← Back
BuildNYC
Two family brick
1134 BERGEN STREET
BROOKLYN · BIN 3030720
💬 Discuss this project
1897Year Built
3Stories
B1Building Class
R6Zoning
3,672 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family brick · 2,300 sf lot · 1.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofDemolition and construction cellar through roof4p · 2 filings · 20 docs
Floor 3Demolition and construction cellar through roof10p · 2 filings · 20 docs
Floor 2Demolition and construction cellar through roof10p · 2 filings · 20 docs
Floor 1Demolition and construction cellar through roof11p · 2 filings · 20 docs
CellarDemolition and construction cellar through roof14p · 2 filings · 20 docs
BasementDemolition and construction cellar through roof9p · 1 filing · 20 docs
Sub-Basement1p · 1 filing · 5 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/13/2015$1.8M—Private party → Private party$490/sf building
01/30/2014$1.3M—— → —$346/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mink Architecture311/29/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ganci Logozzo603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Big Bear Custom BuildGeneral Contractor807/08/2026
Litco ElectricElectrical103/22/2026
Top Dog Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Integrity Consulting Service666211/29/2023
Jack Green Associates422211/29/2023
Building Lifecycle
10/16/2026
Signed off — Alteration CO
RENOVATION ON BASEMENT AND 1ST FL, REPLACEMENT OF WINDOWS AT FRONT FACADE, REPAIR OF HISTORIC WINDOWS AT FRONT FACADE, NEW STEEL DECK AT REAR,LEGALIZE EXISITNG 1STORY REAR ADDITION. ALT 1 IS FOR RE-DESIGNATION OF FLOORS. EXISTING 2 DU. TO REMAIN 2 FAM DU.
B00722250-I1
06/15/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/14/2026
Permit renewed — Structural
Renewed without changes
B00722250-I1-GC
04/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACK GREEN
04/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
ALEKSANDR LEVIN
64 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedBig Bear Custom Build04/14/2026
DOB NOWGeneral ConstructionSigned-offBig Bear Custom Build09/14/2023
DOB NOWGeneral ConstructionPermit IssuedBig Bear Custom Build04/18/2023
DOB NOWPlumbingSigned-offTop Dog Plumbing & Heating02/04/2023
DOB NOWGeneral ConstructionPermit IssuedBig Bear Custom Build01/25/2023
1 project · most recent 02/06/2024
General Wiring
FiledStatusContractorScope
02/06/2024CompleteLitco ElectricGeneral Wiring
1 project · most recent 11/29/2023
Steel
FiledStatusContractorScope
11/29/2023Permit IssuedBig Bear Custom BuildSteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/15/2026Pass-Final CND-Occupancy InspectionPassView ↗
09/15/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/14/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/25/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/24/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
04/12/2024Fire-Resistant Penetrations and JointsJACK GREENspecial
04/12/2024Structural Stability – Alterations of existing buildingsALEKSANDR LEVINspecial
04/12/2024Structural Steel - DetailsALEKSANDR LEVINspecial
04/12/2024Post-installed AnchorsALEKSANDR LEVINspecial
04/12/2024Fire-Resistance Rated ConstructionMINK MCGILLICUDDYprogress
04/12/2024FinalMINK MCGILLICUDDYprogress
04/12/2024Fenestration air leakageMINK MCGILLICUDDYenergy_progress
04/12/2024Fenestration and door U-factor and product ratingsMINK MCGILLICUDDYenergy_progress
04/12/2024Insulation placement and R valuesMINK MCGILLICUDDYenergy_progress
11/28/2023Fire-Resistant Penetrations and JointsJACK GREENspecial
11/28/2023Post-installed AnchorsALEKSANDR LEVINspecial
11/28/2023Structural Stability – Alterations of existing buildingsALEKSANDR LEVINspecial
11/28/2023Structural Steel - DetailsALEKSANDR LEVINspecial
11/28/2023FinalMINK MCGILLICUDDYprogress
11/28/2023Fire-Resistance Rated ConstructionMINK MCGILLICUDDYprogress
11/28/2023Fenestration air leakageMINK MCGILLICUDDYenergy_progress
11/28/2023Insulation placement and R valuesMINK MCGILLICUDDYenergy_progress
11/28/2023Fenestration and door U-factor and product ratingsMINK MCGILLICUDDYenergy_progress
42 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account