← Back
Walk-up apt, over six families with stores
113 7 AVENUE SOUTH
MANHATTAN · West Village · BIN 1082223
💬 Discuss this project
1915Year Built
3Stories
C7Building Class
C4-5Zoning
21,100 sfGross Floor Area
31Units
Rent Stabilized8 Open Violations 7 unresolved · 1 paperwork only ▸FDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: CHRISTOPHER & SEVENTH REALTY LLC · 9,565 sf lot · 2.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction83p · 7 filings · 20 docs
Floor 4Under Construction90p · 6 filings · 20 docs
Floor 357p · 4 filings · 20 docs
Floor 258p · 4 filings · 20 docs
Floor 155p · 4 filings · 20 docs
Cellar11p · 2 filings · 20 docs
Basement1p · 1 filing · 7 docs
Sub-Basement16p · 3 filings · 20 docs
Site & exteriorUnder Construction17p · 4 filings · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHRISTOPHER 7TH REALTY303/21/2026
51 LLC103/21/2026
CHRISTOPHER & SEVENTH REALTY LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/01/2015$56.5M—— → —$2,678/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CBK ENGINEERING602/10/2026
EDG1210/01/2025
RIGID STRUCTURAL DESIGN, LLC110/07/2024
LUKE LICALZI, P.E., P.C.805/14/2024
ENTHINK ENGINEERS LLC210/25/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EDI CONSULTING GROUP2803/21/2026
LMS-ACE SERVICES1103/21/2026
Rigid Structural Design, LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ABC RESTORATION INCGeneral Contractor1607/08/2026
DC PROJECTS INCGeneral Contractor1307/02/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor807/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing707/08/2026
AIRCRAFT AIR COND CORPGeneral Contractor604/09/2026
M GROUP MANAGEMENT CORPGeneral Contractor303/21/2026
INTERSYSTEMS INSTAL S&SGeneral Contractor204/09/2026
INTERSYSTEM CONSTRUCTIONGeneral Contractor104/09/2026
BOROWIDE ELECT'L CONTR'SElectrical103/22/2026
CASE PLUMBINGPlumbing103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
H2 CONSULTING PE PC835702/10/2026
EDG25781210/01/2025
GZ & NC CODE CONSULTING P7492308/22/2024
JON LIBASCI3068604/24/2024
Building Lifecycle
All (204)Filed (29)Permit Issued (40)Signed Off (11)Violation (60)Inspection (6)Objection (28)Special Inspection (30)
08/17/2026
Signed off — Alteration
M01120886-I1
07/15/2026
Signed off — Alteration
PROPOSED INTERIOR DWELLING UNIT, STAIR AND ROOF RENOVATION AS PER PLANS SUBMITTED HEREWITH. THERE IS NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01032650-I1
06/30/2026
Permit issued — General Construction
M01032715-I1-GC-CX
06/30/2026
Permit issued — General Construction
M01084523-I1-GC
04/22/2026
Signed off — Alteration
M01023471-I1
03/17/2026
Permit issued — Structural
M01032650-I1-GC
03/17/2026
Permit issued — Structural
M01032650-I1-ST
03/13/2026
Signed off — Alteration
M01023471-S1
02/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Harry Hong
02/24/2026
Special inspection requirement — Tenant Protection Plan Compliance
02/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Harry Hong
02/23/2026
Special inspection requirement — Final
Harry Hong
02/23/2026
Special inspection requirement — Mechanical Systems
Harry Hong
02/23/2026
Special inspection requirement — Tenant Protection Plan Compliance
Harry Hong
02/10/2026
Filed — Alteration
PLUMBING WORK IN CONJUNCTION WITH APT. 5B RENOVATION, AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M01221378-P1
02/10/2026
Filed — Alteration
M01023471-P1
02/10/2026
Filed — Alteration
M01023471-P2
01/26/2026
