← Back
One story retail building
115-02 MERRICK BOULEVARD
QUEENS · BIN 4267371
💬 Discuss this project
1968Year Built
1Stories
K1Building Class
R6AZoning
14,000 sfGross Floor Area
3Units
One story retail building · Owner of record: 115 MER LLC · 45,800 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof1p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar6p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DANIEL GROUP3107/08/2026
TERLIS REALTY103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEE ENGINEERING, P.C.608/28/2024
LEON SKVIRSKY PE409/04/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEE ENGINEERING P C1203/21/2026
BUILDING BROTHERS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACTIVE SIGNSScaffold407/08/2026
YS NY CONSTRUCTION INCGeneral Contractor303/21/2026
C.R.U. MECHAN & HEATIN INFire Protection107/08/2026
C.R.U. MECHAN & HEAT INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LEE ENGINEERING, P.C.2157608/28/2024
Building Lifecycle
All (55)Filed (10)Permit Issued (7)Signed Off (7)Inspection (6)Special Inspection (25)
06/02/2025
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
05/28/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/28/2025
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
10/17/2024
Signed off — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-S1
10/07/2024
Signed off — Alteration
MODIFICATION OF SPRINKLER SYSTEM IN CELLAR. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q01047711-I1
10/04/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/28/2024
Signed off — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-I1
08/28/2024
Filed — Alteration
MODIFICATION OF SPRINKLER SYSTEM IN CELLAR. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q01047711-P1
08/28/2024
Special inspection requirement — Sprinkler Systems
YEON LEE
08/28/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
08/27/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
08/27/2024
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
08/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
08/27/2024
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
08/27/2024
Special inspection requirement — Mechanical Systems
YEON LEE
08/27/2024
Special inspection requirement — Final
YEON LEE
08/27/2024
Special inspection requirement — Maintenance information
YEON LEE
08/27/2024
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
08/26/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
08/26/2024
Special inspection requirement — Maintenance information
YEON LEE
08/26/2024
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
08/26/2024
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
08/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
08/26/2024
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
08/23/2024
Filed — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-P3
08/21/2024
Filed — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-P2
07/17/2024
Special inspection requirement — Maintenance information
YEON LEE
07/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
YEON LEE
07/17/2024
Special inspection requirement — Energy Code Compliance Inspections
YEON LEE
07/17/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
YEON LEE
07/17/2024
Special inspection requirement — HVAC-R and service water heating equipment
YEON LEE
07/17/2024
Special inspection requirement — HVAC-R and service water heating system controls
YEON LEE
06/26/2024
Permit issued — Sprinklers
Q01047711-I1-EW-SP
06/21/2024
Filed — Alteration
MODIFICATION OF SPRINKLER SYSTEM IN CELLAR. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
Q01047711-I1
05/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/16/2024
Permit issued — Plumbing
Q01014949-S1-PL
04/10/2024
Filed — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-S1
03/26/2024
Permit issued — Mechanical Systems
Q01014949-I1-GC-CX
03/20/2024
Filed — Alteration
Renovation of a Supermarket. (MECHANICAL WORK & GENERAL CONSTRUCTION WORK)
Q01014949-I1
01/19/2021
Signed off — Alteration
INSTALL NON ILLUMINATED WALL SIGN (PHARMACY)
Q00386391-I1
01/19/2021
Signed off — Alteration
RE-FACE EXISTING NON-ILLUMINATED D/F GROUND SIGN ((LOGO) RITE AID PHARMACY)
Q00386387-I1
01/19/2021
Signed off — Alteration
INSTALL ILLUMINATED WALL SIGN ((LOGO) RITE AID)
Q00386389-I1
01/19/2021
Signed off — Alteration
INSTALL ILLUMINATED WALL SIGN ((LOGO) RITE AID)
Q00386388-I1
11/02/2020
Permit issued — Sign
Q00386387-I1-SG
10/22/2020
Permit issued — Sign
Q00386391-I1-SG
10/22/2020
Permit issued — Sign
Q00386389-I1-SG
10/22/2020
Permit issued — Sign
Q00386388-I1-SG
09/04/2020
Filed — Alteration
INSTALL NON ILLUMINATED WALL SIGN (PHARMACY)
Q00386391-I1
09/04/2020
Filed — Alteration
RE-FACE EXISTING NON-ILLUMINATED D/F GROUND SIGN ((LOGO) RITE AID PHARMACY)
Q00386387-I1
09/04/2020
Filed — Alteration
INSTALL ILLUMINATED WALL SIGN ((LOGO) RITE AID)
Q00386389-I1
09/04/2020
Filed — Alteration
INSTALL ILLUMINATED WALL SIGN ((LOGO) RITE AID)
Q00386388-I1
09/04/2020
Special inspection requirement — Final
LEON SKVIRSKY
09/04/2020
Special inspection requirement — Final
LEON SKVIRSKY
09/04/2020
Special inspection requirement — Final
LEON SKVIRSKY
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offC.R.U. MECHAN & HEATIN IN06/26/2024
