Four families
114 1 PLACE
BROOKLYN · BIN 3007786
💬 Discuss this project
1920Year Built
3Stories
C3Building Class
R6BZoning
4,273 sfGross Floor Area
4Units
Rent Stabilized0 Open Violations
Four families · Owner of record: ANSTAT REALTY LLC · 2,000 sf lot · 2.14 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof3p · 2 filings · 11 docs
Cellar5p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
A D GENERAL CONTRACTORS607/08/2026
ANSTAT1007/08/2026
ANSTAT REALTY LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/29/2021$3.8M—FIRST PLACE CAPITAL, LLC → ANSTAT REALTY LLC$878/sf building
09/29/2021$3.8M—FIRST PLACE CAPITAL, LLC → ANSTAT REALTY LLC$878/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FL&M ENGINEERING DESIGN &INSPECTION104/25/2022
KELLEY DESIGN202/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PROGENY MANAGEMENT & EXPEDITING SER403/21/2026
GREEN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & D GENERAL CONTR INCGeneral Contractor407/08/2026
GAUDIOSO CONTRACTING INCGeneral Contractor307/08/2026
FINE MECHANICAL CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KATZ, P.E.6087111/12/2021
Building Lifecycle
All (12)Filed (3)Permit Issued (5)Signed Off (2)Violation (2)
03/24/2023
Signed off — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS, ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE NYC CODE 2014, NO CHANGES IN USE EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00723368-I1
02/21/2023
Signed off — Alteration
RELOCATE 2 BATHROOMS, 1 KITCHEN, 1 WASHING MACHINE, AND 1 HW HEATER PER APARTMENT X 4 APARTMENTS. NO CHANGE OF USE EGRESS OR OCCUPANCY.
B00629631-I1
05/18/2022
Permit issued — General Construction
B00613015-I1-GC
04/25/2022
Filed — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS, ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE NYC CODE 2014, NO CHANGES IN USE EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00723368-I1
04/25/2022
Permit issued — Sidewalk Shed
B00723368-I1-SH
04/25/2022
Permit issued — Sidewalk Shed
B00723368-I1-SF
02/23/2022
Permit issued — Plumbing
B00629631-I1-PL
02/18/2022
Filed — Alteration
RELOCATE 2 BATHROOMS, 1 KITCHEN, 1 WASHING MACHINE, AND 1 HW HEATER PER APARTMENT X 4 APARTMENTS. NO CHANGE OF USE EGRESS OR OCCUPANCY.
B00629631-I1
02/18/2022
Violation issued (HPD, closed)
A
11/17/2021
Permit issued — General Construction
B00613015-I1-GC
11/12/2021
Filed — Alteration
B00613015-I1
04/05/2021
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offGAUDIOSO CONTRACTING05/18/2022
DOB NOWSidewalk ShedSigned-offA & D GENERAL CONTR INC04/25/2022
DOB NOWSidewalk ShedSigned-offA & D GENERAL CONTR INC04/25/2022
DOB NOWPlumbingSigned-offFINE MECHANICAL CORP02/23/2022
DOB NOWGeneral ConstructionSigned-offGAUDIOSO CONTRACTING11/17/2021
2 projects · most recent 07/19/2022
General Wiring HVAC Wiring
FiledStatusContractorScope
07/19/2022Permit IssuedSUNBIRD ELECTRICAL CONTRGeneral Wiring, HVAC Wiring
04/26/2022Permit IssuedHIGH QUALITY ELECTRIC OF—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
12/20/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/19/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/12/2021Structural Stability – Alterations of existing buildingsDavid Katzspecial
10/15/2021Fire-Resistant Penetrations and JointsDavid Katzspecial
10/15/2021FinalBeth Kelleyprogress
10/15/2021Fenestration and door U-factor and product ratingsBeth Kelleyenergy_progress
10/15/2021Air barrier - visual inspectionBeth Kelleyenergy_progress
10/15/2021Interior lighting powerBeth Kelleyenergy_progress
10/15/2021Lighting in dwelling unitsBeth Kelleyenergy_progress
10/15/2021Fenestration air leakageBeth Kelleyenergy_progress
10/15/2021Lighting controlsBeth Kelleyenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026B00613015-I1Request digital key ↗
08/31/2026B00629631-I1Request digital key ↗
08/29/2026B00723368-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00613015-I1Open ↗
08/29/2026B00723368-I1Open ↗
08/13/2026B00629631-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/22/2026B00613015-I1Open ↗
08/22/2026B00613015-I1Open ↗
08/22/2026B00613015-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00613015-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/31/2026B00613015-I1Open ↗
08/13/2026B00629631-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/31/2026B00613015-I1Open ↗