← Back
Elevator apt, fireproof with stores
First Houses (NYCHA)
112 EAST 3 STREET · East Village · BIN 1077953
💬 Discuss this project
1920Year Built
4Stories
D6Building Class
R8BZoning
101,908 sfGross Floor Area
262Units
LL97 Covered0 Open ViolationsFDNY Report ↗
Elevator apt, fireproof with stores · Owner of record: NYC HOUSING AUTHORITY · 53,562 sf lot · 1.9 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneralOther
Permit Issued — active, not yet Signed-off
Roof25p · 3 filings · 20 docs
Floor 44p · 2 filings · 20 docs
Floor 32p · 1 filing · 19 docs
Floor 22p · 1 filing · 19 docs
Floor 1Under Construction7p · 2 filings · 20 docs
Site & exteriorUnder Construction34p · 4 filings · 17 docs
Filed — no permit issued5p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYCHA1307/08/2026
NEW YORK CITY HOUSING AUTHORITY907/08/2026
VINBAYTEL DEVELOPMENTS507/08/2026
NYCHA CAPITAL PROJECTS PM TEAM1203/21/2026
NYC Housing Authority103/21/2026
ZHN CONTRACTING103/21/2026
NYC HOUSING103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VERSATILE ENGINEERING, P.C.205/14/2025
JOEL PHAGOO P.E. PLLC507/30/2024
SUPERSTRUCTURES ENG. + ARCH.308/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERSTRUCTURES ENG + ARCH303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RAVEN CONSTRUCTION SERVICGeneral Contractor1207/08/2026
JAMES MAGRIPLESElectrical503/21/2026
SKYLINE P & H INCPlumbing203/22/2026
JEMCO ELECT. CONTRS INCElectrical203/22/2026
EFFICIENT CLIMATE SOLUTIOGeneral Contractor107/08/2026
JEMCO ELECTRICAL CONT INCGeneral Contractor107/08/2026
ADAM'S EUROPEAN CONTRACTINGGeneral Contractor107/08/2026
RIQUE CONSRUCTION INCElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CENTURY TESTING & CONSULT4081105/14/2025
JOEL PHAGOO ,PE, PLLC2416207/30/2024
MT GROUP798208/22/2023
Building Lifecycle
All (58)Filed (10)Permit Issued (9)Signed Off (5)Violation (4)Inspection (4)Objection (7)Special Inspection (19)
07/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/05/2026
Permit issued — Mechanical Systems
M01225712-I1-MS
05/27/2025
Objection raised — Other
05/27/2025
Objection resolved — Addressed
05/14/2025
Filed — Alteration
Install 3 new condensing units (attached to the rear facade wall) and 3 air handlers inside existing commercial space (Pharmacy)
M01225712-I1
05/14/2025
Special inspection requirement — Mechanical Systems
FRANZ SEBORGA
05/14/2025
Special inspection requirement — Final
FRANZ SEBORGA
03/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/24/2025
Signed off — Alteration
M00921185-I1
02/11/2025
Signed off — Alteration
NYCHA 1st Houses Bldg 03, Exterior & Roof repairs per plans filed, including: Removal /replacement/ repairs to roofing system, bulkhead door, masonry, lintels, parapet & roof drains. Install new guard rails.
