03/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/30/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/30/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/30/2024Energy Code Compliance InspectionsTOM PETERSENprogress
05/30/2024FinalTOM PETERSENprogress
05/30/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026S01058714-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S01058714-I1Open ↗
08/25/2026S01058714-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S01058714-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026S01058714-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S01058714-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01058714-I1Open ↗