← Back
Five to six families
113 EAGLE STREET
BROOKLYN · BIN 3321383
💬 Discuss this project
1930Year Built
3Stories
C2Building Class
R6BZoning
2,280 sfGross Floor Area
5Units
Rent Stabilized6 Open Violations ▸FDNY Report ↗
Five to six families · 2,500 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 2Under Construction9p · 1 filing · 20 docs
Floor 1Under Construction6p · 1 filing · 20 docs
CellarUnder Construction10p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/18/2026$2.6M—Private party → 113 EAGLE LLC$1,140/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.306/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JACK JAFFA & ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BEE CONSTRUCTIONS LLCGeneral Contractor104/09/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BIZ DESIGNS LLC6312306/04/2026
AZ PROFESSIONAL ENGINEERI766206/03/2026
Building Lifecycle
All (30)Filed (3)Permit Issued (2)Inspection (4)Special Inspection (21)
06/17/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/16/2026
Permit issued — Plumbing
B01370320-S1-PL
06/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
06/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
06/05/2026
Special inspection requirement — Final
Feng Zhang
06/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jeff Akerman
06/05/2026
Special inspection requirement — Energy Code Compliance Inspections
Jeff Akerman
06/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Jeff Akerman
06/05/2026
Special inspection requirement — Insulation placement and R values
Jeff Akerman
06/05/2026
Special inspection requirement — Air barrier - visual inspection
Jeff Akerman
06/05/2026
Special inspection requirement — Fenestration air leakage
Jeff Akerman
06/05/2026
Special inspection requirement — Interior lighting power
Jeff Akerman
06/04/2026
Filed — Alteration
Interior renovation as shown on plans filed herewith.
B01370320-S1
06/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
06/03/2026
Filed — Alteration
Interior renovation as shown on plans filed herewith.
B01370320-P1
06/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeff Akerman
06/01/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
VIJAY KUMAR
06/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Jeff Akerman
06/01/2026
Special inspection requirement — Final
Feng Zhang
06/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jeff Akerman
06/01/2026
Special inspection requirement — Air barrier - visual inspection
Jeff Akerman
06/01/2026
Special inspection requirement — Insulation placement and R values
Jeff Akerman
06/01/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Jeff Akerman
06/01/2026
Special inspection requirement — Interior lighting power
Jeff Akerman
06/01/2026
Special inspection requirement — Fenestration air leakage
Jeff Akerman
03/17/2026
Permit issued — General Construction
B01370320-I1-GC
03/12/2026
Filed — Alteration
Interior renovation as shown on plans filed herewith.
B01370320-I1
11/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG06/16/2026
DOB NOWGeneral ConstructionPermit IssuedBEE CONSTRUCTIONS LLC03/17/2026
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/17/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/31/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
06/05/2026Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
06/05/2026Fire-Resistant Penetrations and JointsJeff Akermanspecial
06/05/2026FinalFeng Zhangprogress
06/05/2026Fire-Resistance Rated ConstructionJeff Akermanprogress
06/05/2026Energy Code Compliance InspectionsJeff Akermanprogress
06/05/2026Fenestration and door U-factor and product ratingsJeff Akermanenergy_progress
06/05/2026Insulation placement and R valuesJeff Akermanenergy_progress
06/05/2026Air barrier - visual inspectionJeff Akermanenergy_progress
06/05/2026Fenestration air leakageJeff Akermanenergy_progress
06/05/2026Interior lighting powerJeff Akermanenergy_progress
06/04/2026Fire-Resistant Penetrations and JointsJeff Akermanspecial
06/01/2026Fire-Resistant Penetrations and JointsJeff Akermanspecial
06/01/2026Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
06/01/2026Energy Code Compliance InspectionsJeff Akermanprogress
06/01/2026FinalFeng Zhangprogress
06/01/2026Fire-Resistance Rated ConstructionJeff Akermanprogress
06/01/2026Air barrier - visual inspectionJeff Akermanenergy_progress
06/01/2026Insulation placement and R valuesJeff Akermanenergy_progress
06/01/2026Fenestration and door U-factor and product ratingsJeff Akermanenergy_progress
06/01/2026Interior lighting powerJeff Akermanenergy_progress
06/01/2026Fenestration air leakageJeff Akermanenergy_progress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/16/2026B01370320-S1Request digital key ↗
08/16/2026B01370320-I1Request digital key ↗
08/16/2026B01370320-P1Request digital key ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature6
08/26/2026B01370320-I1Open ↗
08/26/2026B01370320-I1Open ↗
08/26/2026B01370320-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/26/2026B01370320-I1Open ↗
08/26/2026B01370320-I1Open ↗
08/25/2026B01370320-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/16/2026B01370320-S1Open ↗
08/16/2026B01370320-P1Open ↗
08/16/2026B01370320-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/16/2026B01370320-P1Open ↗
08/16/2026B01370320-S1Open ↗
08/16/2026B01370320-I1Open ↗