M00840347-I1
01/21/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946578-I1
01/21/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946582-I1
01/21/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946583-I1
10/03/2024
Permit issued — Construction Fence
M00946582-I1-FN
10/03/2024
Permit issued — Sidewalk Shed
M00946578-I1-SH
10/03/2024
Permit issued — Supported Scaffold
M00946583-I1-SF
07/30/2024
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946583-P1
07/30/2024
Special inspection requirement — Post-installed Anchors
JOEL PHAGOO
06/27/2024
Permit issued — Structural
M00840347-I1-GC-CX
06/17/2024
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946578-P1
06/05/2024
Permit issued — General Construction
M00921185-I1-GC
02/28/2024
Objection raised — Accessibility
02/28/2024
Objection resolved — Resolved
02/15/2024
Objection raised — Inspections
02/15/2024
Objection raised — Admin
02/15/2024
Objection raised — Scope
10/17/2023
Permit issued — Construction Fence
M00946582-I1-FN
10/17/2023
Permit issued — Sidewalk Shed
M00946578-I1-SH
10/12/2023
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946578-I1
10/12/2023
Filed — Alteration
INSTALLATION OF TEMPORARY CHAIN LINK FENCE AS PER PLANS. CHAIN LINK FENCE SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946582-I1
10/12/2023
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00946583-I1
10/12/2023
Permit issued — Supported Scaffold
M00946583-I1-SF
09/07/2023
Filed — Alteration
Install 3 new condending units and 3 air handlers inside commercial space (Pharmacy)
M00927332-I1
08/30/2023
Special inspection requirement — Final
08/30/2023
Special inspection requirement — Mechanical Systems
08/23/2023
Special inspection requirement — Post-installed Anchors
Marisa Harte
08/23/2023
Special inspection requirement — Structural Wood Frame
Marisa Harte
08/23/2023
Special inspection requirement — Final
Paul Millman
08/23/2023
Special inspection requirement — Insulation placement and R values
Marisa Harte
08/23/2023
Special inspection requirement — Tenant Protection Plan Compliance
Marisa Harte
08/23/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Marisa Harte
08/23/2023
Special inspection requirement — Masonry
Marisa Harte
08/22/2023
Filed — Alteration
NYCHA 1st Houses Bldg 03, Exterior & Roof repairs per plans filed, including: Removal /replacement/ repairs to roofing system, bulkhead door, masonry, lintels, parapet & roof drains. Install new guard rails.
M00840347-P1
08/21/2023
Filed — Alteration
M00921185-I1
08/18/2023
Special inspection requirement — Tenant Protection Plan Compliance
08/18/2023
Special inspection requirement — Final
Paul Millman
08/18/2023
Special inspection requirement — Structural Wood Frame
Marisa Harte
08/18/2023
Special inspection requirement — Insulation placement and R values
Marisa Harte
08/18/2023
Special inspection requirement — Masonry
Marisa Harte
08/18/2023
Special inspection requirement — Post-installed Anchors
Marisa Harte
08/18/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Marisa Harte
05/02/2023
Filed — Alteration
NYCHA 1st Houses Bldg 03, Exterior & Roof repairs per plans filed, including: Removal /replacement/ repairs to roofing system, bulkhead door, masonry, lintels, parapet & roof drains. Install new guard rails.
M00840347-I1
03/06/2019
Violation issued (FDNY_NOV, closed)
04/30/2018
Violation issued (FDNY_NOV, closed)
01/03/2018
Violation issued (ECB, closed)
Construction
08/19/2002
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedEFFICIENT CLIMATE SOLUTIO05/05/2026
DOB NOWConstruction FenceSigned-offRAVEN CONSTRUCTION SERVIC10/03/2024
DOB NOWSidewalk ShedSigned-offRAVEN CONSTRUCTION SERVIC10/03/2024
DOB NOWSupported ScaffoldSigned-offRAVEN CONSTRUCTION SERVIC10/03/2024
DOB NOWStructuralSigned-offADAM'S EUROPEAN CONTRACTING06/27/2024
DOB NOWGeneral ConstructionSigned-offJEMCO ELECTRICAL CONT06/05/2024
DOB NOWConstruction FenceSigned-offRAVEN CONSTRUCTION SERVIC10/17/2023
DOB NOWSidewalk ShedSigned-offRAVEN CONSTRUCTION SERVIC10/17/2023
DOB NOWSupported ScaffoldSigned-offRAVEN CONSTRUCTION SERVIC10/12/2023
BISOTISSUEDDFC CONSTRUCTION INC10/18/2010
BISPLISSUEDDELPHI PLBG. & HTG., INC06/30/2006
BISPLISSUEDV. C. VITANZA SONS INC10/06/2003
BISOTISSUEDV.C. VITANZA SONS INC05/01/2003
BISEQISSUEDZHN CONTRACTING CORP11/18/2002
BISOTISSUEDV.C. VITANZA SONS INC03/26/2002
BISOTISSUEDV.C. VITANZA SONS INC08/23/2001
BISOTISSUEDV.C. VITANZA SONS INC10/18/2000
BISPLISSUEDV. C. VITANZA SONS INC09/22/1999
BISOTISSUEDV.C. VITANZA SONS INC09/22/1999