Special inspection requirement — Mechanical Systems
Harry Hong
01/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Harry Hong
01/26/2026
Special inspection requirement — Tenant Protection Plan Compliance
01/26/2026
Special inspection requirement — Final
Harry Hong
01/26/2026
Special inspection requirement — Tenant Protection Plan Compliance
01/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Harry Hong
01/20/2026
Signed off — Alteration
PROPOSED INTERIOR STRUCTURAL REPAIRS TO AN EXISTING BUILDING (EXISTING CO CO #67163) AT CELLAR TO 3RD FLOORS AS PER PLANS SUBMITTED HEREWITH. THERE IS NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00815354-I1
01/16/2026
Signed off — Alteration
M08021117-I1
01/16/2026
Permit issued — Supported Scaffold
M01120886-I1-SF
01/15/2026
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/21/2025
Signed off — Alteration
INTERIOR RENOVATION TO APTS. 2A, 2B, 3A, 3B, 4A & 4B ON 01-03 FLOORS. RESTORATION, MINOR PARTITION WORK AND FINISHES, AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00930082-I1
11/21/2025
Violation issued (ECB, closed)
Construction
11/21/2025
Violation issued (ECB, closed)
Unknown
11/20/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/13/2025
Signed off — Alteration
INTERIOR RENOVATION TO APTS. 2A, 2B, 3A, 3B, 4A & 4B ON 01-03 FLOORS. RESTORATION, MINOR PARTITION WORK AND FINISHES, AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00930082-S1
10/24/2025
Signed off — Alteration
INTERIOR RENOVATION TO INTERIOR STAIR/ PUBLIC CORRIDORS. MINOR PARTITION WORK, AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M08049616-I1
10/23/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/22/2025
Special inspection requirement — Final
Anthony Stasio
10/22/2025
Special inspection requirement — Concrete - Cast-In-Place
Anthony Stasio
10/22/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Anthony Stasio
10/22/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Anthony Stasio
10/22/2025
Special inspection requirement — Masonry
Anthony Stasio
10/22/2025
Special inspection requirement — Fenestration air leakage
Anthony Stasio
10/22/2025
Special inspection requirement — Post-installed Anchors
Anthony Stasio
10/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Anthony Stasio
10/22/2025
Special inspection requirement — Insulation placement and R values
Anthony Stasio
10/22/2025
Special inspection requirement — Tenant Protection Plan Compliance
Nazzareno Callipo
10/22/2025
Special inspection requirement — Structural Cold-Formed Steel
Anthony Stasio
10/22/2025
Special inspection requirement — Air barrier - visual inspection
Anthony Stasio
10/22/2025
Special inspection requirement — Fenestration areas
Anthony Stasio
10/16/2025
Objection resolved — Addressed
10/15/2025
Permit issued — Sidewalk Shed
M08026909-I1-SH
10/14/2025
Objection raised — Scope
10/09/2025
Permit issued — Supported Scaffold
M01120886-I1-SF
10/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Anthony Stasio
10/03/2025
Special inspection requirement — Lighting in dwelling units
Anthony Stasio
10/03/2025
Special inspection requirement — Final
Anthony Stasio
10/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Anthony Stasio
10/03/2025
Special inspection requirement — Tenant Protection Plan Compliance
Nazzareno Callipo
10/01/2025
Filed — Alteration
THE SCOPE OF WORK IS RENOVATION OF ROOF AND ENLARGEMENT OF EXISTING ATTIC SPACE. MECHANICAL IS FILED UNDER A SEPARATE APPLICATION DOB# M01023471..
