← Back
Primarily 2 family with 1 store or office
113-11 LIBERTY AVENUE
QUEENS · South Ozone Park · BIN 4201886
💬 Discuss this project
1920Year Built
2Stories
S2Building Class
R6BZoning
2,090 sfGross Floor Area
3Units
3 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 1,863 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction23p · 1 filing · 20 docs
Floor 3Under Construction27p · 1 filing · 20 docs
Floor 2Under Construction23p · 1 filing · 20 docs
Floor 1Under Construction23p · 1 filing · 20 docs
CellarUnder Construction27p · 1 filing · 20 docs
Site & exteriorUnder Construction40p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KAIETEUR CONSTRUCTION103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC1409/11/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NASIR J. KHANZADA LLC2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAIETEUR CONSTRUCTION INC.General Contractor609/15/2026
UNIQUE FIRE SYSTEMS INCGeneral Contractor107/01/2026
M & M PIPING AND HEATINGPlumbing106/28/2026
WATERMARK PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC15271309/11/2026
TRIANGLE INSPECTION & TES7495309/11/2026
Building Lifecycle
All (77)Filed (13)Permit Issued (9)Signed Off (1)Violation (7)Inspection (11)Objection (6)Special Inspection (30)
09/14/2026
Permit issued — Structural
Q01107243-I1-GC-CX
09/11/2026
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P8
09/11/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
09/11/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Nasir Khanzada
09/11/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
09/11/2026
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
09/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
08/03/2026
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P7
07/31/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Nasir Khanzada
07/31/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
07/31/2026
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
07/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
07/31/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
07/08/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/03/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/02/2026
Permit issued — Mechanical Systems
Q01107243-S6-MS
06/30/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/29/2026
Permit issued — Mechanical Systems
Q01107243-S5-MS
05/22/2026
Permit issued — Mechanical Systems
Q01107243-S5-MS
05/22/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/22/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/11/2026
Special inspection requirement — Lighting in dwelling units
Nasir Khanzada
05/11/2026
Special inspection requirement — Insulation placement and R values
Nasir Khanzada
05/11/2026
Special inspection requirement — Fenestration areas
Nasir Khanzada
05/11/2026
Special inspection requirement — Fenestration air leakage
Nasir Khanzada
05/11/2026
Special inspection requirement — Air barrier - visual inspection
Nasir Khanzada
05/11/2026
Special inspection requirement — Metering
Nasir Khanzada
05/11/2026
Special inspection requirement — Footing and Foundation
Nasir Khanzada
05/11/2026
Special inspection requirement — Structural Steel - Welding
Nasir Khanzada
05/11/2026
Special inspection requirement — Structural Steel - Details
Nasir Khanzada
05/11/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
05/11/2026
Special inspection requirement — Final
Nasir Khanzada
05/11/2026
Special inspection requirement — Fire-Resistance Rated Construction
Nasir Khanzada
05/11/2026
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
05/11/2026
Special inspection requirement — Lighting controls
Nasir Khanzada
05/11/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Nasir Khanzada
05/11/2026
Special inspection requirement — Protection of exposed foundation insulation
Nasir Khanzada
05/11/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Nasir Khanzada
05/11/2026
Special inspection requirement — Maintenance information
Nasir Khanzada
05/11/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
05/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
04/27/2026
Permit issued — Plumbing
Q01107243-S2-PL
04/08/2026
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-S6
03/06/2026
Permit issued — Support of Excavation
Q01107243-S4-SE
03/02/2026
Objection resolved — Resolved
02/05/2026
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P6
01/27/2026
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P2
01/22/2026
Signed off — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-S1
01/02/2026
Objection raised — Energy
11/17/2025
Objection resolved — Addressed
11/14/2025
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P5
10/20/2025
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P1
10/02/2025
Objection raised — Scope
09/17/2025
Violation issued (ECB, closed)
Construction
09/16/2025
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-P4
09/11/2025
Filed — Alteration CO
PLUMBING FILING IN CONJUNCTION WITH ALT-1 FILING TO ENLARGETHE 1ST. FLOOR AND ADD A NEW THIRD FLOOR.
