← Back
Two stories - detached, small or mid-size
114-35 149 STREET
QUEENS · Baisley Park · BIN 4259592
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3AZoning
1,273 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,400 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
Electrical
Roof3p · 1 filing · 13 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR211/18/2025
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281211/18/2025
Building Lifecycle
All (12)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (8)
11/21/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 9 MODULES, 3.87KW
Q01224156-I1
11/18/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 9 MODULES, 3.87KW
Q01224156-P1
11/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
11/18/2025
Special inspection requirement — Final
Mina Makar
11/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
11/18/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
11/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
11/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
11/18/2025
Special inspection requirement — Final
Mina Makar
11/18/2025
Special inspection requirement — Air barrier - visual inspection
Mina Makar
05/14/2025
Permit issued — Solar
Q01224156-I1-SL
05/12/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS, ROOFTOP, RAILED, GRID-TIED, 9 MODULES, 3.87KW
Q01224156-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR05/14/2025
1 project · most recent 06/04/2025
FiledStatusContractorScope
06/04/2025CompleteISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
11/18/2025Fire-Resistant Penetrations and JointsMina Makarspecial
11/18/2025FinalMina Makarprogress
11/18/2025Energy Code Compliance InspectionsMina Makarprogress
11/18/2025Air barrier - visual inspectionMina Makarenergy_progress
11/18/2025Fire-Resistant Penetrations and JointsMina Makarspecial
11/18/2025Energy Code Compliance InspectionsMina Makarprogress
11/18/2025FinalMina Makarprogress
11/18/2025Air barrier - visual inspectionMina Makarenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01224156-I1Request digital key ↗
08/20/2026Q01224156-P1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026Q01224156-I1Open ↗
08/31/2026Q01224156-I1Open ↗
08/25/2026Q01224156-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01224156-P1Open ↗
08/20/2026Q01224156-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026Q01224156-I1Open ↗
08/25/2026Q01224156-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01224156-P1Open ↗
08/20/2026Q01224156-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01224156-I1Open ↗