← Back
Home for indigent children, aged, homeless
112 WEST 124 STREET
MANHATTAN · BIN 1057793
💬 Discuss this project
1910Year Built
5Stories
N2Building Class
C4-4Zoning
7,380 sfGross Floor Area
1Units
11 Open Violations ▸
Home for indigent children, aged, homeless · 2,069 sf lot · 3.57 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VINCENT J. LIOTTA P.E.102/04/2025
FL&M ENGINEERING DESIGN &INSPECTION107/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AE DESIGN SOLUTION203/21/2026
THE GREEN STUDIO103/21/2026
MILLENNIUM DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MC SUPERSTRUCTURE INCGeneral Contractor203/21/2026
AFGO MECHANICAL SVCS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VINCENT J. LIOTTA P. E.1974102/04/2025
PHILIBERT ENGINEERING, PC223108/22/2024
Building Lifecycle
All (34)Filed (3)Permit Issued (4)Signed Off (3)Violation (17)Special Inspection (7)
05/08/2026
Violation issued (HPD, open)
A
01/28/2026
Signed off — Alteration
M01086944-I1
01/27/2026
Permit issued — Suspended Scaffold
M01086944-I1-SC
11/17/2025
Violation issued (HPD, open)
I
06/16/2025
Violation issued (HPD, open)
A
06/06/2025
Signed off — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01083769-I1
05/01/2025
Signed off — Alteration
INSTALLATION OF 4 HEATPUMP UNITS ON SETBACK ROOF WITH A TOTAL CAPACITY OF 20 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01158824-I1
02/20/2025
Permit issued — Mechanical Systems
M01158824-I1-MS
02/04/2025
Filed — Alteration
INSTALLATION OF 4 HEATPUMP UNITS ON SETBACK ROOF WITH A TOTAL CAPACITY OF 20 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
M01158824-I1
02/03/2025
Special inspection requirement — Tenant Protection Plan Compliance
Vincent Liotta
12/20/2024
Special inspection requirement — Final
Vincent Liotta
12/20/2024
Special inspection requirement — Mechanical Systems
Vincent Liotta
12/20/2024
Special inspection requirement — Maintenance information
Vincent Liotta
12/20/2024
Special inspection requirement — HVAC-R and service water heating system controls
Vincent Liotta
12/20/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Vincent Liotta
12/20/2024
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Liotta
11/22/2024
Violation issued (HPD, open)
I
08/28/2024
Permit issued — Suspended Scaffold
M01086944-I1-SC
08/22/2024
Filed — Alteration
M01086944-I1
07/31/2024
Permit issued — Sidewalk Shed
M01083769-I1-SH
07/30/2024
Filed — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M01083769-I1
04/17/2024
Violation issued (HPD, open)
A
11/15/2023
Violation issued (HPD, open)
I
03/31/2023
Violation issued (HPD, open)
A
11/02/2022
Violation issued (HPD, open)
I
03/10/2022
Violation issued (HPD, open)
I
03/10/2022
Violation issued (HPD, open)
A
04/20/2021
Violation issued (HPD, open)
A
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldSigned-offPENTA RESTORATION CORP01/27/2026
DOB NOWMechanical SystemsSigned-offAFGO MECHANICAL SVCS02/20/2025
DOB NOWSuspended ScaffoldSigned-offPENTA RESTORATION CORP08/28/2024
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC07/31/2024
1 project · most recent 07/22/2024
FiledStatusContractorScope
07/22/2024CompleteNASH ELECTRIC SERVICES IN—
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
02/03/2025Tenant Protection Plan ComplianceVincent Liottaspecial
12/20/2024FinalVincent Liottaprogress
12/20/2024Mechanical SystemsVincent Liottaspecial
12/20/2024Maintenance informationVincent Liottaenergy_progress
12/20/2024HVAC-R and service water heating system controlsVincent Liottaenergy_progress
12/20/2024HVAC-R and service water piping design and insulationVincent Liottaenergy_progress
12/20/2024HVAC-R and service water heating equipmentVincent Liottaenergy_progress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026M01083769-I1Request digital key ↗
08/26/2026M01086944-I1Request digital key ↗
08/25/2026M01158824-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M01158824-I1Open ↗
08/13/2026M01083769-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/19/2026M01158824-I1Open ↗
09/19/2026M01158824-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/19/2026M01158824-I1Open ↗
09/19/2026M01158824-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist2
08/13/2026M01158824-I1Open ↗
08/13/2026M01083769-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026M01158824-I1Open ↗
▸Other Documents2
▸DOB NOWCalculations1
08/13/2026M01086944-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M01086944-I1Open ↗