← Back
Two stories - detached, small or mid-size
110-55 70 ROAD
QUEENS · BIN 4052537
💬 Discuss this project
1945Year Built
1.5Stories
A1Building Class
R1-2AZoning
2,494 sfGross Floor Area
1Units
0 Open Violations
Two stories - detached, small or mid-size · 4,500 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Floor 214p · 1 filing · 20 docs
Floor 116p · 1 filing · 20 docs
Cellar18p · 1 filing · 20 docs
1 job · most recent 04/03/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/03/2026Permit IssuedNYC BUILDING SOLUTIONS COAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric SPLIT-SYSTEM HEAT PUMP. (MXZ-3C30NA3) 2 UNITS, (MXZ-4C36NA3) 2 UNITS 42,000 BTU · Vrf Outdoor ×2
Goodman ASPT47C14 42,000 BTU · Fan Coil Indoor ×3
Heating
Mitsubishi Electric SEZ-KD12NA4, MLZ-KP12NA, MLZ-KP12NA, MLZ-KP18NA, MLZ-KP18NA 48,000 BTU · Condensing Unit ×2
Goodman GSZC160481 48,000 BTU · Condensing Unit ×3
Ventilation
Rangemaster RM6030-A 50 CFM · Exhaust Fan ×6
1 job · most recent 04/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/03/2026Signed-offVMC PLUMBING & HEATING INGas, Water/Sanitary
2 jobs · most recent 10/27/2022
General Wiring
FiledStatusContractorScope
10/27/2022CompleteWCK ELECTRIC CORP.General Wiring
01/07/2022CompleteK.A.B. ELECTRIC CORPGeneral Wiring
1 job · most recent 04/03/2026
Steel Wood
FiledStatusContractorScope
04/03/2026Signed-offVMC PLUMBING & HEATING INSteel, Wood
1 job · most recent 04/03/2026
Fence
FiledStatusContractorScope
04/03/2026Signed-offVMC PLUMBING & HEATING INFence
Building Lifecycle
All (76)Filed (10)Permit Issued (5)Signed Off (2)Violation (2)Inspection (7)Objection (20)Special Inspection (30)
04/03/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-A2
04/02/2026
Special inspection requirement — Interior lighting power
JEFFREY BELL
04/02/2026
Special inspection requirement — Heating Systems
DOYUN KIM
04/02/2026
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
04/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
JEFFREY BELL
04/02/2026
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
DOYUN KIM
04/02/2026
Special inspection requirement — Final
DOYUN KIM
04/02/2026
Special inspection requirement — Structural Steel - Details
DOYUN KIM
04/02/2026
Special inspection requirement — Subgrade Inspections
DOYUN KIM
04/02/2026
Special inspection requirement — Duct leakage testing, insulation and design
JEFFREY BELL
04/02/2026
Special inspection requirement — Ventilation and air distribution system
JEFFREY BELL
04/02/2026
Special inspection requirement — Fenestration air leakage
JEFFREY BELL
04/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
04/02/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
DOYUN KIM
04/02/2026
Special inspection requirement — Air barrier - visual inspection
JEFFREY BELL
04/02/2026
Special inspection requirement — Mechanical Systems
DOYUN KIM
04/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
DOYUN KIM
04/02/2026
Special inspection requirement — Structural Steel - High Strength Bolting
DOYUN KIM
04/02/2026
Special inspection requirement — Structural Steel - Welding
DOYUN KIM
04/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
DOYUN KIM
04/02/2026
Special inspection requirement — Structural Wood Frame
DOYUN KIM
04/02/2026
Special inspection requirement — Insulation placement and R values
JEFFREY BELL
04/02/2026
Special inspection requirement — Fireplaces
JEFFREY BELL
04/02/2026
Special inspection requirement — Demolition
DOYUN KIM
03/31/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/04/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
04/08/2024
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-S2
04/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
DOYUN KIM
01/02/2024
Special inspection requirement — Structural Steel - Welding
DOYUN KIM
01/02/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
01/02/2024
Special inspection requirement — Structural Steel - Details
DOYUN KIM
01/02/2024
Special inspection requirement — Structural Wood Frame
DOYUN KIM
01/02/2024
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
DOYUN KIM
01/02/2024
Special inspection requirement — Final
DOYUN KIM
12/17/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-P9
12/17/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-A1
08/04/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/01/2023
Permit issued — Plumbing
Q00595554-S2-PL
05/16/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-P8
05/16/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-P6
01/16/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-P1
01/16/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-P5
01/10/2023
Permit issued — Structural
Q00595554-I1-GC-CX
01/06/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-S1
08/06/2022
Violation issued (ECB, closed)
Construction
08/06/2022
Violation issued (ECB, closed)
Construction
06/16/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/01/2022
Permit issued — Plumbing
