← Back
BuildNYC
Converted dwellings or rooming house
1130 SHERMAN AVENUE
BRONX · BIN 2002649
💬 Discuss this project
1928Year Built
2Stories
C5Building Class
R7-1Zoning
5,483 sfGross Floor Area
8Units
Rent Stabilized6 Active Violations ▸
Converted dwellings or rooming house · Owner of record: 1130 Sherman · 3,300 sf lot · 1.66 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof24p · 1 filing · 20 docs
Floor 2Unit 2A, Unit 2B, Unit 2C +348p · 1 filing · 20 docs
Floor 1Unit 1, Unit 1A, Unit 1B +446p · 1 filing · 20 docs
Basement52p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1130 Sherman Avenue403/21/2026
1130 Sherman103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/26/2023$1.3M—1130 SHERMAN AVENUE CORP. → 1130 SHERMAN LLC$231/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Nikolai Katz Architect412/04/2023
Vasilios Artemiou PE911/01/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Express Filing2603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Builders Group USAGeneral Contractor203/21/2026
Nationwide MechanicalFire Protection103/21/2026
City Consultant EngineeringGeneral Contractor103/21/2026
Builders Group USAspecialty_contractor107/08/2026
A. M. Plumbing CompanyPlumbing107/08/2026
Nikolai KatzElectrical103/21/2026
Prime Piping & HeatingFire Protection107/08/2026
Cape PlumbingPlumbing207/02/2019
Carribean Sunset ConstructionGeneral Contractor505/03/2012
DOB ServicesGeneral Contractor106/10/2009
E.h.fire SuppressionFire Protection110/26/2011
First Choice PlumbingPlumbing909/23/2015
Joe Gina ContractingGeneral Contractor106/28/2013
Joe Parziale PlumbingPlumbing108/11/2016
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF Services56161012/04/2023
Building Lifecycle
08/02/2026
§ 27-2005 hmc: properly repair or replace the broken or defective latch set and its assemblies at building entrance door at public hall
HPD violation · closed
08/02/2026
§ 27-2005, 27-2007, 27-2041.1 hmc, §238, § 309; § 107 (2) ( c) mdl and 28 rcny §25-171: replace or repair the self-closing doors that is missing or…
HPD violation · closed
06/29/2026
§ 27-2005 hmc: properly repair or replace the broken or defective tempered glass panel creating a cut hazard at building entrance door at public hall
HPD violation · open
06/22/2026
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT BUILDING ENTGRANCE DOOR ( CUT HAZARD) , 1st STORY
HPD violation · open
06/10/2026
§ 27-2005, 27-2007, 27-2041.1 hmc, §238, § 309; § 107 (2) ( c) mdl and 28 rcny §25-171: replace or repair the self-closing doors that is missing or…
HPD violation · closed
139 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBuilders Group USA06/08/2023
DOB NOWSprinklersSigned-offAmb Mechanical06/01/2023
DOB NOWPlumbingSigned-offA. M. Plumbing Company06/01/2023
DOB NOWMechanical SystemsSigned-offBuilders Group USA06/01/2023
BISBLISSUEDCape Plumbing07/02/2019
BISPLISSUEDCape Plumbing11/26/2018
BIS—ISSUED1130 Sherman Avenue11/14/2017
BISPLISSUEDJoe Parziale Plumbing08/11/2016
BISBLISSUEDCity Consultant Engineering04/08/2016
BISPLISSUEDFirst Choice Plumbing09/23/2015
BISOTISSUEDCity Consultant Engineering09/09/2015
BISBLISSUEDFirst Choice Plumbing11/07/2014
BISPLISSUEDFirst Choice Plumbing09/03/2014
BISPLISSUEDFirst Choice Plumbing09/03/2014
BISSPISSUEDNationwide Mechanical01/07/2014
BISPLISSUEDFirst Choice Plumbing08/23/2013
BISPLISSUEDFirst Choice Plumbing08/23/2013
BIS—ISSUEDJoe Gina Contracting06/28/2013
BISSPISSUEDNationwide Mechanical12/17/2012
BISMHISSUEDCarribean Sunset Construction05/03/2012
BISPLISSUEDFirst Choice Plumbing11/14/2011
BISSPISSUEDE.h.fire Suppression10/26/2011
BISPLISSUEDFirst Choice Plumbing10/20/2011
BISOTISSUEDCarribean Sunset Construction10/13/2011
BISOTISSUEDCarribean Sunset Construction10/15/2010
BISOTISSUEDCarribean Sunset Construction09/30/2010
BISPLISSUEDFirst Choice Plumbing06/30/2010
BISOTISSUEDCarribean Sunset Construction06/07/2010
BIS—ISSUEDDOB Services06/10/2009
1 project · most recent 12/04/2023
Heating and Air Conditioning Systems
FiledStatusContractorScope
12/04/2023Permit IssuedBuilders Group USAHeating and Air Conditioning Systems
1 project · most recent 12/04/2023
Sprinkler System
FiledStatusContractorScope
12/04/2023Signed-offPrime Piping & HeatingSprinkler System
1 project · most recent 12/04/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
12/04/2023Signed-offA. M. Plumbing CompanyGas, Storm, Water/Sanitary
1 project · most recent 12/04/2023
General Wiring
FiledStatusContractorScope
12/04/2023CompleteTrue Power ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/24/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/12/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/10/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/15/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/30/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/22/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 84
DateRequirementInspectorRole
12/04/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
12/04/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
12/04/2023Fire-Resistance Rated ConstructionFAHAD FATEHprogress
12/04/2023Interior lighting powerFAHAD FATEHenergy_progress
12/04/2023MeteringFAHAD FATEHenergy_progress
12/04/2023Maintenance informationFAHAD FATEHenergy_progress
12/04/2023Fenestration air leakageFAHAD FATEHenergy_progress
12/04/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
12/04/2023Air barrier - visual inspectionFAHAD FATEHenergy_progress
12/04/2023Fenestration areasFAHAD FATEHenergy_progress
12/04/2023Insulation placement and R valuesFAHAD FATEHenergy_progress
11/13/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
11/13/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
11/13/2023Ventilation and air distribution systemFAHAD FATEHenergy_progress
11/13/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
11/13/2023FinalFAHAD FATEHprogress
11/13/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
11/13/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
11/13/2023Mechanical SystemsFAHAD FATEHspecial
11/01/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
11/01/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
11/01/2023Mechanical SystemsFAHAD FATEHspecial
11/01/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
11/01/2023FinalFAHAD FATEHprogress
11/01/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
Latest 25 of 84.
227 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account