BISPLISSUEDV. C. VITANZA SONS INC07/09/1998
2 projects · most recent 05/14/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/14/2025Permit IssuedEFFICIENT CLIMATE SOLUTIOAir Conditioning Systems
Cooling
Mitsubishi Electric MUZ-GS36NA2 36,000 BTU · Condensing Unit ×2
MUZ-GL18NA 18,000 BTU · Condensing Unit ×1
09/07/2023——Air Conditioning Systems
Cooling
Mitsubishi Electric OUTDOOR UNIT MUZ-GS36NA 18,000 BTU · Condensing Unit ×3
7 projects · most recent 02/03/2025
General Wiring Lighting
FiledStatusContractorScope
02/03/2025CompleteJEMCO ELECT. CONTRS INCGeneral Wiring
02/03/2025CompleteJEMCO ELECT. CONTRS INCGeneral Wiring
02/03/2025CompleteJEMCO ELECT. CONTRS INCGeneral Wiring
02/03/2025CompleteJEMCO ELECT. CONTRS INCGeneral Wiring
05/21/2024CompleteTRI-STATE ELECL & MECHL IGeneral Wiring
10/11/2023CompleteARCADIA ELECT'L CO. INC.—
08/17/2018CompleteMAC FHIONNGHAILE & SONSGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
05/14/2025Mechanical SystemsFRANZ SEBORGAspecial
05/14/2025FinalFRANZ SEBORGAprogress
07/30/2024Post-installed AnchorsJOEL PHAGOOspecial
08/30/2023Final—progress
08/30/2023Mechanical Systems—special
08/23/2023Post-installed AnchorsMarisa Hartespecial
08/23/2023Structural Wood FrameMarisa Harteprogress
08/23/2023FinalPaul Millmanprogress
08/23/2023Insulation placement and R valuesMarisa Harteenergy_progress
08/23/2023Tenant Protection Plan ComplianceMarisa Hartespecial
08/23/2023Structural Stability – Alterations of existing buildingsMarisa Hartespecial
08/23/2023MasonryMarisa Hartespecial
08/18/2023Tenant Protection Plan Compliance—special
08/18/2023FinalPaul Millmanprogress
08/18/2023Structural Wood FrameMarisa Harteprogress
08/18/2023Insulation placement and R valuesMarisa Harteenergy_progress
08/18/2023MasonryMarisa Hartespecial
08/18/2023Post-installed AnchorsMarisa Hartespecial
08/18/2023Structural Stability – Alterations of existing buildingsMarisa Hartespecial
▾Documents — 80 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/29/2026M00921185-I1Request digital key ↗
08/29/2026M00840347-P1Request digital key ↗
08/29/2026M00840347-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits8
▸DOB NOWLPC Approval/Permit5
08/13/2026M01225712-I1Open ↗
08/13/2026M00840347-P1Open ↗
08/13/2026M00921185-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
04/29/2019123805454Open ↗
10/19/2010120497621Open ↗
▸BISWORK PERMIT APPLICATION1
10/22/2010120497621Open ↗
▸Seals & Professional Certifications30
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/29/2026M00921185-I1Open ↗
08/29/2026M00840347-I1Open ↗
08/29/2026M00840347-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
08/25/2026M00840347-P1Open ↗
08/25/2026M00840347-P1Open ↗
08/25/2026M00840347-P1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
04/29/2019123805454Open ↗
04/08/2013120497621Open ↗
11/30/2011120497621Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/25/2026M00840347-P1Open ↗
08/24/2026M01225712-I1Open ↗
08/23/2026M00946583-P1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/19/2010120497621Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/19/2010120497621Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
10/19/2010120497621Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/29/2019123805454Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026M00921185-I1Open ↗
08/29/2026M00840347-P1Open ↗
08/29/2026M00840347-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/19/2010120497621Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/07/2020123805454Open ↗
▸Approvals, Objections & Sign-offs14
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/29/2026M00921185-I1Open ↗
08/13/2026M00946578-P1Open ↗
08/13/2026M00946582-I1Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
04/08/2013120497621Open ↗
12/21/2011120497621Open ↗
11/30/2011120497621Open ↗
Showing 3 of 4 on file for this type
▸BISLANDMARKS APPROVAL2
01/07/2020123805454Open ↗
04/08/2013120497621Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/26/2010120497621Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026M01225712-I1Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
04/29/2019123805454Open ↗
04/08/2013120497621Open ↗
04/08/2013120497621Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
04/29/2019123805454Open ↗
10/19/2010120497621Open ↗
▸BISADDITIONAL INFORMATION1
01/07/2020123805454Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
04/29/2019123805454Open ↗
▸DOB NOWProof of Historic Building1
08/13/2026M00927332-I1Open ↗