← Back
Co-op within a condominium
Forester Condominium
111-01 QUEENS BOULEVARD · BIN 4307915
💬 Discuss this project
1966Year Built
14Stories
R9Building Class
R7-1Zoning
225,529 sfGross Floor Area
120Units
LL97 CoveredRent Stabilized1 Open Violation ▸FISP: SWARMPFDNY Report ↗
Co-op within a condominium · Owner of record: FORESTER CONDOMINIUM · 13,327 sf lot · 16.92 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction5p · 2 filings · 19 docs
Floor 91p · 1 filing · 6 docs
Floor 82p · 1 filing · 7 docs
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 210p · 3 filings · 18 docs
Floor 1Under Construction5p · 4 filings · 20 docs
CellarUnder Construction13p · 2 filings · 20 docs
Sub-Cellar5p · 3 filings · 20 docs
4 jobs · most recent 12/10/2025
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/10/2025Signed-offADI CONTRACTING LLCAir Conditioning Systems, Heating Systems
Cooling
Daikin FXMQ36TBVJU 36,000 BTU · Vrf Indoor ×4
FXMQ12TBVJU 13,000 BTU · Vrf Indoor ×2
FXMQ18TBVJU 19,000 BTU · Vrf Indoor ×2
FXMQ48TBVJU 42,000 BTU · Vrf Indoor ×2
REYQ264AATJB (A - REYQ120AATJB, B- REYQ144AATJB) 264,000 BTU · Condensing Unit ×2
FTKF24BVJU9 22,000 BTU · Split System ×1
RKF24BVJU9 22,000 BTU · Condensing Unit ×1
Heating
Daikin FXMQ36TBVJU 40,000 BTU · Vrf Indoor ×4
FXMQ18TBVJU 21,500 BTU · Vrf Indoor ×2
FXMQ48TBVJU 47,000 BTU · Vrf Indoor ×2
10/30/2025Signed-offHUDSON CONTRACTING GROUPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUZ-AK36NLHZ 3 tons · Condensing Unit ×1
Ventilation
Barry Blower C36JVS 210 CFM · Exhaust Fan ×3
07/11/2025Permit IssuedALMA DESIGN INCAir Conditioning Systems
Cooling
Daikin CAH008GDQM 3,000 CFM · Ahu ×1
Multistack ASP010YNAB 11 tons · Chiller ×1
05/14/2025Signed-offMETROPOLITAN MECHANICAL CHeating and Air Conditioning Systems
Heat / Cool
Trane M#: WSC120H3R0B2F 118,000 BTU · Condensing Unit ×1
4 jobs · most recent 12/10/2025
Water/Sanitary Gas
FiledStatusContractorScope
12/10/2025Signed-offUNIVERSAL PLUMBING INCWater/Sanitary
10/30/2025Signed-offGREGG NY PLUMBING, INCWater/Sanitary
07/11/2025Permit IssuedALMA PLBG SPRINKLER INCWater/Sanitary
08/31/2023Signed-offPARAMOUNT PIPING INCGas, Water/Sanitary
20 jobs · most recent 03/30/2026
General Wiring HVAC Wiring Boiler Controls
FiledStatusContractorScope
03/30/2026CompleteA.L. ELECTRICAL CORP.General Wiring
03/11/2026Permit IssuedKAYLEE ELECTRIC CORPGeneral Wiring
02/11/2026Permit IssuedSPECTRUM ON BROADWAY-ELEC—
01/28/2026CompleteATMOS ELECTRIC SVCE CORP—
01/09/2026CompleteDOUBLE "R" ELEC'L CONTR'GGeneral Wiring
11/15/2025CompleteJONG HYUN KIM—
09/22/2025CompleteTHE METRO GROUP ELECTRICGeneral Wiring
09/02/2025Permit IssuedD'ALCO ELECTRICAL, INC.General Wiring
07/16/2025Permit IssuedTAKING CARE OF BUS ELECTHVAC Wiring
05/14/2025Permit IssuedTAKING CARE OF BUS ELECT—
02/25/2025CompleteDAVEN ELECTRIC CORPGeneral Wiring
01/06/2025CompleteR & T ELECTRICAL CORPGeneral Wiring
04/15/2024CompleteMEGA ELEC'L CONTR'G, INC—
06/21/2023CompleteATMOS ELECTRIC SVCE CORPGeneral Wiring
06/08/2023CompleteKRAFT ELECTRIC CORPBoiler Controls
2 jobs · most recent 12/10/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
12/10/2025Signed-offADI CONTRACTING LLCTenant Protection Plan 72 Hour
10/30/2025Signed-offHUDSON CONTRACTING GROUPTenant Protection Plan 72 Hour
1 job · most recent 04/29/2024
Suspended Scaffold (SC)
FiledStatusContractorScope
04/29/2024Permit IssuedDEMARI SERVICES INCSuspended Scaffold (SC)
Building Lifecycle
All (228)Filed (38)Permit Issued (35)Signed Off (18)Facade (FISP) (6)Violation (60)Inspection (19)Objection (22)Special Inspection (30)
08/26/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/21/2026
Signed off — Alteration
Additions/modifications to medical office plumbing as per plans herewith. No change to use, egress, or occupancy.
