22 Open Violations ▸FDNY Report ↗
Zoned residential, not Manhattan · Owner of record: PROMESA RESIDENTIAL HEALTH CARE FACILITY , INC. · 7,800 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof8p · 1 filing · 20 docs
Bulkhead5p · 1 filing · 20 docs
Floor 114p · 1 filing · 20 docs
Floor 103p · 1 filing · 20 docs
Floor 93p · 1 filing · 20 docs
Floor 813p · 1 filing · 20 docs
Floor 76p · 1 filing · 20 docs
Floor 63p · 1 filing · 20 docs
Floor 52p · 1 filing · 20 docs
Floor 42p · 1 filing · 20 docs
Floor 33p · 1 filing · 20 docs
Floor 211p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar11p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RODNEY D. GIBBLE CONSULTING ENGINEE205/19/2026
EP ENGINEERING LLC402/17/2026
DATTNER ARCHITECTS112/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1203/21/2026
Building Lifecycle
All (132)Filed (7)Violation (60)Objection (35)Special Inspection (30)
08/11/2026
Objection resolved — Resolved
06/03/2026
Objection raised — Other
05/19/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S3
05/14/2026
Objection resolved — Addressed
04/17/2026
Objection raised — Other
04/01/2026
Objection raised — Other
04/01/2026
Objection raised — Other
04/01/2026
Objection raised — Other
04/01/2026
Objection raised — Structural
04/01/2026
Objection raised — Other
04/01/2026
Objection raised — Other
04/01/2026
Objection raised — Admin
04/01/2026
Objection raised — Zoning
04/01/2026
Objection raised — Admin
04/01/2026
Objection raised — Structural
04/01/2026
Objection raised — Structural
04/01/2026
Objection raised — Inspections
03/24/2026
Objection resolved — Addressed
03/24/2026
Objection resolved — Addressed
03/24/2026
Objection resolved — Addressed
03/24/2026
Objection resolved — Addressed
03/24/2026
Objection resolved — Addressed
03/12/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S2
03/12/2026
Special inspection requirement — Post-installed Anchors
03/09/2026
Objection raised — Other
03/09/2026
Objection raised — Other
03/09/2026
Objection raised — Other
03/09/2026
Objection raised — Structural
03/09/2026
Objection raised — Other
03/09/2026
Objection resolved — Addressed
03/09/2026
Objection resolved — Addressed
03/08/2026
Objection raised — Mechanical
03/02/2026
Special inspection requirement — Structural Steel - Welding
03/02/2026
Special inspection requirement — Post-installed anchors in masonry
03/02/2026
Special inspection requirement — Structural Steel - High Strength Bolting
03/02/2026
Special inspection requirement — Concrete - Precast
03/02/2026
Special inspection requirement — Concrete – Prestressed
03/02/2026
Special inspection requirement — Masonry
03/02/2026
Special inspection requirement — Structural Steel - Details
02/18/2026
Objection resolved — Addressed
02/17/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S8
02/10/2026
Objection resolved — Addressed
02/06/2026
Objection raised — Other
02/06/2026
Objection raised — Other
02/06/2026
Objection raised — Other
02/06/2026
Objection raised — Other
01/21/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S6
01/21/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S5
01/21/2026
Filed — New Building
Mechanical filing as per plans filed
B01330190-S4
01/15/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
01/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/15/2026
Special inspection requirement — Post-installed Anchors
01/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/15/2026
Special inspection requirement — Shutoff dampers
01/15/2026
Special inspection requirement — Maintenance information
01/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
01/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
01/15/2026
Special inspection requirement — Electrical motors and elevators
01/15/2026
Special inspection requirement — HVAC-R and service water heating system controls
01/15/2026
Special inspection requirement — Duct leakage testing, insulation and design
Latest 60 of 132 events.
Nothing on file for this building.
1 project · most recent 05/19/2026
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/19/2026——Air Conditioning Systems, Ventilation Systems
Cooling
Daikin REYA96X 96,000 BTU · Vrf Outdoor ×2
FXFA30AAVJU 30,000 BTU · Vrf Indoor ×1
Ventacity VS1200 CME 850 CFM · Erv ×1
Ventilation
Swegon GOLD F RX 020 3,300 CFM · Erv ×2
GOLD F RX 005 580 CFM · Erv ×1
1 project · most recent 05/19/2026
Sprinkler System
FiledStatusContractorScope
05/19/2026——Sprinkler System
1 project · most recent 05/19/2026
Storm Water/Sanitary
FiledStatusContractorScope
05/19/2026——Storm, Water/Sanitary
1 project · most recent 05/19/2026
Steel Masonry
FiledStatusContractorScope
05/19/2026——Steel, Masonry
▾Special Inspection Requirements (DOB NOW) — 47
DateRequirementInspectorRole
03/12/2026Post-installed Anchors—special
03/02/2026Structural Steel - Welding—special
03/02/2026Post-installed anchors in masonry—special
03/02/2026Structural Steel - High Strength Bolting—special
03/02/2026Concrete - Precast—special
03/02/2026Concrete – Prestressed—special
03/02/2026Masonry—special
03/02/2026Structural Steel - Details—special
01/15/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
01/15/2026Fire-Resistant Penetrations and Joints—special
01/15/2026Post-installed Anchors—special
01/15/2026Fire-Resistant Penetrations and Joints—special
01/15/2026Shutoff dampers—energy_progress
01/15/2026Maintenance information—energy_progress
01/15/2026HVAC-R and service water piping design and insulation—energy_progress
01/15/2026HVAC-R and service water heating equipment—energy_progress
01/15/2026Electrical motors and elevators—energy_progress
01/15/2026HVAC-R and service water heating system controls—energy_progress
01/15/2026Duct leakage testing, insulation and design—energy_progress
01/15/2026Energy Code Compliance Inspections—progress
01/15/2026Post-installed Anchors—special
01/15/2026Fire-Resistant Penetrations and Joints—special
01/15/2026Exhaust and Vent Systems in Plenums and Ducts—special
01/15/2026HVAC-R and service water piping design and insulation—energy_progress
01/15/2026HVAC-R and service water heating system controls—energy_progress
Latest 25 of 47.
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/17/2026B01330190-S8Request digital key ↗
08/15/2026B01330190-S2Request digital key ↗
08/15/2026B01330190-S3Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026B01330190-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026B01330190-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/17/2026B01330190-S8Open ↗
08/17/2026B01330190-S6Open ↗
08/17/2026B01330190-S5Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026B01330190-I1Open ↗
▸Approvals, Objections & Sign-offs8
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
08/17/2026B01330190-S8Open ↗
08/17/2026B01330190-S7Open ↗
08/15/2026B01330190-S2Open ↗
Showing 3 of 8 on file for this type
▸Other Documents3
▸DOB NOWProperty Ownership Certification1
08/15/2026B01330190-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026B01330190-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026B01330190-I1Open ↗