← Back
One family attached or semi-detached
111-87 41 AVENUE
QUEENS · BIN 4049908
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4Zoning
1,024 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
One family attached or semi-detached · 2,100 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 8 docs
Floor 1
Cellar3p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/31/2025$725K—Private party → Private party$708/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI406/09/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor104/09/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394206/09/2026
Building Lifecycle
All (20)Filed (4)Permit Issued (2)Signed Off (2)Violation (5)Inspection (4)Special Inspection (3)
07/10/2026
Signed off — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK: REMOVE ILLEGAL KITCHEN SINK AND 3-PC BATHROOM IN CELLAR; INSTALL NEW 3-PC BATHROOM IN CELLAR; REPLACE BATHROOM FIXTURES IN 2ND FLOOR. NO
Q01316840-I1
06/15/2026
Signed off — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH GENERAL CONSTRUCTION: REMOVE ILLEGAL PARTITIONS WALL&DOORS AND RESTORE BACK TO LEGAL CONDITION AT CELLAR;REPAINTING WALL, CEILING AND RESURFACE FLOOR AT
Q01316841-I1
06/12/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
06/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
06/09/2026
Filed — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH GENERAL CONSTRUCTION: REMOVE ILLEGAL PARTITIONS WALL&DOORS AND RESTORE BACK TO LEGAL CONDITION AT CELLAR;REPAINTING WALL, CEILING AND RESURFACE FLOOR AT
Q01316841-P1
06/09/2026
Filed — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK: REMOVE ILLEGAL KITCHEN SINK AND 3-PC BATHROOM IN CELLAR; INSTALL NEW 3-PC BATHROOM IN CELLAR; REPLACE BATHROOM FIXTURES IN 2ND FLOOR. NO
Q01316840-P1
06/09/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/12/2026
Violation issued (ECB, closed)
Unknown
12/10/2025
Permit issued — General Construction
Q01316841-I1-GC
12/05/2025
Permit issued — Plumbing
Q01316840-I1-PL
11/26/2025
Filed — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH PLUMBING WORK: REMOVE ILLEGAL KITCHEN SINK AND 3-PC BATHROOM IN CELLAR; INSTALL NEW 3-PC BATHROOM IN CELLAR; REPLACE BATHROOM FIXTURES IN 2ND FLOOR. NO
Q01316840-I1
11/26/2025
Filed — Alteration
RESOLVE ECB VIOLATIONS: 34541998X AND 34437547R; RENOVATION OF EXISTING CELLAR, 1ST AND 2ND FLOOR WITH GENERAL CONSTRUCTION: REMOVE ILLEGAL PARTITIONS WALL&DOORS AND RESTORE BACK TO LEGAL CONDITION AT CELLAR;REPAINTING WALL, CEILING AND RESURFACE FLOOR AT
Q01316841-I1
10/18/2006
Violation issued (ECB, closed)
Quality of Life
10/18/2006
Violation issued (ECB, closed)
Quality of Life
05/20/2004
Violation issued (ECB, closed)
Quality of Life
05/20/2004
Violation issued (ECB, open)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKALE CONSTRUCTION INC12/10/2025
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG12/05/2025
1 project · most recent 06/09/2026
Water/Sanitary
FiledStatusContractorScope
06/09/2026Signed-offJOHN FITZGERALD PLBG &HTGWater/Sanitary
1 project · most recent 03/30/2026
General Wiring
FiledStatusContractorScope
03/30/2026CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/12/2026Pass-Final General Construction Non-Directive 14PassView ↗
06/09/2026Fail-Final General Construction Non-Directive 14FailView ↗
03/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/05/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/10/2026Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
06/10/2026Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
06/10/2026Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026Q01316840-P1Request digital key ↗
08/18/2026Q01316840-I1Request digital key ↗
08/16/2026Q01316841-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/18/2026Q01316840-P1Open ↗
08/16/2026Q01316841-P1Open ↗
08/13/2026Q01316841-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026Q01316840-P1Open ↗
08/18/2026Q01316840-I1Open ↗
08/16/2026Q01316841-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026Q01316841-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q01316841-I1Open ↗