| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 11/02/2017 | $815K | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| A & T ENGINEERING, P.C. | 16 | 01/26/2024 |
| CHANDA ENGINEERING CONSULTANT PC | 1 | 01/13/2021 |
| Representative | Filings | Most Recent |
|---|---|---|
| S Y CONSULTING VIOLATIONS | 10 | 03/21/2026 |
| A T ENGINEERING P C | 8 | 03/21/2026 |
| TICKET BUSTERS | 2 | 03/21/2026 |
| ROGER BUILDING MANAGEMENT INC | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| EZ BUILDER CORP | General Contractor | 25 | 07/08/2026 |
| DZ CONSTRUCTION CORP | General Contractor | 4 | 07/08/2026 |
| RRP PLUMBING CORP | Fire Protection | 2 | 07/08/2026 |
| CHAMP PLUMBING & HTG CORP | Plumbing | 2 | 07/08/2026 |
| MPS PLUMBING & HEATING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| A & T DESIGN GROUP LLC | 1088 | 13 | 01/26/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Foundation | Signed-off | EZ BUILDER CORP | 01/11/2024 |
| DOB NOW | Curb Cut | Signed-off | EZ BUILDER CORP | 09/18/2023 |
| DOB NOW | Boiler Equipment | Signed-off | MPS PLUMBING & HEATING IN | 07/01/2023 |
| DOB NOW | Plumbing | Signed-off | CHAMP PLUMBING & HTG CORP | 06/15/2023 |
| DOB NOW | Sprinklers | Signed-off | RALPH W. LANDOLFI JR. | 05/01/2023 |
| DOB NOW | Plumbing | Signed-off | RALPH W. LANDOLFI JR. | 09/08/2022 |
| DOB NOW | Sprinklers | Signed-off | CHAMP PLUMBING & HTG CORP | 07/22/2022 |
| DOB NOW | General Construction | Signed-off | EZ BUILDER CORP | 06/24/2022 |
| DOB NOW | General Construction | Permit Issued | EZ BUILDER CORP | 06/24/2022 |
| DOB NOW | Earth Work | Signed-off | EZ BUILDER CORP | 05/28/2022 |
| DOB NOW | General Construction | Permit Issued | EZ BUILDER CORP | 05/27/2022 |
| DOB NOW | Support of Excavation | Signed-off | EZ BUILDER CORP | 05/26/2022 |
| DOB NOW | Mechanical Systems | Signed-off | EZ BUILDER CORP | 05/26/2022 |
| DOB NOW | Construction Fence | Signed-off | EZ BUILDER CORP | 05/26/2022 |
| DOB NOW | Mechanical Systems | Signed-off | EZ BUILDER CORP | 04/27/2022 |
| DOB NOW | Construction Fence | Signed-off | EZ BUILDER CORP | 03/29/2022 |
| DOB NOW | Structural | Signed-off | EZ BUILDER CORP | 03/10/2022 |
| DOB NOW | General Construction | Permit Issued | EZ BUILDER CORP | 03/03/2022 |
| DOB NOW | Support of Excavation | Signed-off | EZ BUILDER CORP | 02/17/2022 |
| DOB NOW | Construction Fence | Signed-off | DZ CONSTRUCTION CORP | 03/11/2021 |
| DOB NOW | Construction Fence | Signed-off | DZ CONSTRUCTION CORP | 01/27/2021 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/26/2024 | Signed-off | EZ BUILDER CORP | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Heating A.O. Smith BPD-80 75,000 BTU · Water Heater ×4 Weil-Mclain CGA-3 70,000 BTU · Boiler ×4 Ventilation Greenheck SP-B110 150 CFM · Exhaust Fan ×11 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/26/2024 | Signed-off | MPS PLUMBING & HEATING IN | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/07/2022 | Complete | AL-LECTRIC ELECT'L CONTRG | General Wiring |
| 05/31/2022 | Complete | AL-LECTRIC ELECT'L CONTRG | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/26/2024 | Signed-off | EZ BUILDER CORP | Steel, Concrete, Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/28/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 08/12/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 08/05/2024 | Pass-Final Construction Permit Withdrawal | Pass | View ↗ |
| 03/20/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/31/2024 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 01/26/2024 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 09/29/2023 | Pass-Final Boiler Equipment Inspection | Pass | View ↗ |
| 09/21/2023 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 07/10/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 07/06/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 06/26/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/07/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 10/07/2022 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 10/07/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/25/2022 | Fail-Final House Connection | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/11/2024 | Subgrade Inspections | ROBERT LIN | special |
| 01/11/2024 | Fire-Resistance Rated Construction | ROBERT LIN | progress |
| 01/11/2024 | Insulation placement and R values | ROBERT LIN | energy_progress |
| 01/11/2024 | Protection of exposed foundation insulation | ROBERT LIN | energy_progress |
| 01/11/2024 | Lighting controls | ROBERT LIN | energy_progress |
| 01/11/2024 | Exterior lighting power | ROBERT LIN | energy_progress |
| 01/11/2024 | Air barrier - visual inspection | ROBERT LIN | energy_progress |
| 01/11/2024 | Fenestration and door U-factor and product ratings | ROBERT LIN | energy_progress |
| 01/11/2024 | Lighting in dwelling units | ROBERT LIN | energy_progress |
| 01/11/2024 | Masonry | ROBERT LIN | special |
| 01/11/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | ROBERT LIN | special |
| 01/11/2024 | Energy Code Compliance Inspections | ROBERT LIN | progress |
| 01/11/2024 | Preliminary | ROBERT LIN | progress |
| 01/11/2024 | Interior lighting power | ROBERT LIN | energy_progress |
| 01/11/2024 | Fire-Resistant Penetrations and Joints | ROBERT LIN | special |
| 01/11/2024 | Concrete - Cast-In-Place | ROBERT LIN | special |
| 01/11/2024 | Chimneys and vents | ROBERT LIN | special |
| 01/11/2024 | Fenestration areas | ROBERT LIN | energy_progress |
| 01/11/2024 | HVAC-R and service water piping design and insulation | ROBERT LIN | energy_progress |
| 01/11/2024 | Fenestration air leakage | ROBERT LIN | energy_progress |
| 01/11/2024 | Electrical motors and elevators | ROBERT LIN | energy_progress |
| 01/11/2024 | Maintenance information | ROBERT LIN | energy_progress |
| 01/11/2024 | Metering | ROBERT LIN | energy_progress |
| 09/20/2023 | Heating Systems | ROBERT LIN | special |
| 09/20/2023 | HVAC-R and service water heating equipment | ROBERT LIN | energy_progress |