Q01326841-I1
07/15/2026
Signed off — Alteration
INTERIOR FIT-OUT OF DENTAL OFFICE IN EXISTING COMMERCIAL SPACE. NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY
Q01212223-S1
07/15/2026
Signed off — Alteration
INTERIOR FIT-OUT OF DENTAL OFFICE IN EXISTING COMMERCIAL SPACE. NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY
Q01212223-I1
07/10/2026
Permit issued — General Construction
Q01400074-I1-GC
06/30/2026
Signed off — Alteration
Q01326649-I1
05/28/2026
Filed — Alteration
Q01400074-I1
05/27/2026
Special inspection requirement — Tenant Protection Plan Compliance
MUHAMMAD HUQ
05/11/2026
Special inspection requirement — Final
William Ryan
05/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/29/2026
Permit issued — Sign
Q01366802-I1-SG
04/28/2026
Filed — Alteration
ERECT AND INSTALL ILLUMIATED WALL SIGN TO READ "NORTHWELL HEALTH" WITH LOGO. NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE EGRESS OR OCCUPANCY
Q01366802-I1
04/22/2026
Filed — Alteration
Q01324031-I1
04/09/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/08/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/27/2026
Signed off — Alteration
ILLUMINATED ACCESSORY NON ADVERTISING BUSINESS SIGN ON WALL. SIGN WORDING: DENTAL RENAISSANCE SPA
Q01344507-I1
03/18/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/17/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/06/2026
Permit issued — Plumbing
Q01160327-S2-PL
03/05/2026
Permit issued — General Construction
Q01160327-I1-GC
03/03/2026
Special inspection requirement — Final
ARIEL GOLSHAN
02/27/2026
Signed off — Alteration
INTERIOR FIT-OUT OF DENTAL OFFICE IN EXISTING COMMERCIAL SPACE. NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY
Q01212223-S2
02/17/2026
Signed off — Alteration
Facade repairs as per plans filed herewith. No change in use occupancy or egress.
Q00994554-I1
02/12/2026
Filed — Alteration
Q01326649-P1
02/11/2026
Special inspection requirement — Tenant Protection Plan Compliance
02/10/2026
Special inspection requirement — Final
EUGENE BIFULCO
02/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
02/10/2026
Special inspection requirement — Interior lighting power
EUGENE BIFULCO
02/10/2026
Special inspection requirement — Lighting controls
EUGENE BIFULCO
02/09/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/05/2026
Special inspection requirement — Final
ADITYA DESAI
02/02/2026
Permit issued — Mechanical Systems
Q01160327-S1-MS
01/29/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/09/2026
Filed — Alteration
ILLUMINATED ACCESSORY NON ADVERTISING BUSINESS SIGN ON WALL. SIGN WORDING: DENTAL RENAISSANCE SPA
Q01344507-I1
01/09/2026
Permit issued — General Construction
Q01326649-I1-GC
01/09/2026
Permit issued — Mechanical Systems
Q01326689-I1-MS
01/09/2026
Permit issued — Sign
Q01344507-I1-SG
01/09/2026
Special inspection requirement — Final
Volodymyr Chervoniuk
12/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/22/2025
Permit issued — General Construction
Q01326649-I1-GC
12/22/2025
Permit issued — Plumbing
Q01326841-I1-PL
12/22/2025
Permit issued — Mechanical Systems
Q01326689-I1-MS
12/16/2025
Filed — Alteration
Q01326649-I1
12/10/2025
Filed — Alteration
Additions/modifications to medical office plumbing as per plans herewith. No change to use, egress, or occupancy.