Q00595554-S2-PL
03/21/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-S2
01/25/2022
Permit issued — Structural
Q00595554-I1-GC-CX
12/01/2021
Permit issued — Construction Fence
Q00595554-S1-FN
11/03/2021
Objection raised — Mechanical
11/03/2021
Objection resolved — Addressed
11/03/2021
Objection raised — Scope
11/03/2021
Objection resolved — Addressed
11/02/2021
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED VERTICAL EXTENSION AND GUT RENOVATION TO THE EXISTING 1 1/2 SINGLE FAMILY HOUSE. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
Q00595554-S1
09/30/2021
Objection raised — Zoning
Latest 60 of 76 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BUILDING SOLUTIONS CO NYC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/23/2021$1.4M—Private party → Private party$578/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.1004/03/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FOCAL POINT DESIGN & CONST. INC.1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDING SOLUTIONS COGeneral Contractor507/08/2026
VMC PLUMBING & HEATING INPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415504/03/2026
S&S CONCRETE & SOIL TESTI1008412/17/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offM. SPINELLI PLB & HTG INC08/01/2023
DOB NOWStructuralPermit IssuedNYC BUILDING SOLUTIONS CO01/10/2023
DOB NOWPlumbingSigned-offM. SPINELLI PLB & HTG INC06/01/2022
DOB NOWStructuralPermit IssuedNYC BUILDING SOLUTIONS CO01/25/2022
DOB NOWConstruction FenceSigned-offNYC BUILDING SOLUTIONS CO12/01/2021
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
03/31/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/04/2026Fail-Final CND-Occupancy InspectionFailView ↗
04/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/04/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/09/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 118
DateRequirementInspectorRole
04/02/2026FinalDOYUN KIMprogress
04/02/2026Air barrier - visual inspectionJEFFREY BELLenergy_progress
04/02/2026Fenestration air leakageJEFFREY BELLenergy_progress
04/02/2026Interior lighting powerJEFFREY BELLenergy_progress
04/02/2026Fenestration and door U-factor and product ratingsJEFFREY BELLenergy_progress
04/02/2026Ventilation and air distribution systemJEFFREY BELLenergy_progress
04/02/2026FireplacesJEFFREY BELLenergy_progress
04/02/2026Insulation placement and R valuesJEFFREY BELLenergy_progress
04/02/2026Duct leakage testing, insulation and designJEFFREY BELLenergy_progress
04/02/2026Structural Wood FrameDOYUN KIMprogress
04/02/2026Fire-Resistance Rated ConstructionDOYUN KIMprogress
04/02/2026Energy Code Compliance InspectionsDOYUN KIMprogress
04/02/2026Subgrade InspectionsDOYUN KIMspecial
04/02/2026Structural Steel - WeldingDOYUN KIMspecial
04/02/2026Structural Steel - High Strength BoltingDOYUN KIMspecial
04/02/2026Structural Steel - DetailsDOYUN KIMspecial
04/02/2026Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
04/02/2026Mechanical SystemsDOYUN KIMspecial
04/02/2026Heating SystemsDOYUN KIMspecial
04/02/2026Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)DOYUN KIMspecial
04/02/2026Fire-Resistant Penetrations and JointsDOYUN KIMspecial
04/02/2026Exterior Insulation and Finish Systems (EIFS)DOYUN KIMspecial
04/02/2026DemolitionDOYUN KIMspecial
01/02/2024Fenestration and door U-factor and product ratingsJEFFREY BELLenergy_progress
01/02/2024Mechanical SystemsDOYUN KIMspecial
Latest 25 of 118.
▾Documents — 80 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/23/2026Q00595554-S2Request digital key ↗
08/23/2026Q00595554-P1Request digital key ↗
08/23/2026Q00595554-P5Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram5
08/13/2026Q00595554-P9Open ↗
08/13/2026Q00595554-I1Open ↗
08/13/2026Q00595554-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00595554-I1Open ↗
▸Seals & Professional Certifications38
▸DOB NOWSpecial Inspector Seal & Signature18
09/23/2026Q00595554-A1Open ↗
08/26/2026Q00595554-P8Open ↗
08/25/2026Q00595554-A2Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/23/2026Q00595554-S2Open ↗
08/23/2026Q00595554-P5Open ↗
08/23/2026Q00595554-P6Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/25/2026Q00595554-A2Open ↗
08/25/2026Q00595554-A2Open ↗
08/25/2026Q00595554-P6Open ↗
Showing 3 of 10 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/23/2026Q00595554-S2Open ↗
08/23/2026Q00595554-P5Open ↗
08/23/2026Q00595554-P8Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00595554-I1Open ↗
▸Other Documents16
▸DOB NOWSite Survey: Initial5
08/13/2026Q00595554-A2Open ↗
08/13/2026Q00595554-P9Open ↗
08/13/2026Q00595554-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026Q00595554-P6Open ↗
08/13/2026Q00595554-A2Open ↗
08/13/2026Q00595554-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification5
08/23/2026Q00595554-P1Open ↗
08/23/2026Q00595554-P6Open ↗
08/23/2026Q00595554-P9Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWFinal Survey1
08/13/2026Q00595554-I1Open ↗