← Back
BuildNYC
Large suburban residence
110-50 69TH AVENUE
QUEENS · Forest Hills · BIN 4052479
💬 Discuss this project
1935Year Built
2Stories
A3Building Class
R1-2AZoning
3,806 sfGross Floor Area
1Units
Large suburban residence · 7,500 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofSignage1p · 1 filing · 6 docs
Attic79p · 1 filing · 20 docs
Floor 293p · 1 filing · 20 docs
Floor 192p · 1 filing · 20 docs
Cellar91p · 1 filing · 20 docs
Site & exteriorTemporary construction fence installation1p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/09/2022$2.7M—MGPRT LLC → Private party$705/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Boris Balkhiyev, PE110/17/2025
AA Building & Inspection Service1007/16/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Dmconsulting68602003/21/2026
Advanced Solar Solutions103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Giron ContractingGeneral Contractor1603/21/2026
Giron ContractingScaffold407/08/2026
Advanced Solar SolutionsGeneral Contractor203/21/2026
Raymond's Plumbing & HeatingPlumbing207/08/2026
Brandl ElectricElectrical103/22/2026
Nas ElectricElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MB Inspections8703110/17/2025
HRF Services5616907/16/2025
Building Lifecycle
All (79)Filed (11)Permit Issued (14)Signed Off (3)Inspection (3)Objection (18)Special Inspection (30)
03/05/2026
Signed off — Alteration
Q01302698-I1
12/02/2025
Permit issued — Solar
Q01302698-I1-SL
10/17/2025
Filed — Alteration
Q01302698-I1
10/14/2025
Special inspection requirement — Energy Code Compliance Inspections
BORIS BALKHIYEV
10/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
BORIS BALKHIYEV
10/14/2025
Special inspection requirement — Air barrier - visual inspection
BORIS BALKHIYEV
10/14/2025
Special inspection requirement — Final
BORIS BALKHIYEV
07/16/2025
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P8
07/16/2025
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
07/16/2025
Special inspection requirement — Interior lighting power
FAHAD FATEH
07/16/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
07/16/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
07/16/2025
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
07/16/2025
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
07/16/2025
Special inspection requirement — Final
FAHAD FATEH
07/16/2025
Special inspection requirement — Permanent certificate
FAHAD FATEH
07/16/2025
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
07/16/2025
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
07/16/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
07/16/2025
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
07/16/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
FAHAD FATEH
07/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
07/16/2025
Special inspection requirement — Subgrade Inspections
FAHAD FATEH
07/16/2025
Special inspection requirement — Mechanical Systems
FAHAD FATEH
07/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
07/16/2025
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
07/16/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
FAHAD FATEH
07/16/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
07/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
07/16/2025
Special inspection requirement — Footing and Foundation
FAHAD FATEH
07/16/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
07/16/2025
Special inspection requirement — Fireplaces
FAHAD FATEH
07/16/2025
Special inspection requirement — Air barrier — testing
FAHAD FATEH
07/16/2025
Special inspection requirement — Lighting controls
FAHAD FATEH
04/26/2025
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P7
04/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/19/2024
Signed off — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-S1
10/15/2024
Signed off — Alteration
HEREWITH FILE ALTERATION IN ORDER TO ERECT TEMPORARY CONSTRUCTION PLYWOOD FENCE.
Q00722084-I1
10/09/2024
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P6
04/19/2024
Objection resolved — Addressed
04/18/2024
Objection raised — Structural
04/10/2024
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P5
12/27/2023
Permit issued — Plumbing
Q00722088-S1-PL
10/26/2023
Permit issued — Mechanical Systems
Q00722088-I1-GC
10/25/2023
Permit issued — Construction Fence
Q00722084-I1-FN
07/17/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/28/2023
Permit issued — Mechanical Systems
Q00722088-I1-MS
06/27/2023
Permit issued — Earth Work
Q00722088-I1-FO-EA
06/27/2023
Permit issued — Construction Fence
Q00722084-I1-FN
06/26/2023
Permit issued — Earth Work
Q00722088-I1-GC
06/14/2023
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P2
06/13/2023
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P4
02/14/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/19/2022
Permit issued — Plumbing
Q00722088-S1-PL
09/13/2022
Objection resolved — Addressed
09/12/2022
Objection raised — Scope
09/04/2022
Filed — Alteration CO
HEREWITH FILE ALTERATION CO IN ORDER TO DO A VERTICAL EXTENSION TO AN EXISTING ONE FAMILY DWELLING INCLUDING MECHANICAL AND OT WORK TYPES. TO DO INTERIOR RENOVATIONS. FOUNDATION AND STRUCTURAL WORK TYPE PART OF THIS APPLICATION, AND TO OBTAIN A NEW C OF O
Q00722088-P1
07/06/2022
Permit issued — Structural
Q00722088-I1-FO-EA
07/05/2022
Permit issued — Mechanical Systems
Q00722088-I1-ST
07/05/2022
Permit issued — Structural
Q00722088-I1-MS
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offAdvanced Solar Solutions12/02/2025
DOB NOWPlumbingSigned-offRaymond's Plumbing & Heating12/27/2023
DOB NOWMechanical SystemsPermit IssuedGiron Contracting10/26/2023
