← Back
Two stories - detached, small or mid-size
110-51 173 STREET
QUEENS · St. Albans · BIN 4219023
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R3AZoning
2,329 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: 173 STREET CAPITAL LLC · 4,000 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof3p · 1 filing · 14 docs
Floor 216p · 1 filing · 20 docs
Floor 116p · 1 filing · 20 docs
Cellar19p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PEEPS SERVICES203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/16/2025$1.4M—— → —$586/sf building
08/23/2019$360K—— → —$155/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D&E BUILD EVERGREEN INC.1011/06/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC1803/21/2026
RS CONST & EXP SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B36 SERVICES INCGeneral Contractor603/21/2026
PEEPS SERVICES INCGeneral Contractor604/09/2026
RONEY ELECTRIC INCElectrical103/22/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D&E BUILD EVERGREEN I9342711/06/2025
TRIANGLE INSPECTION & TES7495107/23/2021
Building Lifecycle
All (61)Filed (9)Permit Issued (7)Signed Off (4)Violation (2)Inspection (5)Objection (4)Special Inspection (30)
11/28/2025
Signed off — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-S1
11/28/2025
Signed off — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q00482763-I1.
Q00561670-I1
11/28/2025
Signed off — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-S2
11/28/2025
Signed off — Alteration
Q00561631-I1
11/28/2025
Special inspection requirement — Metering
Danny Chen
11/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Danny Chen
11/28/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Danny Chen
11/28/2025
Special inspection requirement — Footing and Foundation
Danny Chen
11/28/2025
Special inspection requirement — Air barrier - visual inspection
Danny Chen
11/28/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Danny Chen
11/28/2025
Special inspection requirement — Maintenance information
Danny Chen
11/28/2025
Special inspection requirement — Fenestration areas
Danny Chen
11/28/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
11/28/2025
Special inspection requirement — Masonry
Danny Chen
11/28/2025
Special inspection requirement — Interior lighting power
Danny Chen
11/28/2025
Special inspection requirement — Insulation placement and R values
Danny Chen
11/28/2025
Special inspection requirement — Fenestration air leakage
Danny Chen
11/28/2025
Special inspection requirement — Electric vehicle service equipment requirements
Danny Chen
11/28/2025
Special inspection requirement — Concrete - Cast-In-Place
Danny Chen
11/28/2025
Special inspection requirement — Fire-Resistance Rated Construction
Danny Chen
11/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
11/28/2025
Special inspection requirement — Permanent certificate
Danny Chen
11/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
11/28/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Danny Chen
11/28/2025
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Danny Chen
11/28/2025
Special inspection requirement — Subgrade Inspections
Danny Chen
11/28/2025
Special inspection requirement — Final
PETER CHO
11/10/2025
Special inspection requirement — Energy Code Compliance Inspections
Danny Chen
11/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Danny Chen
11/10/2025
Special inspection requirement — Final
PETER CHO
11/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
Danny Chen
11/10/2025
Special inspection requirement — Mechanical Systems
Danny Chen
11/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Danny Chen
11/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Danny Chen
11/06/2025
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-P4
11/03/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/27/2025
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-P3
07/16/2025
Violation issued (ECB, closed)
Construction
07/16/2025
Violation issued (ECB, closed)
Construction
05/29/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/29/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/29/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/29/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/12/2025
Permit issued — Plumbing
Q00561670-I1-PL
04/03/2025
Permit issued — Construction Fence
Q00561631-I1-FN
04/02/2025
Permit issued — Structural
Q00482763-S2-ST
04/02/2025
Permit issued — General Construction
Q00482763-I1-GC-CX
04/02/2025
Permit issued — Mechanical Systems
Q00482763-S1-MS
03/25/2025
Permit issued — General Construction
Q00482763-I1-GC-CX
03/19/2025
Permit issued — Construction Fence
Q00561631-I1-FN
03/06/2025
Objection resolved — Addressed
02/27/2025
Objection raised — Energy
02/27/2025
Objection resolved — Addressed
02/26/2025
Objection raised — Scope
02/17/2025
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-S1
02/17/2025
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-S2
02/17/2025
Filed — Alteration CO
FILED HEREWITH MECHANICAL WORK TYPE IN CONJUNCTION WITH DOB NOW APPLICATION #Q00482763-I1
Q00482763-P1
02/17/2025
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q00482763-I1.
Q00561670-P1
07/23/2021
Filed — Alteration
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q00482763-I1.
