Four families
1146 ST MARKS AVENUE
BROOKLYN · BIN 3036023
💬 Discuss this project
1910Year Built
2Stories
C3Building Class
R6Zoning
3,200 sfGross Floor Area
4Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Four families · Owner of record: 1146 ST MARKS AVE, LLC · 3,130 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof13p · 1 filing · 20 docs
Floor 213p · 1 filing · 20 docs
Floor 113p · 1 filing · 20 docs
Cellar14p · 1 filing · 20 docs
1 job · most recent 03/20/2026
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/20/2026Permit IssuedNTF MANAGEMENT INCHeating Systems, Ventilation Systems
Heating
Vulcan LB-2500 1 kW · Electric Heater ×25
LB-3500 1 kW · Electric Heater ×12
LB-4500 1 kW ×2
Nvent Nuheat F1512 1 kW · Radiant ×4
F1212 1 kW · Radiant ×1
Ventilation
Panasonic FV-0511VF1 50 CFM · Exhaust Fan ×6
1 job · most recent 03/20/2026
Water/Sanitary
FiledStatusContractorScope
03/20/2026Permit IssuedP.S.I. MECHANICALWater/Sanitary
4 jobs · most recent 12/18/2025
General Wiring
FiledStatusContractorScope
12/18/2025CompleteKJK ELECTRIC INCGeneral Wiring
09/11/2025CompleteKJK ELECTRIC INC—
01/28/2022CompleteBERGER QUALITY ELEC'L CON1 meters
12/30/2021CompleteBERGER QUALITY ELEC'L CON—
1 job · most recent 03/20/2026
FiledStatusContractorScope
03/20/2026Permit IssuedP.S.I. MECHANICAL1 scope_items
Building Lifecycle
All (67)Filed (5)Permit Issued (3)Violation (29)Inspection (3)Special Inspection (27)
03/23/2026
Special inspection requirement — Mechanical Systems
Younes Abouyaala
03/23/2026
Special inspection requirement — Final
NAVEEN KUMAR
03/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
03/23/2026
Special inspection requirement — Ventilation and air distribution system
Younes Abouyaala
03/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
03/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
03/23/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
03/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
03/23/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
03/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
03/23/2026
Special inspection requirement — Final
NAVEEN KUMAR
03/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
03/23/2026
Special inspection requirement — Lighting controls
Younes Abouyaala
03/23/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
03/23/2026
Special inspection requirement — Lighting in dwelling units
Younes Abouyaala
03/23/2026
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
03/23/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
03/20/2026
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH FULL INTERIOR RENOVATION OF EXISTING 4-FAMILY RESIDENTIAL BUILDING. NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B01282290-P2
03/20/2026
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH FULL INTERIOR RENOVATION OF EXISTING 4-FAMILY RESIDENTIAL BUILDING. NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B01282290-P1
02/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
02/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
02/24/2026
Special inspection requirement — Final
NAVEEN KUMAR
02/24/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
02/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
02/24/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
02/24/2026
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
02/24/2026
Special inspection requirement — Lighting controls
Younes Abouyaala
02/24/2026
Special inspection requirement — Lighting in dwelling units
Younes Abouyaala
02/24/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
11/26/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/26/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/22/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/11/2025
Permit issued — Plumbing
B01282290-S2-PL
09/10/2025
Permit issued — Mechanical Systems
B01282290-S1-MS
09/10/2025
Permit issued — General Construction
B01282290-I1-GC
09/08/2025
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH FULL INTERIOR RENOVATION OF EXISTING 4-FAMILY RESIDENTIAL BUILDING. NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B01282290-S2
09/08/2025
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH FULL INTERIOR RENOVATION OF EXISTING 4-FAMILY RESIDENTIAL BUILDING. NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B01282290-S1
09/05/2025
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH FULL INTERIOR RENOVATION OF EXISTING 4-FAMILY RESIDENTIAL BUILDING. NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B01282290-I1
06/10/2025
Violation issued (HPD, closed)
A
11/26/2024
Violation issued (HPD, closed)
I
04/11/2024
Violation issued (HPD, closed)
A
11/20/2023
Violation issued (HPD, closed)
I
03/24/2023
Violation issued (HPD, closed)
A
11/07/2022
Violation issued (HPD, closed)
I
03/02/2022
Violation issued (HPD, closed)
A
03/02/2022
Violation issued (HPD, closed)
