← Back
Two family converted from one family
114-01 130 STREET
QUEENS · BIN 4251703
💬 Discuss this project
1925Year Built
2.5Stories
B3Building Class
R3-2Zoning
1,248 sfGross Floor Area
2Units
5 Open Violations 2 unresolved · 3 paperwork only ▸FDNY Report ↗
Two family converted from one family · 2,039 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
Roof1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KAIETEUR CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/31/2025$600K—— → —$481/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TABRIZ DESIGN GROUP205/01/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAIETEUR CONSTRUCTION INC.General Contractor104/09/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TABRIZ GROUP ENTERPRISES3275205/01/2025
Building Lifecycle
All (24)Filed (2)Permit Issued (2)Signed Off (2)Violation (13)Inspection (4)Special Inspection (1)
02/12/2026
Signed off — Alteration
APPLICATION FILE TO ADDRESS VIOLATION # 39111429H AND LISTED VIOLATIONS ON PLANS. AND PROPOSED INTERIOR AND EXTERIOR RENOVATION TO REPAIR LIMITED FIRE DAMAGE. EXISTING TWO FAMILY REMAINING.
Q01214481-I1
12/29/2025
Signed off — Alteration
REMOVE AND CAP ILLEGAL BATHROOM IN CELLAR, REMOVE AND CAP EXIST. BOILER AND HWH ANDASSOCIATED PLUMBING LINES. INSTALL TWO FIXTURE TOILET IN CELLAR. INSTALL 2 NEW NAVIEN COMBI. UNITS IN CELLAR. RELOCATE FIRST AND SECOND FLOORS KITCHEN SINKS AND STOVES.
Q01219038-I1
11/14/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/11/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/10/2025
Permit issued — Plumbing
Q01219038-I1-PL
06/04/2025
Violation issued (ECB, closed)
Construction
05/29/2025
Permit issued — General Construction
Q01214481-I1-GC
05/01/2025
Filed — Alteration
APPLICATION FILE TO ADDRESS VIOLATION # 39111429H AND LISTED VIOLATIONS ON PLANS. AND PROPOSED INTERIOR AND EXTERIOR RENOVATION TO REPAIR LIMITED FIRE DAMAGE. EXISTING TWO FAMILY REMAINING.
Q01214481-I1
05/01/2025
Filed — Alteration
REMOVE AND CAP ILLEGAL BATHROOM IN CELLAR, REMOVE AND CAP EXIST. BOILER AND HWH ANDASSOCIATED PLUMBING LINES. INSTALL TWO FIXTURE TOILET IN CELLAR. INSTALL 2 NEW NAVIEN COMBI. UNITS IN CELLAR. RELOCATE FIRST AND SECOND FLOORS KITCHEN SINKS AND STOVES.
Q01219038-I1
05/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
BAKHTIAR SHAMLOO
04/11/2024
Violation issued (ECB, closed)
Construction
10/15/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/13/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/09/2011
Violation issued (ECB, open)
Construction
06/24/2011
Violation issued (ECB, closed)
Construction
04/11/2011
Violation issued (ECB, closed)
Construction
03/09/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/23/2011
Violation issued (ECB, closed)
Construction
01/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2010
Violation issued (ECB, closed)
Construction
10/14/2010
Violation issued (ECB, open)
Construction
10/14/2010
Violation issued (ECB, open)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR07/10/2025
DOB NOWGeneral ConstructionSigned-offKAIETEUR CONSTRUCTION INC05/29/2025
1 project · most recent 12/09/2025
General Wiring
FiledStatusContractorScope
12/09/2025CompleteAYYUB ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/14/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
05/01/2025Fire-Resistant Penetrations and JointsBAKHTIAR SHAMLOOspecial
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01214481-I1Request digital key ↗
08/20/2026Q01219038-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01219038-I1Open ↗
08/13/2026Q01214481-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q01219038-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01219038-I1Open ↗
08/13/2026Q01214481-I1Open ↗