← Back
Three families
1138 DECATUR STREET
BROOKLYN · Bushwick (East) · BIN 3079708
💬 Discuss this project
1899Year Built
2Stories
C0Building Class
R6Zoning
2,250 sfGross Floor Area
3Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Three families · 1,667 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
General
Cellar1p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/17/2023$1.8M—— → —$800/sf building
03/31/2022$890K—— → —$396/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HSU & ASSOCIATES108/18/2022
L & C ASSOCIATES108/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILD TEAM203/21/2026
L&C ASSOCIATES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUPERIOR PLUMBING & HEATINGPlumbing207/08/2026
MORELL BUILDERS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781108/18/2022
Building Lifecycle
All (17)Filed (2)Permit Issued (3)Signed Off (2)Violation (3)Inspection (7)
11/24/2025
Violation issued (HPD, open)
I
12/03/2024
Violation issued (HPD, open)
I
11/28/2023
Violation issued (HPD, open)
I
05/01/2023
Signed off — Alteration
B00744835-I1
04/29/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/24/2023
Signed off — Alteration
B00744909-I1
04/20/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/17/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/10/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/05/2023
Permit issued — Plumbing
B00744909-I1-PL
09/16/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/08/2022
Permit issued — Plumbing
B00744909-I1-PL
08/24/2022
Permit issued — General Construction
B00744835-I1-GC
08/18/2022
Filed — Alteration
B00744835-I1
08/18/2022
Filed — Alteration
B00744909-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI04/05/2023
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI09/08/2022
DOB NOWGeneral ConstructionSigned-offMORELL BUILDERS INC08/24/2022
1 project · most recent 05/09/2023
General Wiring
FiledStatusContractorScope
05/09/2023CompleteROYAL ELEC'L CONTR'G CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/29/2023Pass-Final General Construction Non-Directive 14PassView ↗
04/20/2023Fail-Final General Construction Non-Directive 14FailView ↗
04/17/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/10/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B00744835-I1Request digital key ↗
08/28/2026B00744909-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026B00744909-I1Open ↗
08/13/2026B00744835-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/28/2026B00744909-I1Open ↗
08/13/2026B00744835-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00744909-I1Open ↗
08/13/2026B00744835-I1Open ↗