Q01107243-S5
07/25/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedKAIETEUR CONSTRUCTION INC.09/14/2026
DOB NOWMechanical SystemsPermit IssuedKAIETEUR CONSTRUCTION INC.07/02/2026
DOB NOWMechanical SystemsPermit IssuedKAIETEUR CONSTRUCTION INC.06/29/2026
DOB NOWMechanical SystemsPermit IssuedUNIQUE FIRE SYSTEMS INC05/22/2026
DOB NOWPlumbingPermit IssuedM & M PIPING AND HEATING04/27/2026
DOB NOWSupport of ExcavationPermit IssuedKAIETEUR CONSTRUCTION INC03/06/2026
DOB NOWPlumbingPermit IssuedWATERMARK PLUMBING CORP05/06/2025
DOB NOWStructuralPermit IssuedKAIETEUR CONSTRUCTION INC04/24/2025
DOB NOWConstruction FenceSigned-offKAIETEUR CONSTRUCTION INC04/16/2025
BIS—ISSUEDNEW YORK SIGN CITY INC08/20/2003
1 project · most recent 09/11/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/11/2026Permit IssuedKAIETEUR CONSTRUCTION INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Fujitsu AOUH36KWAS4 36,000 BTU · Condensing Unit ×1
International Comfort Products RGVO61KFFA0AAAA 60,000 BTU · Condensing Unit ×1
Ventilation
Dayton DAYTON 56JN95 8,000 CFM · Exhaust Fan ×1
1 project · most recent 09/11/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/11/2026Permit IssuedM & M PIPING AND HEATINGGas, Storm, Water/Sanitary
1 project · most recent 07/27/2026
General Wiring
FiledStatusContractorScope
07/27/2026CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 09/11/2026
Steel Concrete Wood
FiledStatusContractorScope
09/11/2026Permit IssuedKAIETEUR CONSTRUCTION INCSteel, Concrete, Wood
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
07/08/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/03/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/30/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/22/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/22/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/22/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/22/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/25/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/17/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 144
DateRequirementInspectorRole
09/11/2026Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
09/11/2026Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
09/11/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationNasir Khanzadaspecial
09/11/2026Energy Code Compliance InspectionsNasir Khanzadaprogress
09/11/2026Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
07/31/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationNasir Khanzadaspecial
07/31/2026Energy Code Compliance InspectionsNasir Khanzadaprogress
07/31/2026Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
07/31/2026Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
07/31/2026Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
05/11/2026Footing and FoundationNasir Khanzadaprogress
05/11/2026Subgrade InspectionsNasir Khanzadaspecial
05/11/2026Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
05/11/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationNasir Khanzadaspecial
05/11/2026Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
05/11/2026MasonryNasir Khanzadaspecial
05/11/2026Structural Steel - DetailsNasir Khanzadaspecial
05/11/2026Structural Steel - WeldingNasir Khanzadaspecial
05/11/2026Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
05/11/2026FinalNasir Khanzadaprogress
05/11/2026Fire-Resistance Rated ConstructionNasir Khanzadaprogress
05/11/2026Energy Code Compliance InspectionsNasir Khanzadaprogress
05/11/2026Interior lighting powerNasir Khanzadaenergy_progress
05/11/2026Fenestration air leakageNasir Khanzadaenergy_progress
05/11/2026Lighting controlsNasir Khanzadaenergy_progress
Latest 25 of 144.
▾Documents — 114 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/18/2026Q01107243-S2Request digital key ↗
08/18/2026Q01107243-S1Request digital key ↗
08/18/2026Q01107243-I1Request digital key ↗
Showing 3 of 13 on file for this type
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZD1: DOB Zoning Diagram5
08/18/2026Q01107243-I1Open ↗
08/13/2026Q01107243-P3Open ↗
08/13/2026Q01107243-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp4
08/13/2026Q01107243-I1Open ↗
08/13/2026Q01107243-P1Open ↗
08/13/2026Q01107243-P3Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications55
▸DOB NOWSpecial Inspector Seal & Signature22
09/23/2026Q01107243-S5Open ↗
09/02/2026Q01107243-P7Open ↗
09/02/2026Q01107243-P7Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWProgress Inspector Seal & Signature20
09/23/2026Q01107243-S5Open ↗
09/23/2026Q01107243-S5Open ↗
09/02/2026Q01107243-P7Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/18/2026Q01107243-P7Open ↗
08/18/2026Q01107243-S6Open ↗
08/13/2026Q01107243-P4Open ↗
Showing 3 of 13 on file for this type
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist4
08/13/2026Q01107243-P2Open ↗
08/13/2026Q01107243-P1Open ↗
08/13/2026Q01107243-I1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports14
▸DOB NOWSOIL REPORT10
08/18/2026Q01107243-P7Open ↗
08/13/2026Q01107243-P4Open ↗
08/13/2026Q01107243-P5Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram3
08/13/2026Q01107243-S2Open ↗
08/13/2026Q01107243-S4Open ↗
08/13/2026Q01107243-I1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01107243-I1Open ↗
▸Other Documents19
▸DOB NOWPlot Diagram5
08/13/2026Q01107243-S4Open ↗
08/13/2026Q01107243-P3Open ↗
08/13/2026Q01107243-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026Q01107243-P3Open ↗
08/13/2026Q01107243-P1Open ↗
08/13/2026Q01107243-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026Q01107243-P3Open ↗
08/13/2026Q01107243-P2Open ↗
08/13/2026Q01107243-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/13/2026Q01107243-P1Open ↗
08/13/2026Q01107243-P3Open ↗
08/13/2026Q01107243-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/13/2026Q01107243-I1Open ↗
08/13/2026Q01107243-S4Open ↗