← Back
Two family frame
1146 LELAND AVENUE
BRONX · Castle Hill-Unionport · BIN 2024439
💬 Discuss this project
1935Year Built
2Stories
B2Building Class
R5Zoning
1,792 sfGross Floor Area
2Units
43 Open Violations ▸FDNY Report ↗
Two family frame · 2,500 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 11p · 2 filings · 14 docs
Cellar2p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1227 WHITE PLAINS ROAD APT 236303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PENNAARCHITECT PC210/16/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACS ENVIRONMENTAL & CONSTGeneral Contractor303/21/2026
L.L.G. PLBG & HTG INCPlumbing307/08/2026
Building Lifecycle
All (79)Filed (2)Permit Issued (2)Signed Off (2)Violation (60)Inspection (5)Objection (4)Special Inspection (4)
11/24/2025
Violation issued (HPD, open)
I
12/03/2024
Violation issued (HPD, open)
I
11/28/2023
Violation issued (HPD, open)
I
11/17/2022
Violation issued (HPD, open)
I
08/22/2022
Violation issued (ECB, open)
Construction
08/05/2022
Signed off — Alteration
X00571625-I1
08/04/2022
Signed off — Alteration
X00613311-I1
08/04/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/01/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/16/2022
Violation issued (HPD, open)
I
03/02/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/21/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/19/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/27/2021
Violation issued (ECB, closed)
Construction
11/18/2021
Permit issued — Plumbing
X00613311-I1-PL
10/28/2021
Permit issued — General Construction
X00571625-I1-GC
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2021
Violation issued (ECB, open)
Construction
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/16/2021
Filed — Alteration
X00613311-I1
10/16/2021
Special inspection requirement — Energy Code Compliance Inspections
GIULIANO PENNA
10/16/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
GIULIANO PENNA
09/14/2021
Violation issued (ECB, closed)
Construction
09/14/2021
Violation issued (ECB, closed)
Construction
09/14/2021
Violation issued (ECB, closed)
Construction
08/16/2021
Objection raised — Other
08/16/2021
Objection resolved — Addressed
08/16/2021
Objection raised — Admin
08/16/2021
Objection resolved — Addressed
08/07/2021
Filed — Alteration
X00571625-I1
08/07/2021
Special inspection requirement — Energy Code Compliance Inspections
GIULIANO PENNA
08/07/2021
Special inspection requirement — Insulation placement and R values
GIULIANO PENNA
07/31/2021
Violation issued (ECB, closed)
Construction
07/29/2021
Violation issued (ECB, open)
Construction
07/29/2021
Violation issued (ECB, closed)
Construction
07/29/2021
Violation issued (ECB, open)
Construction
07/29/2021
Violation issued (ECB, closed)
Construction
04/21/2021
Violation issued (HPD, open)
I
11/07/2019
Violation issued (HPD, open)
I
10/22/2019
Violation issued (ECB, closed)
Construction
08/30/2019
Violation issued (ECB, closed)
Construction
08/30/2019
Violation issued (ECB, closed)
Construction
07/24/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/24/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/08/2019
Violation issued (ECB, closed)
Construction
07/02/2019
Violation issued (HPD, open)
C
05/23/2019
Violation issued (HPD, closed)
C
05/07/2019
Violation issued (HPD, open)
B
05/07/2019
Violation issued (HPD, open)
B
05/07/2019
Violation issued (HPD, open)
B
05/07/2019
Violation issued (HPD, open)
B
04/24/2019
Violation issued (ECB, closed)
Construction
04/24/2019
Violation issued (ECB, closed)
Construction
03/14/2019
Violation issued (HPD, open)
B
03/14/2019
Violation issued (HPD, closed)
C
03/14/2019
Violation issued (HPD, closed)
C
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offL.L.G. PLBG & HTG INC11/18/2021
DOB NOWGeneral ConstructionSigned-offACS ENVIRONMENTAL & CONST10/28/2021
BISPLISSUEDROCK E SMALL PLBG&HTG INC03/13/2019
BISOTISSUEDSMVP MGMT INC03/06/2019
BISOTISSUEDT. KAHN CONSTRUCTION INC.T/A/T/K10/14/1994
1 project · most recent 08/03/2021
FiledStatusContractorScope
08/03/2021CompleteADAM ELECL CONTRNG LLC—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/04/2022Pass-Final General Construction Non-Directive 14PassView ↗
07/01/2022Fail-Final General Construction Non-Directive 14FailView ↗
03/02/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/21/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/19/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
10/16/2021Energy Code Compliance InspectionsGIULIANO PENNAprogress
10/16/2021HVAC-R and service water piping design and insulationGIULIANO PENNAenergy_progress
08/07/2021Energy Code Compliance InspectionsGIULIANO PENNAprogress
08/07/2021Insulation placement and R valuesGIULIANO PENNAenergy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026X00613311-I1Request digital key ↗
08/15/2026X00571625-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
03/13/2019220687763Open ↗
03/06/2019220687763Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/04/2019220687763Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026X00613311-I1Open ↗
08/13/2026X00571625-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026X00613311-I1Open ↗
09/01/2026X00613311-I1Open ↗
08/27/2026X00571625-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00571625-I1Open ↗
08/25/2026X00613311-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/04/2019220687763Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/04/2019220687763Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/04/2019220687763Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
02/04/2019220687763Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
02/04/2019220687763Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026X00613311-I1Open ↗
08/15/2026X00571625-I1Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026X00571625-I1Open ↗
08/13/2026X00613311-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/04/2019220687763Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/04/2019220687763Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/04/2019220687763Open ↗