M01032715-P2
09/30/2025
Filed — Alteration
PROPOSED INTERIOR DWELLING UNIT, STAIR AND ROOF RENOVATION AS PER PLANS SUBMITTED HEREWITH. THERE IS NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01032650-P1
09/03/2025
Violation issued (HPD, closed)
A
09/03/2025
Violation issued (HPD, closed)
A
Latest 60 of 204 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS INC06/30/2026
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS INC06/30/2026
DOB NOWStructuralSigned-offABC RESTORATION INC03/17/2026
DOB NOWStructuralSigned-offABC RESTORATION INC03/17/2026
DOB NOWSupported ScaffoldSigned-offINTERSYSTEM CONSTRUCTION01/16/2026
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC10/15/2025
DOB NOWSupported ScaffoldSigned-offINTERSYSTEMS INSTAL S&S10/09/2025
DOB NOWPlumbingPermit IssuedJOHN FITZGERALD PLBG &HTG08/18/2025
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND07/21/2025
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND07/21/2025
DOB NOWStructuralPermit IssuedDC PROJECTS07/17/2025
DOB NOWGeneral ConstructionSigned-offDC PROJECTS06/24/2025
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS06/24/2025
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS06/24/2025
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/25/2025
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/25/2025
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/25/2025
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/24/2025
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND02/19/2025
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND02/19/2025
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS02/11/2025
DOB NOWGeneral ConstructionPermit IssuedDC PROJECTS01/22/2025
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND11/18/2024
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC10/21/2024
DOB NOWSupported ScaffoldSigned-offINTERSYSTEMS INSTAL S&S10/08/2024
DOB NOWMechanical SystemsSigned-offAIRCRAFT AIR COND08/12/2024
DOB NOWGeneral ConstructionSigned-offDC PROJECTS08/01/2024
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG06/28/2024
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/22/2024
DOB NOWStructuralSigned-offABC RESTORATION INC02/22/2024
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/12/2024
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC10/24/2023
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC10/24/2023
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC10/17/2023
DOB NOWGeneral ConstructionSigned-offM GROUP MANAGEMENT CORP08/18/2023
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC03/31/2023
DOB NOWStructuralSigned-offABC RESTORATION INC03/20/2023
DOB NOWGeneral ConstructionSigned-offABC RESTORATION INC02/01/2023
DOB NOWSupported ScaffoldSigned-offANDAMIO SCAFFOLDING LLC10/28/2022
DOB NOWSidewalk ShedPermit IssuedANDAMIO SCAFFOLDING LLC10/28/2022
+ 9 more permits on file
1 project · most recent 02/10/2026
Water/Sanitary
FiledStatusContractorScope
02/10/2026Permit IssuedJOHN FITZGERALD PLBG &HTGWater/Sanitary
5 projects · most recent 06/24/2024
General Wiring
FiledStatusContractorScope
06/24/2024Permit IssuedMONTGOMERY ELEC'L CONTR'G8 meters, 8 new_meters
12/14/2023Permit IssuedMONTGOMERY ELEC'L CONTR'G—
12/14/2023Permit IssuedMONTGOMERY ELEC'L CONTR'GGeneral Wiring
10/28/2022Permit IssuedBOROWIDE ELECT'L CONTR'S—
07/05/2022Permit IssuedALL WAYS ELECTRIC CORP.W—
2 projects · most recent 10/01/2025
Concrete
FiledStatusContractorScope
10/01/2025Permit IssuedDC PROJECTS INCConcrete
09/30/2025Signed-offABC RESTORATION INC1 scope_items
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
11/20/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/23/2025Pass-Final General Construction Non-Directive 14PassView ↗
02/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/24/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 107
DateRequirementInspectorRole
02/24/2026Fire-Resistant Penetrations and JointsHarry Hongspecial
02/24/2026Tenant Protection Plan Compliance—special
02/23/2026Tenant Protection Plan ComplianceHarry Hongspecial
02/23/2026FinalHarry Hongprogress
02/23/2026Mechanical SystemsHarry Hongspecial
02/23/2026Fire-Resistant Penetrations and JointsHarry Hongspecial
01/26/2026Tenant Protection Plan Compliance—special
01/26/2026Mechanical SystemsHarry Hongspecial
01/26/2026Fire-Resistant Penetrations and JointsHarry Hongspecial
01/26/2026Tenant Protection Plan Compliance—special
01/26/2026Fire-Resistant Penetrations and JointsHarry Hongspecial
01/26/2026FinalHarry Hongprogress
10/22/2025Post-installed AnchorsAnthony Stasiospecial
10/22/2025Structural Cold-Formed SteelAnthony Stasiospecial
10/22/2025Tenant Protection Plan ComplianceNazzareno Callipospecial
10/22/2025Fire-Resistant Penetrations and JointsAnthony Stasiospecial
10/22/2025Fenestration air leakageAnthony Stasioenergy_progress
10/22/2025Air barrier - visual inspectionAnthony Stasioenergy_progress
10/22/2025Fenestration and door U-factor and product ratingsAnthony Stasioenergy_progress
10/22/2025Insulation placement and R valuesAnthony Stasioenergy_progress
10/22/2025FinalAnthony Stasioprogress
10/22/2025Concrete - Cast-In-PlaceAnthony Stasiospecial
10/22/2025MasonryAnthony Stasiospecial
10/22/2025Structural Stability – Alterations of existing buildingsAnthony Stasiospecial
10/22/2025Fenestration areasAnthony Stasioenergy_progress
Latest 25 of 107.