DOB NOWConstruction FenceSigned-offGiron Contracting10/25/2023
DOB NOWMechanical SystemsSigned-offGiron Contracting06/28/2023
DOB NOWEarth WorkSigned-offGiron Contracting06/27/2023
DOB NOWConstruction FenceSigned-offGiron Contracting06/27/2023
DOB NOWEarth WorkPermit IssuedGiron Contracting06/26/2023
DOB NOWPlumbingSigned-offRaymond's Plumbing & Heating09/19/2022
DOB NOWStructuralSigned-offGiron Contracting07/06/2022
DOB NOWMechanical SystemsSigned-offGiron Contracting07/05/2022
DOB NOWStructuralSigned-offGiron Contracting07/05/2022
DOB NOWEarth WorkPermit IssuedGiron Contracting06/23/2022
DOB NOWConstruction FenceSigned-offGiron Contracting06/02/2022
1 project · most recent 07/16/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2025Permit IssuedGiron ContractingAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric M4H36W06060615-B 36,000 BTU ×12
Heating
Mitsubishi Electric M4H36W06060615-B 38,000 BTU ×8
Ventilation
Mitsubishi Electric M4H36W06060615-B 400,000 BTU ×8
1 project · most recent 07/16/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/16/2025Signed-offRaymond's Plumbing & HeatingGas, Storm, Water/Sanitary
2 projects · most recent 10/16/2025
General Wiring Lighting
FiledStatusContractorScope
10/16/2025CompleteBrandl Electric1 meters, 1 new_meters
06/11/2025CompleteNas ElectricGeneral Wiring, Lighting
1 project · most recent 07/16/2025
Steel Wood
FiledStatusContractorScope
07/16/2025Signed-offRaymond's Plumbing & HeatingSteel, Wood
1 project · most recent 07/16/2025
Earthwork
FiledStatusContractorScope
07/16/2025Signed-offRaymond's Plumbing & HeatingEarthwork
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/17/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/14/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
10/14/2025Fire-Resistant Penetrations and JointsBORIS BALKHIYEVspecial
10/14/2025Air barrier - visual inspectionBORIS BALKHIYEVenergy_progress
10/14/2025FinalBORIS BALKHIYEVprogress
10/14/2025Energy Code Compliance InspectionsBORIS BALKHIYEVprogress
07/16/2025Structural Steel - High Strength BoltingFAHAD FATEHspecial
07/16/2025Fenestration air leakageFAHAD FATEHenergy_progress
07/16/2025Exterior lighting powerFAHAD FATEHenergy_progress
07/16/2025HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
07/16/2025Protection of exposed foundation insulationFAHAD FATEHenergy_progress
07/16/2025Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
07/16/2025Lighting controlsFAHAD FATEHenergy_progress
07/16/2025HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
07/16/2025Interior lighting powerFAHAD FATEHenergy_progress
07/16/2025Air barrier - visual inspectionFAHAD FATEHenergy_progress
07/16/2025Air barrier — testing FAHAD FATEHenergy_progress
07/16/2025HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
07/16/2025FireplacesFAHAD FATEHenergy_progress
07/16/2025Fenestration areasFAHAD FATEHenergy_progress
07/16/2025Insulation placement and R valuesFAHAD FATEHenergy_progress
07/16/2025Permanent certificateFAHAD FATEHenergy_progress
07/16/2025Footing and FoundationFAHAD FATEHprogress
07/16/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
07/16/2025FinalFAHAD FATEHprogress
07/16/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
07/16/2025Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
Latest 25 of 150.
▾Documents — 119 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/26/2026Q00722084-I1Request digital key ↗
08/21/2026Q00722088-S1Request digital key ↗
08/21/2026Q00722088-P8Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
03/22/2024400449010Open ↗
03/07/2024400449010Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram6
08/13/2026Q00722088-I1Open ↗
08/13/2026Q00722088-P7Open ↗
08/13/2026Q00722088-P5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00722088-I1Open ↗
▸Seals & Professional Certifications48
▸DOB NOWSpecial Inspector Seal & Signature23
09/28/2026Q00722088-P5Open ↗
09/28/2026Q00722088-P5Open ↗
09/28/2026Q00722088-P5Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/28/2026Q00722088-P5Open ↗
09/28/2026Q00722088-P5Open ↗
09/02/2026Q00722088-P7Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/13/2026Q00722088-S1Open ↗
08/13/2026Q00722088-P4Open ↗
08/13/2026Q00722084-I1Open ↗
Showing 3 of 11 on file for this type
▸Safety & Tenant Protection6
▸DOB NOWStreet Tree Checklist6
08/13/2026Q00722088-I1Open ↗
08/13/2026Q00722088-P1Open ↗
08/13/2026Q00722088-P5Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/13/2026Q00722088-I1Open ↗
08/13/2026Q00722088-P5Open ↗
08/13/2026Q00722088-S1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00722088-I1Open ↗
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT6
08/13/2026Q00722088-P4Open ↗
08/13/2026Q00722088-P5Open ↗
08/13/2026Q00722088-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00722088-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00722088-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01302698-I1Open ↗
▸Other Documents26
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/13/2026Q00722088-P7Open ↗
08/13/2026Q00722088-P8Open ↗
08/13/2026Q00722088-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlot Diagram6
08/13/2026Q00722088-P1Open ↗
08/13/2026Q00722088-P4Open ↗
08/13/2026Q00722088-P5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification6
08/13/2026Q00722088-P1Open ↗
08/13/2026Q00722088-P4Open ↗
08/13/2026Q00722088-P8Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSite Survey: Initial6
08/13/2026Q00722088-P4Open ↗
08/13/2026Q00722088-P1Open ↗
08/13/2026Q00722088-P5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00722088-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00722088-I1Open ↗