← Back
Two stories - detached, small or mid-size
114-40 221 STREET
QUEENS · BIN 4242745
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R2AZoning
1,561 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,246 sf lot · 0.37 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
901 GREEN AVENUE BUILDERS103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/14/2020$402K—— → —$258/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PROFESSIONAL ENGINEERING SERVICE609/04/2025
RYAN HUNG ARCHITECT104/19/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NH EXPEDITING AND CONSULTING LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
901 GREEN AVENUE BUILDERSGeneral Contractor1007/08/2026
BENT MECHANICAL CORPPlumbing407/08/2026
Building Lifecycle
All (24)Filed (7)Permit Issued (8)Signed Off (1)Violation (2)Inspection (5)Special Inspection (1)
03/09/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/04/2025
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-P5
04/04/2025
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-P4
04/01/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/20/2025
Permit issued — Plumbing
Q00359888-I1-PL
03/18/2025
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-P3
03/14/2024
Permit issued — Plumbing
Q00359888-I1-PL
10/20/2022
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-P2
09/21/2022
Permit issued — Plumbing
Q00359888-I1-PL
09/19/2022
Signed off — Alteration
Q00505965-I1
05/02/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/02/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/18/2022
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-P1
01/21/2022
Permit issued — Construction Fence
Q00505965-I1-FN
10/01/2021
Permit issued — Construction Fence
Q00505965-I1-FN
08/23/2021
Permit issued — Construction Fence
Q00505965-I1-FN
08/04/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/30/2021
Violation issued (ECB, closed)
Construction
07/15/2021
Permit issued — Plumbing
Q00359888-I1-PL
04/20/2021
Permit issued — Construction Fence
Q00505965-I1-FN
04/19/2021
Filed — Alteration
Q00505965-I1
04/19/2021
Special inspection requirement — Final
RYAN HUNG
02/24/2021
Filed — Alteration
install 3 piece bathroom on second floor. install washer, dryer, and slop sink in cellar. legalize two piece bathroom in cellar.
Q00359888-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP03/20/2025
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP03/14/2024
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP09/21/2022
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS01/21/2022
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS10/01/2021
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS08/23/2021
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP07/15/2021
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS04/20/2021
BISOTISSUEDNYSS LLC11/17/2023
BIS—ISSUED901 GREEN AVENUE BUILDERS04/05/2022
BIS—ISSUED901 GREEN AVENUE BUILDERS11/10/2021
BIS—ISSUED901 GREEN AVENUE BUILDERS04/27/2021
1 project · most recent 09/04/2025
Gas Water/Sanitary
FiledStatusContractorScope
09/04/2025Signed-offBENT MECHANICAL CORPGas, Water/Sanitary
2 projects · most recent 08/17/2023
General Wiring
FiledStatusContractorScope
08/17/2023CompleteNY SOLAR ELECTRICAL LLC—
04/22/2021Permit IssuedTRIPLE D ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/09/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/01/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/02/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/02/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
04/19/2021FinalRYAN HUNGprogress
▾Documents — 90 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch - Plumbing6
08/25/2026Q00359888-P4Request digital key ↗
08/25/2026Q00359888-P3Request digital key ↗
08/25/2026Q00359888-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch1
08/27/2026Q00505965-I1Request digital key ↗
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION9
10/03/2024440799600Open ↗
03/01/2024440799600Open ↗
10/23/2023440799600Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION4
11/17/2023440799600Open ↗
05/24/2022440620712Open ↗
03/10/2022440620712Open ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISZONING DIAGRAM1
02/19/2021440620712Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/27/2026Q00505965-I1Open ↗
08/25/2026Q00359888-P1Open ↗
08/25/2026Q00359888-P4Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
10/23/2023440799600Open ↗
09/02/2020440620712Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/02/2020440620712Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026Q00505965-I1Open ↗
▸Safety & Tenant Protection9
▸DOB NOWTenant Protection Plan6
08/13/2026Q00359888-P2Open ↗
08/13/2026Q00359888-P3Open ↗
08/13/2026Q00359888-P4Open ↗
Showing 3 of 6 on file for this type
▸BISTPP1: TENANT PROTECTION PLAN2
11/17/2023440799600Open ↗
01/26/2021440620712Open ↗
▸BISSTREET TREE CHECKLIST1
09/02/2020440620712Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/25/2026Q00359888-P5Open ↗
08/25/2026Q00359888-P3Open ↗
08/25/2026Q00359888-P2Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/23/2023440799600Open ↗
09/02/2020440620712Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
02/29/2024440799600Open ↗
10/23/2023440799600Open ↗
09/02/2020440620712Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)2
10/21/2024440799600Open ↗
02/29/2024440799600Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/10/2024440799600Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
02/29/2024440799600Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/02/2020440620712Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
10/10/2024440799600Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
10/23/2023440799600Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY5
02/29/2024440799600Open ↗
11/17/2023440799600Open ↗
10/23/2023440799600Open ↗
Showing 3 of 5 on file for this type
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
10/10/2024440799600Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
10/10/2024440799600Open ↗
▸Approvals, Objections & Sign-offs10
▸BISSCHEDULE A - OCCUPANCY / USE3
01/22/2021440620712Open ↗
10/30/2020440620712Open ↗
09/02/2020440620712Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
03/07/2024440799600Open ↗
02/19/2021440620712Open ↗
▸BISFINAL1
10/10/2024440799600Open ↗
▸BISFINAL ELECTRICAL SIGNOFF1
03/07/2024440799600Open ↗
▸BISSUPERSEDING LETTER1
03/10/2022440620712Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/23/2024440799600Open ↗
▸BISPTA4: TAX ABATEMENT ELIGIBILITY APPROVAL1
10/10/2024440799600Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
10/23/2023440799600Open ↗
09/02/2020440620712Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
10/21/2024440799600Open ↗
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION5
10/18/2024440799600Open ↗
10/18/2024440799600Open ↗
03/07/2024440799600Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
10/23/2023440799600Open ↗
09/02/2020440620712Open ↗
▸BISBOROUGH INTAKE FORM2
05/24/2022440620712Open ↗
03/10/2022440620712Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM1
01/26/2021440620712Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
02/19/2021440620712Open ↗