Q01326841-I1
12/10/2025
Filed — Alteration
Additions/Modifications to existing mechanical system in medical office space. No change to use, egress, or occupancy.
Q01326689-I1
12/09/2025
Special inspection requirement — Ventilation and air distribution system
EUGENE BIFULCO
12/09/2025
Special inspection requirement — HVAC-R and service water heating system controls
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Maintenance information
EUGENE BIFULCO
12/09/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Tenant Protection Plan Compliance
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Energy Code Compliance Inspections
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Tenant Protection Plan Compliance
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Duct leakage testing, insulation and design
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
12/09/2025
Special inspection requirement — Maintenance information
EUGENE BIFULCO
12/03/2025
Permit issued — Mechanical Systems
Q01212223-S2-MS
12/01/2025
Special inspection requirement — Mechanical Systems
EUGENE BIFULCO
12/01/2025
Special inspection requirement — Final
EUGENE BIFULCO
11/30/2025
Filed — Alteration
INSTALLATION OF NEW BUSINESS ACCESSORY ILLUMINATED WALL SIGN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01323501-I1
Latest 60 of 228 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
11101 QUEENS4706/28/2026
LAKEWOOD GROUP203/22/2026
DEMARI SERVICES103/22/2026
FORESTER CONDOMINIUM1303/22/2026
FORESTER OWNER CORP1703/22/2026
INSIGNIA RESIDENTIAL103/22/2026
FORESTER COMPANY3103/22/2026
SULZBORGER & COLFE INC103/22/2026
FOREST OWNERS CORPORATION103/22/2026
BROOKLYN103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.503/21/2026
PAUL FUSCO CONSULTING203/21/2026
J A EXPEDITING603/21/2026
VAA403/21/2026
GREGORY RALPH ARCHITECT403/21/2026
CITY EXPEDITING203/21/2026
AE DESIGN SOLUTION803/21/2026
W J PROFESSIONAL EXPEDITING203/21/2026
WEST AZE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ADI CONTRACTING LLCGeneral Contractor604/09/2026
EMPIRE NY INSTALLATIONS INCGeneral Contractor407/08/2026
HAKKA CONTRACTING, INCGeneral Contractor407/08/2026
CRYSTAL COMFORT INCGeneral Contractor307/08/2026
RAPID RESPONSE REMDIATIONGeneral Contractor303/21/2026
ALMA DESIGN INCGeneral Contractor307/11/2026
GGP CONSTRUCTION MGTMENTGeneral Contractor203/21/2026
PARAMOUNT PIPING INCPlumbing207/08/2026
HUDSON CONTRACTING GROUPGeneral Contractor204/09/2026
D'ALCO ELECTRICAL, INC.Electrical203/22/2026
CC CONTROLLED PLBG CO.,INPlumbing207/08/2026
UNIVERSAL PLUMBING INCPlumbing106/28/2026
NATIONAL SIGN LIGHTINGScaffold106/28/2026
CUTOLO SALVATOREElectrical103/21/2026
N Y SIGN ARTScaffold107/08/2026
ROMERO ELECTRIC LLCElectrical103/22/2026
SALVATORE CUTOLOElectrical103/21/2026
DEMARI SERVICES INCGeneral Contractor104/09/2026
J&C BOINIM CORPGeneral Contractor107/08/2026
LAKEWOOD GROUP CORPGeneral Contractor107/08/2026
MEIQIJU CONSTUCTION INCGeneral Contractor107/08/2026
METROPOLITAN MECHANICAL CGeneral Contractor104/08/2026
TOWER SERVICES INCGeneral Contractor107/08/2026
ALMA PLBG SPRINKLER INCPlumbing107/08/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VERTICAL LLC8740105/28/2026
CROSSCHECK INSPECTION SER544502/12/2026
STEEL CORE ENGINEERING PL1098310/30/2025
MJ ENGINEERING & DESIGN5546307/11/2025
METROPOLITAN MECHANICAL C2277105/14/2025
NY RESTORATION TECHNOLOGY6187107/18/2024
ROBERT F. GERMAIN JR. PE5100506/29/2023
A2 ARCHITECT, PC2504306/29/2023
KATZ ENGINEERING238101/31/2022
O'ROURKE ENGINEERING, LLC5873110/22/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedALMA DESIGN INC07/10/2026
DOB NOWSignPermit IssuedNATIONAL MAINTENANCE, INC04/29/2026
DOB NOWPlumbingPermit IssuedSMART PLUMBING & HTG CORP03/06/2026
