ECB08/06/2026CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION DEVICE IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION AS REQUIRED BY APPENDIX K. PROVIDE A FUNCTIONAL TWO-WAY EMERGENCY COMMUNICATION SYSTEM CONNECTED TO A CON$625 due
DOB03/06/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER .NOTED:OBSERVED AT REAR EXPO 3 FROM 1ST TO 2ND FLOOR FIRE ESCAPE MISSING 2 TREADS STEP . SOME TREADS STEPS ARE DETACHED FROM STRINGER DUE TO METAL CORROSION .FIRE SCAPE IN POOR CONDITION AT DIFFERENT LOCATION OR STEPS LEVEL .CREATED FALL HAZARD CONDITION TO OCCUPANTS .
HPD11/25/2024§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 8, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD11/20/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 10, 10th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD03/31/2024§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT BASEMENT
HPD06/05/2019§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING MINIMUM OF 100 WATTS AS REQUIRED(LIGHT FIXTURE(S) PRESENT). AT FRONT AREAWAY
HPD11/16/2015SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCES AND ASSEMBLY AT LOWER SASH WINDOW IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD09/08/2014SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH LOCK ON SOUTH UPPER AND LOWER WINDOW (FIRE ESCAPE WINDOW) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD09/08/2014SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CIRCUIT BREAKER PANEL AT WOOD CABINET AT WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD09/08/2014SECTION 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK MISSING VENTILATION SYSTEM AT WATER CLOSET COMPARTMENT IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD09/08/2014SECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT EXPOSED WEST BRICK BRICK WALL WITH CRACKED LINE APPROX. 6 FEET LONG FROM CEILING TO CENTER WALL LEVEL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD09/08/2014SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD09/08/2014SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH WALL APPROX. 1 SQUARE FEET IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3RDFLR, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
HPD03/18/2010SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PAINTED SPRINKLER HEADS AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT EAST
DOB10/29/2007V-DOB VIOLATION - ACTIVE
HPD01/15/2004SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH IN THE 5th ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY
HPD09/26/2003SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FRAME, AT DOOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY
HPD09/26/2003SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM, BLDG. ENTRANCE TO , 2nd STORY, APARTMENT
DOB12/17/1991VP-VIOLATION UNSERVED ECB-ACTIVE
DOB11/22/1989VP-VIOLATION UNSERVED ECB-ACTIVE