← Back
Two stories - detached, small or mid-size
114-17 128 STREET
QUEENS · South Ozone Park · BIN 4251699
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R3-2Zoning
1,344 sfGross Floor Area
1Units
9 Open Violations 8 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 2,494 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectrical
Roof3p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/28/2017$564K—— → —$420/sf building
04/27/2017$271K—Private party → 7625 HOLDINGS LLC$201/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC108/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SOLAR PRO INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244108/08/2025
Building Lifecycle
All (22)Filed (1)Permit Issued (1)Violation (9)Objection (6)Special Inspection (5)
11/25/2025
Violation issued (HPD, open)
I
09/05/2025
Permit issued — Solar
Q01268728-I1-SL
08/22/2025
Objection resolved — Addressed
08/22/2025
Objection resolved — Addressed
08/22/2025
Objection resolved — Addressed
08/19/2025
Objection raised — Electrical
08/19/2025
Objection raised — Zoning
08/19/2025
Objection raised — Structural
08/08/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01268728-I1
08/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
08/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
08/08/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
08/08/2025
Special inspection requirement — Final
NARESH MAHANGU
08/08/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
12/05/2024
Violation issued (HPD, open)
I
11/29/2023
Violation issued (HPD, open)
I
11/18/2022
Violation issued (HPD, open)
I
03/17/2022
Violation issued (HPD, open)
I
04/22/2021
Violation issued (HPD, open)
I
09/10/2020
Violation issued (ECB, open)
Construction
11/08/2019
Violation issued (HPD, open)
I
01/11/2018
Violation issued (HPD, open)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSOLAR PRO INC09/05/2025
2 projects · most recent 07/28/2025
FiledStatusContractorScope
07/28/2025Permit IssuedFLOW STATE ELECTRIC, LLC1 meters, 1 new_meters
07/09/2025Permit IssuedFLOW STATE ELECTRIC, LLC—
1 project · most recent 08/08/2025
FiledStatusContractorScope
08/08/2025Permit IssuedSOLAR PRO INC5 panels, 2.9 kw, 510 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/08/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
08/08/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
08/08/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
08/08/2025FinalNARESH MAHANGUprogress
08/08/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01268728-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026Q01268728-I1Open ↗
08/24/2026Q01268728-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026Q01268728-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q01268728-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01268728-I1Open ↗