DOB NOWGeneral ConstructionPermit IssuedALMA DESIGN03/05/2026
DOB NOWMechanical SystemsPermit IssuedALMA DESIGN02/02/2026
DOB NOWGeneral ConstructionSigned-offADI CONTRACTING LLC01/09/2026
DOB NOWMechanical SystemsSigned-offADI CONTRACTING LLC01/09/2026
DOB NOWSignSigned-offSKANSKA BUILDING INC01/09/2026
DOB NOWGeneral ConstructionSigned-offADI CONTRACTING LLC12/22/2025
DOB NOWPlumbingSigned-offUNIVERSAL PLUMBING INC12/22/2025
DOB NOWMechanical SystemsSigned-offADI CONTRACTING LLC12/22/2025
DOB NOWMechanical SystemsSigned-offHUDSON CONTRACTING GROUP12/03/2025
DOB NOWMechanical SystemsPermit IssuedRAPID RESPONSE REMDIATION10/27/2025
DOB NOWPlumbingSigned-offGREGG NY PLUMBING, INC07/16/2025
DOB NOWGeneral ConstructionSigned-offHUDSON CONTRACTING GROUP07/03/2025
DOB NOWMechanical SystemsSigned-offMETROPOLITAN MECHANICAL C06/30/2025
DOB NOWSuspended ScaffoldPermit IssuedDEMARI SERVICES INC06/03/2025
DOB NOWGeneral ConstructionSigned-offLAKEWOOD GROUP05/02/2025
DOB NOWSidewalk ShedSigned-offEMPIRE NY INSTALLATIONS I04/29/2025
DOB NOWGeneral ConstructionSigned-offTOWER SERVICES INC03/27/2025
DOB NOWGeneral ConstructionSigned-offMEIQIJU CONSTUCTION INC12/13/2024
DOB NOWGeneral ConstructionSigned-offDEMARI SERVICES INC09/17/2024
DOB NOWSuspended ScaffoldPermit IssuedDEMARI SERVICES INC05/21/2024
DOB NOWSidewalk ShedSigned-offEMPIRE NY INSTALLATIONS I04/29/2024
DOB NOWPlumbingSigned-offSURPASS PLBG & HTG INC12/13/2022
DOB NOWPlumbingSigned-offSURPASS PLBG & HTG INC11/09/2022
DOB NOWGeneral ConstructionSigned-offHAKKA CONTRACTING, INC10/25/2022
DOB NOWGeneral ConstructionSigned-offHAKKA CONTRACTING, INC10/17/2022
DOB NOWPlumbingSigned-offCC CONTROLLED PLBG CO.,IN07/25/2022
DOB NOWPlumbingSigned-offCC CONTROLLED PLBG CO.,IN06/07/2022
DOB NOWBoiler EquipmentSigned-offC C CONTROLLED COMBUSTION06/07/2022
DOB NOWMechanical SystemsSigned-offCRYSTAL COMFORT01/28/2022
DOB NOWMechanical SystemsSigned-offCRYSTAL COMFORT12/03/2021
DOB NOWGeneral ConstructionSigned-offGGP CONSTRUCTION MGTMENT06/22/2021
DOB NOWConstruction FenceSigned-offJ&C BOINIM CORP07/09/2019
BIS—ISSUEDJ&C BOINIM CORP07/06/2020
BIS—ISSUEDJ&C BOINIM CORP02/12/2020
BIS—ISSUEDJ&C BOINIM CORP05/22/2019
BISPLISSUEDWNW & SONS PLBG & HTG INC05/22/2019
BISPLISSUEDWILLIAM G IAFE INC04/11/2019
+ 45 more permits on file
▾Field Inspections (DOB CAP) — 19
DateTypeResultReport
08/26/2026Fail-Final General Construction Non-Directive 14FailView ↗
05/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/08/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/18/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/17/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/09/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/29/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/31/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/09/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/16/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/09/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/24/2023Pass-Final Boiler Equipment InspectionPassView ↗
03/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 88
DateRequirementInspectorRole
05/27/2026Tenant Protection Plan ComplianceMUHAMMAD HUQspecial
05/11/2026FinalWilliam Ryanprogress
03/03/2026FinalARIEL GOLSHANprogress
02/11/2026Tenant Protection Plan Compliance—special
02/10/2026Interior lighting powerEUGENE BIFULCOenergy_progress
02/10/2026Lighting controlsEUGENE BIFULCOenergy_progress
02/10/2026Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
02/10/2026FinalEUGENE BIFULCOprogress
02/05/2026FinalADITYA DESAIprogress
01/09/2026FinalVolodymyr Chervoniukprogress
12/09/2025Ventilation and air distribution systemEUGENE BIFULCOenergy_progress
