| Owner | Filings | Most Recent |
|---|---|---|
| 40TH DEVELOPMENT | 15 | 03/21/2026 |
| HOUSING PRESERVATION DEVELOPMENT | 11 | 07/08/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/22/2019 | $3.0M | — | — → — | $656/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| H & O ENGINEERING, DPC | 2 | 11/14/2024 |
| JOEL PHAGOO P.E. PLLC | 1 | 10/15/2024 |
| DOMINICK R. PILLA ASSOCIATES, PC | 1 | 07/16/2020 |
| JOSELOW AND ASSOCIATES | 2 | 06/08/2020 |
| KZ ENGINEERING, P.C | 3 | 06/20/2019 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPEDITE DEM | 4 | 03/21/2026 |
| DOMINICK R PILLA ASSOCIATES | 4 | 03/21/2026 |
| SYNERGY BUILDING CONSULTANTS | 3 | 03/21/2026 |
| A1 EXPEDITING SERVICE | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ARSENAL SCAFFOLD INC | General Contractor | 27 | 07/08/2026 |
| STATE CONTRACTING CORP NY | General Contractor | 4 | 07/08/2026 |
| ALEXANDER EUGENE | Electrical | 1 | 03/21/2026 |
| NASH ELECTRIC SERVICES IN | Electrical | 1 | 03/22/2026 |
| AKM CONSTRUCTION NY CORP | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| H & O ENGINEERING, DPC | 5595 | 1 | 11/14/2024 |
| DOMINICK R. PILLA | 1300 | 3 | 07/16/2020 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Full Demolition | Signed-off | STATE CONTRACTING CORP NY | 01/17/2025 |
| DOB NOW | Construction Fence | Signed-off | STATE CONTRACTING CORP NY | 11/15/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | AKM CONSTRUCTION NY | 10/16/2024 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 03/05/2024 |
| DOB NOW | Construction Fence | Signed-off | ARSENAL SCAFFOLD INC | 03/15/2023 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 03/14/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | ARSENAL SCAFFOLD INC | 03/14/2023 |
| DOB NOW | Construction Fence | Signed-off | ARSENAL SCAFFOLD INC | 03/22/2022 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 03/22/2022 |
| DOB NOW | Sidewalk Shed | Signed-off | ARSENAL SCAFFOLD INC | 03/22/2022 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 03/19/2021 |
| DOB NOW | Sidewalk Shed | Signed-off | ARSENAL SCAFFOLD INC | 03/18/2021 |
| DOB NOW | Construction Fence | Signed-off | ARSENAL SCAFFOLD INC | 03/18/2021 |
| DOB NOW | Sidewalk Shed | Signed-off | ARSENAL SCAFFOLD INC | 03/27/2020 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 03/23/2020 |
| DOB NOW | Construction Fence | Signed-off | ARSENAL SCAFFOLD INC | 03/23/2020 |
| DOB NOW | Supported Scaffold | Signed-off | ARSENAL SCAFFOLD INC | 06/20/2019 |
| DOB NOW | Construction Fence | Signed-off | ARSENAL SCAFFOLD INC | 06/06/2019 |
| DOB NOW | Sidewalk Shed | Signed-off | ARSENAL SCAFFOLD INC | 06/05/2019 |
| BIS | — | ISSUED | PRIDE BUILDERS LLC | 07/21/2021 |
| BIS | — | ISSUED | PRIDE BUILDERS LLC | 03/04/2020 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/08/2020 | — | — | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Daikin RXYQ168XATJA, RXYQ192XATJA 369,687 BTU · Vrf Outdoor ×2 RXYQ72XATJA, RXYQ168XATJA 236,219 BTU · Vrf Outdoor ×2 Heating Daikin RXYQ168XATJA, RXYQ192XATJA 235,903 BTU · Vrf Outdoor ×2 RXYQ72XATJA, RXYQ168XATJA 156,985 BTU · Vrf Outdoor ×2 Ventilation Greenheck CSP-A200 65 CFM · Exhaust Fan ×16 CSP-A200-VG 75 CFM · Exhaust Fan ×1 CSP-A700-VG 150 CFM · Exhaust Fan ×1 CUE-099-VG 150 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/08/2020 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/19/2024 | Complete | HIGH QUALITY ELECTRIC OF | — |
| 05/28/2019 | Complete | NASH ELECTRIC SERVICES IN | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/16/2020 | — | — | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/14/2024 | Signed-off | STATE CONTRACTING CORP NY | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/19/2024 | Structural Stability – Alterations of existing Buildings | SANTIAGO HELMAN | special |
| 08/19/2024 | Demolition | SANTIAGO HELMAN | special |
| 06/15/2020 | Smoke Control Systems Testing | DOMINICK PILLA | special |
| 06/04/2020 | Shutoff dampers | DOMINICK PILLA | energy_progress |
| 06/04/2020 | Heating Systems | DOMINICK PILLA | special |
| 06/04/2020 | HVAC and service water heating equipment | DOMINICK PILLA | energy_progress |
| 06/04/2020 | Duct leakage testing | DOMINICK PILLA | energy_progress |
| 06/04/2020 | Energy Code Compliance Inspections | — | progress |
| 06/04/2020 | HVAC and service water heating system controls | DOMINICK PILLA | energy_progress |
| 06/04/2020 | Electrical energy consumption | DOMINICK PILLA | energy_progress |
| 06/04/2020 | Maintenance information | DOMINICK PILLA | energy_progress |
| 06/04/2020 | HVAC insulation and sealing | DOMINICK PILLA | energy_progress |
| 01/07/2020 | Final | — | progress |
| 01/07/2020 | Mechanical Systems | DOMINICK PILLA | special |