RoofReplace rooftop condensing units2p · 1 filing · 10 docs
Floor 1Home Depot4p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Home Depot USA1003/21/2026
HD Development of Maryland103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Robert Pia108/04/2023
Martin A. Passante Architect302/23/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B & G Electrical Contracting of NY IElectrical103/22/2026
Dooley Electric CoElectrical103/21/2026
Adco ElectricalElectrical103/21/2026
Emcor Services NY/NJGeneral Contractor107/08/2026
Tomm Electricspecialty_contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Triangle Inspection & Tes7495302/23/2022
Building Lifecycle
All (30)Filed (4)Permit Issued (2)Violation (19)Inspection (1)Special Inspection (4)
05/02/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/17/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/07/2023
Violation issued (FDNY_NOV, closed)
11/05/2023
Violation issued (FDNY_NOV, closed)
11/01/2023
Violation issued (FDNY_NOV, closed)
08/25/2023
Permit issued — General Construction
Q00913147-I1-GC
08/04/2023
Filed — Alteration
Q00913147-I1
02/24/2022
Special inspection requirement — Mechanical Systems
Rajasekhar Sakhamuri
02/24/2022
Special inspection requirement — Final
Martin Passante
02/23/2022
Filed — Alteration
replace 19 like for like roof top condensing units
Q00568750-P2
02/11/2022
Filed — Alteration
replace 19 like for like roof top condensing units
Q00568750-P1
02/11/2022
Special inspection requirement — Mechanical Systems
Rajasekhar Sakhamuri
02/11/2022
Special inspection requirement — Final
Martin Passante
10/15/2021
Permit issued — Mechanical Systems
Q00568750-I1-MS
10/13/2021
Filed — Alteration
replace 19 like for like roof top condensing units
Q00568750-I1
04/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/03/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/01/2016
Violation issued (ECB, closed)
Unknown
02/01/2016
Violation issued (ECB, closed)
Construction
08/31/2011
Violation issued (FDNY_NOV, closed)
11/30/2009
Violation issued (FDNY_NOV, closed)
11/19/2009
Violation issued (FDNY_NOV, closed)
08/26/2005
Violation issued (FDNY_NOV, closed)
08/29/2000
Violation issued (FDNY_NOV, closed)
08/29/2000
Violation issued (FDNY_NOV, closed)
01/26/2000
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedTomm Electric08/25/2023
DOB NOWMechanical SystemsSigned-offEmcor Services NY/NJ10/15/2021
BISPLISSUEDUniversal Plumbing05/14/2019
BISOTISSUEDRetail Constru & Signage08/04/2017
BISPLISSUEDStellmar Plumbing & Mechanical11/14/2016
BISOTISSUEDRubicon Professional Services09/12/2016
BISFSISSUEDJack Piccini02/01/2016
1 project · most recent 02/23/2022
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/23/2022Signed-offEmcor Services NY/NJAir Conditioning Systems
Cooling
Lennox LGM240U4MH1G 20 tons · Condensing Unit ×13
LGM36U4EQ1G 3 tons · Condensing Unit ×2
LGM048U4EX1G 4 tons · Condensing Unit ×1
LGM060U4EX1G 5 tons · Condensing Unit ×1
LGM092U4EH1G 7 tons · Condensing Unit ×1
LGM180U4MM1G 15 tons · Condensing Unit ×1
YCD241C4HACA 20 tons · Condensing Unit ×13
YHC036A4RHA22D0 3 tons · Condensing Unit ×2
48TCEA04A2A6A 4 tons · Condensing Unit ×1
YCD181C4HACA 15 tons · Condensing Unit ×1
YHC060A4RLA24D0 5 tons · Condensing Unit ×1
YHC092A4RHA 7 tons · Condensing Unit ×1
3 projects · most recent 10/16/2023
General Wiring
FiledStatusContractorScope
10/16/2023CompletePowerone Elect'l Contracting—
10/21/2021Permit IssuedElectrical SolutionsGeneral Wiring
06/05/2018CompleteB & G Electrical Contracting of NY IGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/17/2023Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
02/24/2022Mechanical SystemsRajasekhar Sakhamurispecial
02/24/2022FinalMartin Passanteprogress
02/11/2022Mechanical SystemsRajasekhar Sakhamurispecial
02/11/2022FinalMartin Passanteprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Home DepotRetailFloor 1
Project Q00913147 Alteration · Permit Entire · 08/04/2023
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 73 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026Q00568750-P2Request digital key ↗
08/26/2026Q00568750-I1Request digital key ↗
08/26/2026Q00568750-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION10
04/03/2019421949360Open ↗
07/25/2017421488376Open ↗
01/13/2017421349302Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION6
05/22/2019421949360Open ↗
08/08/2017421488376Open ↗
11/21/2016421349302Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications22
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
05/22/2019421949360Open ↗
04/16/2019421949360Open ↗
04/03/2019421949360Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026Q00568750-I1Open ↗
08/26/2026Q00568750-P1Open ↗
08/24/2026Q00913147-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
07/25/2017421488376Open ↗
01/26/2016421258891Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
07/25/2017421488376Open ↗
01/26/2016421258891Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q00568750-I1Open ↗
08/22/2026Q00568750-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00568750-I1Open ↗
08/22/2026Q00568750-P1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/03/2019421949360Open ↗
07/21/2016421349302Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
01/26/2016421258891Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
05/21/2019421949360Open ↗
07/25/2017421488376Open ↗
07/21/2016421349302Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
11/16/2017421488376Open ↗
06/23/2016421258891Open ↗
06/23/2016421258891Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
07/25/2017421488376Open ↗
01/26/2016421258891Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
09/19/2016421349302Open ↗
05/02/2016421258891Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
04/03/2019421949360Open ↗
11/16/2017421488376Open ↗
07/25/2017421488376Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms11
▸BISADDITIONAL INFORMATION6
04/19/2019421949360Open ↗
01/19/2017421349302Open ↗
01/13/2017421349302Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET4
04/03/2019421949360Open ↗
07/24/2017421488376Open ↗
07/21/2016421349302Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM1
11/16/2017421488376Open ↗