| Owner | Filings | Most Recent |
|---|---|---|
| BK LINCOLN HOLDINGS | 7 | 07/08/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/08/2025 | $490K | — | — → — | $510/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ADEL SAGEER ARCHITECT, PLLC | 3 | 03/20/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ZAQ CONSTRUCTION INC | General Contractor | 1 | 04/09/2026 |
| THOMAS F. CASH & SONS INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ZHENG & ASSOCIATES LLC | 7330 | 3 | 03/20/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | ZAQ CONSTRUCTION INC | 01/30/2026 |
| DOB NOW | Plumbing | Permit Issued | THOMAS F. CASH & SONS INC | 01/28/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/14/2026 | Signed-off | ZAQ CONSTRUCTION INC | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric 9,000 9,000 BTU · Fan Coil Indoor ×5 MSZ-GX12NL 12,000 BTU · Fan Coil Indoor ×2 MUZ-GS18NA-U1 18,000 BTU · Heat Pump Outdoor ×1 MUZ-GS24NA-U1 22,400 BTU · Heat Pump Outdoor ×1 MUZ-GS30NA2-U1 30,600 BTU · Heat Pump Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/20/2026 | Permit Issued | THOMAS F. CASH & SONS INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/20/2026 | Permit Issued | P.L. ELEC'L CONTR'G CORP | 1 meters, 1 new_meters |
| 04/25/2025 | Permit Issued | P.L. ELEC'L CONTR'G CORP | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/11/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/11/2026 | Certified StandPipe - SD - Alarm Sys 64/09 - Finish | Certified | View ↗ |
| 04/13/2026 | Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments) | Certified | View ↗ |
| 03/25/2026 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/25/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/25/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/24/2026 | Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet) | Certified | View ↗ |
| 03/20/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 05/28/2025 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 05/27/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/21/2025 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 04/02/2025 | Fail-Final PL - Up to 9 Requested Floors | Fail | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/23/2026 | Fire-Resistant Penetrations and Joints | Jinfar Liu | special |
| 01/14/2026 | HVAC-R and service water piping design and insulation | Jinfar Liu | energy_progress |
| 01/14/2026 | HVAC-R and service water heating system controls | Jinfar Liu | energy_progress |
| 01/14/2026 | HVAC-R and service water heating equipment | Jinfar Liu | energy_progress |
| 01/14/2026 | Fenestration air leakage | Jinfar Liu | energy_progress |