12/09/2025Maintenance informationEUGENE BIFULCOenergy_progress
12/09/2025Energy Code Compliance InspectionsEUGENE BIFULCOprogress
12/09/2025Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
12/09/2025Duct leakage testing, insulation and designEUGENE BIFULCOenergy_progress
12/09/2025Post-installed AnchorsEUGENE BIFULCOspecial
12/09/2025Tenant Protection Plan ComplianceEUGENE BIFULCOspecial
12/09/2025Tenant Protection Plan ComplianceEUGENE BIFULCOspecial
12/09/2025HVAC-R and service water piping design and insulationEUGENE BIFULCOenergy_progress
12/09/2025HVAC-R and service water heating system controlsEUGENE BIFULCOenergy_progress
12/09/2025Maintenance informationEUGENE BIFULCOenergy_progress
12/01/2025FinalEUGENE BIFULCOprogress
12/01/2025Mechanical SystemsEUGENE BIFULCOspecial
10/21/2025Maintenance informationAlexander Sheymanenergy_progress
10/21/2025Shutoff dampersAlexander Sheymanenergy_progress
Latest 25 of 88.
▾Documents — 628 on file (BIS + DOB NOW)
▸Plans & Drawings39
▸DOB NOWPlans/Sketch38
08/29/2026Q01344071-I1Request digital key ↗
08/27/2026Q00501183-I1Request digital key ↗
08/27/2026Q00591219-I1Request digital key ↗
Showing 3 of 38 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
08/28/2026Q00184915-I1Request digital key ↗
▸Applications & Permits84
▸BISPLAN / WORK APPROVAL APPLICATION45
03/14/2025421589800Open ↗
05/04/2022421269969Open ↗
03/11/2022421269969Open ↗
Showing 3 of 45 on file for this type
▸BISWORK PERMIT APPLICATION35
02/13/2020421589800Open ↗
07/17/2019421589819Open ↗
05/30/2019421589800Open ↗
Showing 3 of 35 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION2
11/18/2019421589800Open ↗
11/01/2019421589800Open ↗
▸BISIntent to Revoke Approval/Permit1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications200
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION68
01/27/2020421589819Open ↗
01/15/2020421891867Open ↗
01/15/2020421891867Open ↗
Showing 3 of 68 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature37
08/28/2026Q00184915-I1Open ↗
08/27/2026Q00501183-I1Open ↗
08/27/2026Q00591219-I1Open ↗
Showing 3 of 37 on file for this type
▸DOB NOWProgress Inspector Seal & Signature36
09/28/2026Q00724828-P1Open ↗
09/28/2026Q00724828-P1Open ↗
09/28/2026Q00724828-P1Open ↗
Showing 3 of 36 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST17
02/03/2017421401931Open ↗
02/03/2017421401815Open ↗
Showing 2 of 17 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT16
07/24/2017440421429Open ↗
02/03/2017421401815Open ↗
02/03/2017421401931Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/28/2026Q00724828-P1Open ↗
09/25/2026Q00724812-P2Open ↗
09/23/2026Q01326689-I1Open ↗
Showing 3 of 16 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
07/24/2017440421429Open ↗
Showing 1 of 3 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
07/24/2017440421429Open ↗
Showing 1 of 3 on file for this type
▸Trade Schedules & Equipment29
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE7
01/21/2020421589819Open ↗
12/20/2019421589819Open ↗
05/10/2019421589800Open ↗
Showing 3 of 7 on file for this type
▸BISSELF-CERT PLUMBING NOTICE6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT6
06/24/2021421589800Open ↗
05/20/2021421589800Open ↗
01/18/2018440421429Open ↗
Showing 3 of 6 on file for this type
▸BISEQUIPMENT USE PERMITS4
10/19/2021421589800Open ↗
01/18/2018440421429Open ↗
01/18/2018440421429Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
04/23/2018421589800Open ↗
Showing 1 of 2 on file for this type
▸BISSPRINKLER INSP REPORT : FP-851
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISSCHEDULE B - PLUMBING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
01/25/2021421589828Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection9
