← Back
Two family frame
1117 EAST 105 STREET
BROOKLYN · BIN 3232335
💬 Discuss this project
1965Year Built
2Stories
B2Building Class
R4Zoning
2,947 sfGross Floor Area
2Units
Two family frame · 2,675 sf lot · 1.1 FAR built · Flood zone X500
Locations of Work
Architecture
Roof1p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CROWN BUILDER CONSTRUCT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC108/30/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VOLTAIC SOLAIRE LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854108/30/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
01/22/2026
Signed off — Alteration
Installation of PV system on existing roof no change to egress or use of occupancy
B01276655-I1
09/04/2025
Permit issued — Solar
B01276655-I1-SL
08/30/2025
Filed — Alteration
Installation of PV system on existing roof no change to egress or use of occupancy
B01276655-I1
08/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
08/24/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
08/24/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
08/24/2025
Special inspection requirement — Final
TOM PETERSEN
08/24/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offVOLTAIC SOLAIRE LLC09/04/2025
BISOTISSUEDCROWN BUILDER & CONSTRUCT06/06/2012
2 projects · most recent 10/17/2025
FiledStatusContractorScope
10/17/2025CompleteBERGER QUALITY ELEC'L CON3 meters
08/03/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/24/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
08/24/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
08/24/2025Energy Code Compliance InspectionsTOM PETERSENprogress
08/24/2025FinalTOM PETERSENprogress
08/24/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026B01276655-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
08/22/2012320482606Open ↗
06/11/2012320482606Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
05/24/2012320482606Open ↗
▸Seals & Professional Certifications10
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
10/30/2017320482606Open ↗
10/30/2017320482606Open ↗
05/24/2012320482606Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026B01276655-I1Open ↗
08/25/2026B01276655-I1Open ↗
08/25/2026B01276655-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B01276655-I1Open ↗
08/25/2026B01276655-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
05/24/2012320482606Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01276655-I1Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/24/2012320482606Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01276655-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
10/30/2017320482606Open ↗
10/30/2017320482606Open ↗
05/24/2012320482606Open ↗
▸Approvals, Objections & Sign-offs4
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
10/30/2017320482606Open ↗
06/30/2017320482606Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/24/2012320482606Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01276655-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/30/2017320482606Open ↗
05/24/2012320482606Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
05/24/2012320482606Open ↗
▸BISBOROUGH INTAKE FORM1
10/30/2017320482606Open ↗