I
04/13/2021
Violation issued (HPD, closed)
I
04/13/2021
Violation issued (HPD, closed)
A
10/31/2019
Violation issued (HPD, closed)
I
10/19/2018
Violation issued (HPD, closed)
I
11/29/2017
Violation issued (HPD, closed)
I
11/15/2016
Violation issued (HPD, closed)
I
01/03/2016
Violation issued (HPD, closed)
C
01/03/2016
Violation issued (HPD, closed)
B
01/03/2016
Violation issued (HPD, closed)
B
01/03/2016
Violation issued (HPD, closed)
B
01/03/2016
Violation issued (HPD, closed)
C
01/03/2016
Violation issued (HPD, closed)
B
12/04/2015
Violation issued (HPD, closed)
B
12/04/2015
Violation issued (HPD, closed)
B
Latest 60 of 67 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GREENBROOK PARTNERS707/08/2026
1146 ST MARKS AVE, LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/15/2025$1.6M—— → —$500/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COMMERCIAL CONSTRUCTION CONSULTING303/20/2026
RIMKUS NEW YORK PLLC203/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EAST COAST EXPEDITING303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NTF MANAGEMENT INCGeneral Contractor204/09/2026
BERGER QUALITY ELEC'L CONElectrical103/22/2026
KJK ELECTRIC INCElectrical103/22/2026
P.S.I. MECHANICALPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519403/20/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedP.S.I. MECHANICAL09/11/2025
DOB NOWMechanical SystemsPermit IssuedNTF MANAGEMENT INC09/10/2025
DOB NOWGeneral ConstructionPermit IssuedNTF MANAGEMENT INC09/10/2025
BISOTISSUEDCENTURION SOLAR ENERGY11/24/2021
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/26/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/26/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/22/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
03/23/2026Mechanical SystemsYounes Abouyaalaspecial
03/23/2026FinalNAVEEN KUMARprogress
03/23/2026HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
03/23/2026Ventilation and air distribution systemYounes Abouyaalaenergy_progress
03/23/2026HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
03/23/2026HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
03/23/2026Maintenance informationYounes Abouyaalaenergy_progress
03/23/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
03/23/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
03/23/2026Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
03/23/2026FinalNAVEEN KUMARprogress
03/23/2026Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
03/23/2026Lighting controlsYounes Abouyaalaenergy_progress
03/23/2026Fenestration areasYounes Abouyaalaenergy_progress
03/23/2026Lighting in dwelling unitsYounes Abouyaalaenergy_progress
03/23/2026Air barrier - visual inspectionYounes Abouyaalaenergy_progress
03/23/2026Fenestration air leakageYounes Abouyaalaenergy_progress
02/24/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
02/24/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
02/24/2026FinalNAVEEN KUMARprogress
02/24/2026Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
02/24/2026Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
02/24/2026Fenestration areasYounes Abouyaalaenergy_progress
02/24/2026Air barrier - visual inspectionYounes Abouyaalaenergy_progress
02/24/2026Lighting controlsYounes Abouyaalaenergy_progress
Latest 25 of 27.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/20/2026B01282290-S1Request digital key ↗
08/20/2026B01282290-P2Request digital key ↗
08/20/2026B01282290-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION6
04/04/2025340828493Open ↗
04/04/2025340828493Open ↗
02/18/2025340828493Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION1
11/24/2021340828493Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026B01282290-S1Open ↗
09/23/2026B01282290-S1Open ↗
09/02/2026B01282290-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/20/2026B01282290-S1Open ↗
08/20/2026B01282290-I1Open ↗
08/13/2026B01282290-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01282290-S1Open ↗
09/02/2026B01282290-P1Open ↗
08/23/2026B01282290-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/18/2021340828493Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
11/24/2021340828493Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/20/2026B01282290-S1Open ↗
08/20/2026B01282290-I1Open ↗
08/13/2026B01282290-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/19/2021340828493Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/18/2021340828493Open ↗
11/18/2021340828493Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
11/18/2021340828493Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
11/19/2021340828493Open ↗
11/18/2021340828493Open ↗
11/18/2021340828493Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
11/18/2021340828493Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/18/2021340828493Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/19/2021340828493Open ↗