Q00561670-I1
07/23/2021
Filed — Alteration
Q00561631-I1
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR05/12/2025
DOB NOWConstruction FenceSigned-offPEEPS SERVICES INC04/03/2025
DOB NOWStructuralSigned-offPEEPS SERVICES INC04/02/2025
DOB NOWGeneral ConstructionPermit IssuedPEEPS SERVICES INC04/02/2025
DOB NOWMechanical SystemsSigned-offPEEPS SERVICES INC04/02/2025
DOB NOWGeneral ConstructionPermit IssuedB36 SERVICES INC03/25/2025
DOB NOWConstruction FenceSigned-offB36 SERVICES INC03/19/2025
1 project · most recent 11/06/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/06/2025Signed-offPEEPS SERVICES INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Goodman GLXS3BN3610AA 36,000 BTU · Condensing Unit ×2
GLXS3BN6010AA 60,000 BTU · Condensing Unit ×2
Heating
Goodman GR9S800603BNAA 60,000 BTU · Furnace ×2
GR9S921005CNAA 100,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10
Samsung ME16A4021AS 900 CFM · Kitchen Exhaust ×4
1 project · most recent 09/29/2025
General Wiring
FiledStatusContractorScope
09/29/2025CompleteRONEY ELECTRIC INCGeneral Wiring
1 project · most recent 11/06/2025
Wood
FiledStatusContractorScope
11/06/2025Signed-offPEEPS SERVICES INCWood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/29/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/29/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/29/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 135
DateRequirementInspectorRole
11/28/2025Fire-Resistant Penetrations and JointsDanny Chenspecial
11/28/2025MeteringDanny Chenenergy_progress
11/28/2025HVAC-R and service water piping design and insulationDanny Chenenergy_progress
11/28/2025Fenestration areasDanny Chenenergy_progress
11/28/2025Permanent certificateDanny Chenenergy_progress
11/28/2025Maintenance informationDanny Chenenergy_progress
11/28/2025Air barrier - visual inspectionDanny Chenenergy_progress
11/28/2025Fenestration air leakageDanny Chenenergy_progress
11/28/2025Interior lighting powerDanny Chenenergy_progress
11/28/2025Insulation placement and R valuesDanny Chenenergy_progress
11/28/2025Electric vehicle service equipment requirementsDanny Chenenergy_progress
11/28/2025Fenestration and door U-factor and product ratingsDanny Chenenergy_progress
11/28/2025FinalPETER CHOprogress
11/28/2025Energy Code Compliance InspectionsDanny Chenprogress
11/28/2025Fire-Resistance Rated ConstructionDanny Chenprogress
11/28/2025Footing and FoundationDanny Chenprogress
11/28/2025MasonryDanny Chenspecial
11/28/2025Subgrade InspectionsDanny Chenspecial
11/28/2025Excavations - Sheeting, Shoring, and BracingDanny Chenspecial
11/28/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
11/28/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationDanny Chenspecial
11/28/2025Structural Stability – Alterations of existing buildingsDanny Chenspecial
11/28/2025Concrete - Cast-In-PlaceDanny Chenspecial
11/10/2025Structural Stability – Alterations of existing buildingsDanny Chenspecial
11/10/2025HVAC-R and service water piping design and insulationDanny Chenenergy_progress
Latest 25 of 135.
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/27/2026Q00561631-I1Request digital key ↗
08/27/2026Q00561670-I1Request digital key ↗
08/18/2026Q00482763-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram4
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
08/18/2026Q00482763-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00482763-I1Open ↗
▸Seals & Professional Certifications41
▸DOB NOWProgress Inspector Seal & Signature18
09/24/2026Q00482763-S2Open ↗
09/24/2026Q00482763-S2Open ↗
08/28/2026Q00482763-S1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/24/2026Q00482763-S2Open ↗
08/28/2026Q00482763-S1Open ↗
08/28/2026Q00482763-S1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/27/2026Q00561631-I1Open ↗
08/27/2026Q00561670-P1Open ↗
08/27/2026Q00561670-I1Open ↗
Showing 3 of 10 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/27/2026Q00561670-I1Open ↗
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00482763-I1Open ↗
08/13/2026Q00561670-I1Open ↗
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT6
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
08/18/2026Q00482763-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00482763-I1Open ↗
08/13/2026Q00561670-I1Open ↗
▸Other Documents13
▸DOB NOWSite Survey: Initial4
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
08/18/2026Q00482763-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
08/18/2026Q00482763-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/18/2026Q00482763-I1Open ↗
08/18/2026Q00482763-P1Open ↗
08/18/2026Q00482763-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026Q00482763-I1Open ↗