▾Documents — 246 on file (BIS + DOB NOW)
▸Plans & Drawings29
▸DOB NOWPlans/Sketch29
09/01/2026M08021117-I1Request digital key ↗
09/01/2026M08026910-I1Request digital key ↗
09/01/2026M08026909-I1Request digital key ↗
Showing 3 of 29 on file for this type
▸Applications & Permits36
▸DOB NOWLPC Approval/Permit26
08/30/2026M00815354-I1Open ↗
08/30/2026M00815354-P1Open ↗
08/30/2026M00815354-P2Open ↗
Showing 3 of 26 on file for this type
▸BISWORK PERMIT APPLICATION8
02/25/2016122685969Open ↗
02/25/2016122685969Open ↗
07/25/2014140155640Open ↗
Showing 3 of 8 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
02/25/2016122685969Open ↗
01/23/2014140155640Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026M01032715-P1Open ↗
08/13/2026M01032715-I1Open ↗
08/13/2026M01032715-P2Open ↗
▸Seals & Professional Certifications104
▸DOB NOWProgress Inspector Seal & Signature33
09/29/2026M01032650-I1Open ↗
09/29/2026M01032650-I1Open ↗
09/19/2026M01023471-P2Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature33
09/29/2026M01032650-I1Open ↗
09/29/2026M01032650-I1Open ↗
09/19/2026M01023471-P2Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature29
09/01/2026M08049616-I1Open ↗
09/01/2026M08049616-P2Open ↗
09/01/2026M08049616-P1Open ↗
Showing 3 of 29 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
06/01/2016122685969Open ↗
02/22/2016122685969Open ↗
02/05/2015140155640Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
02/22/2016122685969Open ↗
01/23/2014140155640Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/22/2016122685969Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/23/2014140155640Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
01/23/2014140155640Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
02/22/2016122685969Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
10/22/2014140155640Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
10/22/2014140155640Open ↗
▸BISSCHEDULE B - PLUMBING1
01/23/2014140155640Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
01/23/2014140155640Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/22/2016122685969Open ↗
▸BISTenant Protection Plan and Notes1
02/22/2016122685969Open ↗
▸Environmental & Asbestos27
▸DOB NOWDEP ACP-5: Asbestos Assessment Report22
09/01/2026M08049616-P1Open ↗
09/01/2026M08049616-P2Open ↗
08/31/2026M00839484-I1Open ↗
Showing 3 of 22 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
02/25/2016122685969Open ↗
02/25/2016122685969Open ↗
01/23/2014140155640Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/13/2026M08021117-I1Open ↗
08/13/2026M01032715-I1Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
06/01/2016122685969Open ↗
02/22/2016122685969Open ↗
02/05/2015140155640Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
06/01/2016122685969Open ↗
02/05/2015140155640Open ↗
11/25/2014140155640Open ↗
▸DOB NOWPreliminary Commissioning Report Certification2
08/25/2026M01023471-I1Open ↗
08/13/2026M01023471-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
01/23/2014140155640Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
01/23/2014140155640Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
01/23/2014140155640Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
06/01/2016122685969Open ↗
02/05/2015140155640Open ↗
11/25/2014140155640Open ↗
▸BISSUPERSEDING LETTER2
05/06/2014140155640Open ↗
05/06/2014140155640Open ↗
▸BISLANDMARKS APPROVAL2
02/25/2016122685969Open ↗
01/23/2014140155640Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/25/2014140155640Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT5
06/01/2016122685969Open ↗
02/22/2016122685969Open ↗
02/05/2015140155640Open ↗
Showing 3 of 5 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
02/25/2016122685969Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET1
02/22/2016122685969Open ↗
▸BISADDITIONAL INFORMATION1
08/20/2014140155640Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/23/2014140155640Open ↗
▸Other Documents11
▸DOB NOWSite Survey: Initial3
08/13/2026M01032715-I1Open ↗
08/13/2026M01032715-P2Open ↗
08/13/2026M01032715-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026M01032715-I1Open ↗
08/13/2026M01032715-P2Open ↗
08/13/2026M01032715-P1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026M01032715-P1Open ↗
08/13/2026M01032715-P2Open ↗
08/13/2026M01032715-I1Open ↗
▸DOB NOWProof of Historic Building2
08/19/2026M01221378-I1Open ↗
08/13/2026M01221378-P1Open ↗