▸BISTenant Protection Plan and Notes7
05/17/2018421589819Open ↗
04/23/2018421589800Open ↗
01/10/2018421589800Open ↗
Showing 3 of 7 on file for this type
▸BISSTREET TREE CHECKLIST2
01/09/2018421589800Open ↗
Showing 1 of 2 on file for this type
▸Environmental & Asbestos51
▸DOB NOWDEP ACP-5: Asbestos Assessment Report21
08/27/2026Q00501183-I1Open ↗
08/26/2026Q00759287-P1Open ↗
08/26/2026Q00759287-I1Open ↗
Showing 3 of 21 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)18
01/09/2018421589800Open ↗
01/09/2018421589819Open ↗
02/03/2017421401815Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
08/27/2026Q00591219-I1Open ↗
08/26/2026Q00724828-I1Open ↗
08/24/2026Q00724812-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance42
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS18
04/02/2019421891867Open ↗
06/12/2018421589800Open ↗
04/23/2018421589800Open ↗
Showing 3 of 18 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS9
01/15/2020421891867Open ↗
01/16/2018440421429Open ↗
10/24/2017421361056Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.4
08/13/2026Q00591219-I1Open ↗
08/13/2026Q00501183-I1Open ↗
08/13/2026Q00724828-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
11/11/2021421269969Open ↗
07/24/2017440421429Open ↗
Showing 2 of 3 on file for this type
▸BISTECHNICAL REPORT: ENERGY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
07/24/2017440421429Open ↗
Showing 1 of 2 on file for this type
▸BISTR8: Energy Code Progress Inspections1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/11/2021421269969Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00724828-I1Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY4
11/11/2021421269969Open ↗
07/24/2017440421429Open ↗
Showing 2 of 4 on file for this type
▸BISHYDRAULIC FLOW CALCULATIONS1
04/24/2018421589819Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
11/08/2021421269969Open ↗
▸BISHYDRO FLOW TEST LETTER1
04/24/2018421589819Open ↗
▸Approvals, Objections & Sign-offs52
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST31
05/05/2022421269969Open ↗
02/01/2021421589828Open ↗
03/16/2020421589819Open ↗
Showing 3 of 31 on file for this type
▸BISADMINISTRATIVE OBJECTIONS12
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 12 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
04/23/2018421589800Open ↗
10/24/2017421361056Open ↗
Showing 2 of 4 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/13/2026Q01036119-I1Open ↗
08/13/2026Q01036119-P2Open ↗
08/13/2026Q01036119-P1Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
01/09/2018421589800Open ↗
▸BISFINAL1
11/08/2021421269969Open ↗
▸Cost, Insurance & Ownership53
▸BISCOST AFFIDAVIT50
02/01/2021421589828Open ↗
03/16/2020421589819Open ↗
02/27/2020421589819Open ↗
Showing 3 of 50 on file for this type
▸BISSTEEL AFFIDAVIT- FINAL2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
11/09/2021421269969Open ↗
▸Filing & Intake Forms55
▸BISEFILING COVER SHEET26
04/11/2018421589800Open ↗
01/09/2018421589828Open ↗
01/09/2018421589800Open ↗
Showing 3 of 26 on file for this type
▸BISBOROUGH INTAKE FORM16
01/21/2020421891867Open ↗
06/12/2018421401968Open ↗
01/18/2018440421429Open ↗
Showing 3 of 16 on file for this type
▸BISADDITIONAL INFORMATION10
01/27/2020421589819Open ↗
11/18/2019421589800Open ↗
07/18/2019421589819Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
07/24/2017440421429Open ↗
Showing 1 of 3 on file for this type
▸Other Documents7
▸BISGAS WELDER ANNUAL CERT : GAS-WELD3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISPLOT DIAGRAM1
01/09/2018421589800Open ↗
▸DOB NOWDHCR Document1
08/17/2026Q01324031-I1Open ↗
▸DOB NOWCalculations1
08/13/2026Q01042965-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026Q01042965-I1Open ↗