← Back
Two stories - detached, small or mid-size
110-24 177 STREET
QUEENS · St. Albans · BIN 4219138
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R3AZoning
1,280 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,000 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/19/2019$535K—177 STREET 2014 CORP → Private party$418/sf building
08/27/2015$200K—Private party → 177 STREET 2014 CORP.,$156/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC109/19/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HYTECH SOLAR INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244109/19/2024
Building Lifecycle
All (7)Filed (1)Permit Issued (1)Special Inspection (5)
09/30/2024
Permit issued — Solar
Q01066143-I1-SL
09/19/2024
Filed — Alteration
Q01066143-I1
06/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
06/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
06/13/2024
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
06/13/2024
Special inspection requirement — Final
NARESH MAHANGU
06/13/2024
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedHYTECH SOLAR09/30/2024
2 projects · most recent 05/05/2025
General Wiring
FiledStatusContractorScope
05/05/2025Permit IssuedGMJ ELECTRIC CORPGeneral Wiring
07/12/2024CompleteGMJ ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/13/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
06/13/2024Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
06/13/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
06/13/2024FinalNARESH MAHANGUprogress
06/13/2024Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01066143-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026Q01066143-I1Open ↗
08/22/2026Q01066143-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01066143-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026Q01066143-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01066143-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01066143-I1Open ↗