← Back
Two stories - detached, small or mid-size
110-18 UNION HALL STREET
QUEENS · South Jamaica · BIN 4263611
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3AZoning
1,520 sfGross Floor Area
1Units
0 Open Violations
Two stories - detached, small or mid-size · Owner of record: WILMINGTON SAVINGS FUND SOCIETY, FSB · 3,060 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
Electrical
Roof1p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/26/2025$593K—— → —$390/sf building
01/11/2024$465K—Private party → WILMINGTON SAVINGS FUND SOCIETY, FSB$306/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC106/22/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272106/22/2026
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Violation (6)Special Inspection (5)
06/24/2026
Permit issued — Solar
Q01418942-I1-SL
06/22/2026
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF-MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01418942-I1
06/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
06/22/2026
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
06/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
06/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
06/18/2026
Special inspection requirement — Final
Walid Abdulla
10/03/2014
Violation issued (ECB, closed)
Construction
08/27/2014
Violation issued (ECB, closed)
Construction
06/02/2014
Violation issued (ECB, closed)
Unknown
05/07/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/16/2014
Violation issued (ECB, closed)
Unknown
02/16/2014
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC06/24/2026
1 project · most recent 06/22/2026
FiledStatusContractorScope
06/22/2026CompleteSUNRUN SOLAR ELECTL CORP—
1 project · most recent 06/22/2026
FiledStatusContractorScope
06/22/2026Signed-offSUNRUN INSTALLATION SVC10 panels, 4.5 kw, 210.2 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/22/2026Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
06/22/2026Air barrier - visual inspectionWalid Abdullaenergy_progress
06/18/2026Fire-Resistant Penetrations and JointsWalid Abdullaspecial
06/18/2026Energy Code Compliance InspectionsWalid Abdullaprogress
06/18/2026FinalWalid Abdullaprogress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026Q01418942-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01418942-I1Open ↗
08/25/2026Q01418942-I1Open ↗
08/25/2026Q01418942-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01418942-I1Open ↗
08/25/2026Q01418942-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026Q01418942-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026Q01418942-I1Open ↗