← Back
Miscellaneous warehouse
113 LOMBARDY STREET
BROOKLYN · BIN 3069714
💬 Discuss this project
1950Year Built
1Stories
E9Building Class
M1-1Zoning
4,500 sfGross Floor Area
1Units
12 Open Violations ▸FDNY Report ↗
Miscellaneous warehouse · Owner of record: 113 LOMBARDY NY LLC · 5,000 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TIME MARBLE AND GRANITE INC403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/02/2018$1.9M—— → —$433/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EAST + WEST ARCHITECTURE PC101/24/2024
AECOM209/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WALTER T GORMAN PE403/21/2026
XUX CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AECOM USA INCGeneral Contractor307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WALTER T. GORMAN, P.E., P268209/23/2021
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Signed Off (1)Violation (12)Objection (5)Special Inspection (4)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/29/2024
Objection resolved — Resolved
01/26/2024
Objection raised — Other
01/26/2024
Objection raised — Scope
01/26/2024
Objection raised — Scope
01/26/2024
Objection raised — Scope
01/24/2024
Filed — Alteration
Mechanical work of existing commercial space, The work is to be done at first floor. No change to occupancy, use and egress. Plumbing filed under DOB Now Build #B00977539-I1
B00977535-I1
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/06/2023
Signed off — Alteration
Propose to file for sub-slab depressurization system design. No change to use, egress or occupancy.
B00464670-I1
09/27/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walter Gorman
09/27/2021
Special inspection requirement — Final
Robert Forstner
09/23/2021
Filed — Alteration
Propose to file for sub-slab depressurization system design. No change to use, egress or occupancy.
B00464670-P1
08/26/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walter Gorman
08/26/2021
Special inspection requirement — Final
DONALD MCCALL
05/24/2021
Permit issued — General Construction
B00464670-I1-GC
02/17/2021
Permit issued — General Construction
B00464670-I1-GC
02/08/2021
Filed — Alteration
Propose to file for sub-slab depressurization system design. No change to use, egress or occupancy.
B00464670-I1
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/24/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/01/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/26/2002
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAECOM USA INC05/24/2021
DOB NOWGeneral ConstructionSigned-offAECOM USA INC02/17/2021
BISPLISSUEDORION PLUMBING & HTG CORP05/11/2015
BISOTISSUEDGLOBAL GROUP INDUSTRIES C05/11/2015
BISOTISSUEDBIG APPLE CARBONIC CORPORATION03/16/1995
1 project · most recent 01/24/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/24/2024——Heating and Air Conditioning Systems
Heat / Cool
Gree NEO36HP230V1AO 34,600 BTU · Heat Pump Outdoor ×4
UMAT42HP230V1AO 44,000 BTU · Heat Pump Outdoor ×2
VIR36HP230V1BO 34,600 BTU · Heat Pump Outdoor ×2
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
09/27/2021Fire-Resistant Penetrations and JointsWalter Gormanspecial
09/27/2021FinalRobert Forstnerprogress
08/26/2021Fire-Resistant Penetrations and JointsWalter Gormanspecial
08/26/2021FinalDONALD MCCALLprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - General Construction2
09/01/2026B00464670-P1Request digital key ↗
09/01/2026B00464670-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/15/2026B00977535-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
05/01/2015340254995Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00464670-I1Open ↗
09/01/2026B00464670-P1Open ↗
08/26/2026B00977535-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/19/2026B00464670-I1Open ↗
08/23/2026B00464670-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/19/2026B00464670-I1Open ↗
08/23/2026B00464670-P1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
05/01/2015340254995Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/01/2015340254995Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/01/2015340254995Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
05/01/2015340254995Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00464670-I1Open ↗
09/01/2026B00464670-P1Open ↗
08/15/2026B00977535-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/01/2015340254995Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
05/01/2015340254995Open ↗
05/01/2015340254995Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
05/01/2015340254995Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
05/01/2015340254995Open ↗
05/01/2015340254995Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/01/2015340254995Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
05/01/2015340254995Open ↗