← Back
Two family frame
1125 DECATUR STREET
BROOKLYN · Bushwick (East) · BIN 3079473
💬 Discuss this project
1925Year Built
2Stories
B2Building Class
R6Zoning
2,700 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family frame · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingOther
Floor 29p · 1 filing · 12 docs
Floor 11p · 1 filing · 12 docs
Cellar2p · 1 filing · 12 docs
Filed — no permit issued9p · 1 filing · 5 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BRENT M. PORTER, ARCHITECT, AND ASS404/24/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SECOND FLOOR STUDIOS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INNOVATIVE HEATING SOLUTIPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BRENT M. PORTER, ARCHITEC4140404/24/2026
Building Lifecycle
All (53)Filed (4)Permit Issued (1)Violation (2)Inspection (3)Objection (38)Special Inspection (5)
07/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brent Porter
04/24/2026
Filed — Alteration
MINOR PLUMBING WORK AT SECOND FLOOR, CELLAR, BASEMENT, FIRST FLOOR FOR RELOCATION OF BATHROOM, POWDER ROOM, KITCHEN, W/ ELECTRICAL HOT WATER HEATERS FOR NEW FIXTURES ON EXIST'G ROUGHINGS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY
B01136501-P2
04/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brent Porter
04/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/03/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/03/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/18/2026
Permit issued — Plumbing
B01136501-I1-PL
02/13/2026
Objection resolved — Addressed
02/10/2026
Objection resolved — Addressed
02/10/2026
Objection resolved — Addressed
02/10/2026
Objection resolved — Addressed
12/09/2025
Objection raised — Scope
12/09/2025
Objection raised — Plumbing
12/09/2025
Objection raised — Scope
12/09/2025
Objection raised — Plumbing
09/29/2025
Filed — Alteration
MINOR PLUMBING WORK AT SECOND FLOOR, CELLAR, BASEMENT, FIRST FLOOR FOR RELOCATION OF BATHROOM, POWDER ROOM, KITCHEN, W/ ELECTRICAL HOT WATER HEATERS FOR NEW FIXTURES ON EXIST'G ROUGHINGS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY
B01136501-P1
11/08/2024
Filed — Alteration
MINOR PLUMBING WORK AT SECOND FLOOR, CELLAR, BASEMENT, FIRST FLOOR FOR RELOCATION OF BATHROOM, POWDER ROOM, KITCHEN, W/ ELECTRICAL HOT WATER HEATERS FOR NEW FIXTURES ON EXIST'G ROUGHINGS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY
B01136501-I1
11/15/2021
Objection raised — Inspections
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Other
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Admin
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Fire_Protection
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Other
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Scope
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Fire_Protection
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Other
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Inspections
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Zoning
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/15/2021
Objection raised — Structural
11/15/2021
Objection resolved — Addressed
11/11/2021
Filed — Alteration
MINOR NON LOAD BEARING PARTITION WORK. REPAIR FLOORING WHERE REQUIRED. NO CHANGE IN USE EGRESS OR OCCUPANCY
B00621472-I1
11/11/2021
Special inspection requirement — Interior lighting power
Brent Porter
10/29/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brent Porter
10/29/2021
Special inspection requirement — Final
Brent Porter
03/19/2014
Violation issued (ECB, closed)
Construction
03/19/2014
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedMITIE PLUMBING & HTG CORP03/18/2026
1 project · most recent 04/24/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/24/2026Permit IssuedINNOVATIVE HEATING SOLUTIGas, Water/Sanitary
1 project · most recent 03/09/2021
FiledStatusContractorScope
03/09/2021Permit IssuedMATTISON ELECTRIC, INC—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
04/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/03/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/03/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/22/2026Fire-Resistant Penetrations and JointsBrent Porterspecial
04/14/2026Fire-Resistant Penetrations and JointsBrent Porterspecial
11/11/2021Interior lighting powerBrent Porterenergy_progress
10/29/2021Fire-Resistant Penetrations and JointsBrent Porterspecial
10/29/2021FinalBrent Porterprogress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026B01136501-P2Request digital key ↗
08/20/2026B01136501-I1Request digital key ↗
08/20/2026B01136501-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/31/2026B00621472-I1Open ↗
08/20/2026B01136501-P2Open ↗
08/20/2026B01136501-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026B01136501-P2Open ↗
08/26/2026B01136501-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026B00621472-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/20/2026B01136501-P1Open ↗
08/20/2026B01136501-P2Open ↗
08/20/2026B01136501-I1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/14/2026B00621472-I1Open ↗