DOB NOWPlumbingSigned-offC.R.U. MECHAN & HEAT INC04/16/2024
DOB NOWMechanical SystemsSigned-offYS NY CONSTRUCTION INC03/26/2024
DOB NOWSignSigned-offACTIVE SIGNS INC11/02/2020
DOB NOWSignSigned-offACTIVE SIGNS INC10/22/2020
DOB NOWSignSigned-offACTIVE SIGNS INC10/22/2020
DOB NOWSignSigned-offACTIVE SIGNS INC10/22/2020
BISOTISSUEDCONCEPT AIR CONDITIONING10/05/2012
BISPLISSUEDTT MECHANICAL CORP09/30/2011
BISOTISSUEDA&F COMMERCIAL BUILDERS*09/27/2011
BISMHISSUEDA&F COMMERCIAL BUILDERS*09/27/2011
BISMHISSUEDARISTA AIR CONDITION CORP.04/22/1991
3 projects · most recent 05/22/2025
General Wiring
FiledStatusContractorScope
05/22/2025CompleteASKO ELEC CONST & MAIN INGeneral Wiring
09/03/2020CompleteRAINBOW ELECTRIC CO., INC—
09/03/2020CompleteRAINBOW ELECTRIC CO., INC—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/02/2025Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
05/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/28/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
10/04/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/23/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
08/28/2024Sprinkler SystemsYEON LEEspecial
08/28/2024Fire-Resistant Penetrations and JointsYEON LEEspecial
08/27/2024HVAC-R and service water piping design and insulationYEON LEEenergy_progress
08/27/2024HVAC-R and service water heating equipmentYEON LEEenergy_progress
08/27/2024Fire-Resistant Penetrations and JointsYEON LEEspecial
08/27/2024Energy Code Compliance InspectionsYEON LEEprogress
08/27/2024Mechanical SystemsYEON LEEspecial
08/27/2024FinalYEON LEEprogress
08/27/2024Maintenance informationYEON LEEenergy_progress
08/27/2024HVAC-R and service water heating system controlsYEON LEEenergy_progress
08/26/2024HVAC-R and service water piping design and insulationYEON LEEenergy_progress
08/26/2024Maintenance informationYEON LEEenergy_progress
08/26/2024HVAC-R and service water heating equipmentYEON LEEenergy_progress
08/26/2024Energy Code Compliance InspectionsYEON LEEprogress
08/26/2024Fire-Resistant Penetrations and JointsYEON LEEspecial
08/26/2024HVAC-R and service water heating system controlsYEON LEEenergy_progress
07/17/2024Maintenance informationYEON LEEenergy_progress
07/17/2024Fire-Resistant Penetrations and JointsYEON LEEspecial
07/17/2024Energy Code Compliance InspectionsYEON LEEprogress
07/17/2024HVAC-R and service water piping design and insulationYEON LEEenergy_progress
07/17/2024HVAC-R and service water heating equipmentYEON LEEenergy_progress
07/17/2024HVAC-R and service water heating system controlsYEON LEEenergy_progress
09/04/2020FinalLEON SKVIRSKYprogress
09/04/2020FinalLEON SKVIRSKYprogress
09/04/2020FinalLEON SKVIRSKYprogress
▾Documents — 105 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch6
08/21/2026Q01014949-I1Request digital key ↗
08/21/2026Q01014949-P3Request digital key ↗
08/21/2026Q01014949-P2Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Sign4
08/28/2026Q00386387-I1Request digital key ↗
08/28/2026Q00386391-I1Request digital key ↗
08/28/2026Q00386388-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
11/17/2012420481026Open ↗
12/05/2011420484924Open ↗
09/30/2011420484924Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION4
10/11/2012420481026Open ↗
10/03/2011420484924Open ↗
09/30/2011420484924Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications41
▸DOB NOWProgress Inspector Seal & Signature19
09/01/2026Q00386387-I1Open ↗
08/29/2026Q01014949-P3Open ↗
08/29/2026Q01014949-P3Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/28/2026Q00386387-I1Open ↗
08/21/2026Q01014949-I1Open ↗
08/21/2026Q01014949-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026Q01047711-I1Open ↗
08/29/2026Q01014949-P3Open ↗
08/29/2026Q01014949-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
10/03/2011420481026Open ↗
09/30/2011420484924Open ↗
09/30/2011420484924Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
09/30/2011420484924Open ↗
09/30/2011420484924Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/30/2011420484924Open ↗
▸Trade Schedules & Equipment7
▸BISSELF-CERT PLUMBING NOTICE3
01/06/2012420484924Open ↗
11/03/2011420484924Open ↗
10/20/2011420484924Open ↗
▸BISSCHEDULE B - PLUMBING2
12/05/2011420484924Open ↗
09/30/2011420484924Open ↗
▸BISEQUIPMENT USE PERMITS1
01/09/2013420481026Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
01/09/2013420481026Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
09/29/2011420481026Open ↗
▸Environmental & Asbestos18
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026Q01014949-S1Open ↗
08/21/2026Q01014949-I1Open ↗
08/13/2026Q01047711-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWOER: Notice of Satisfaction4
08/13/2026Q00386391-I1Open ↗
08/13/2026Q00386387-I1Open ↗
08/13/2026Q00386388-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWOER: Notice to Proceed4
08/13/2026Q00386391-I1Open ↗
08/13/2026Q00386389-I1Open ↗
08/13/2026Q00386387-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
10/11/2011420484924Open ↗
10/11/2011420484924Open ↗
09/29/2011420481026Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
10/13/2011420484924Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY3
09/30/2011420484924Open ↗
09/30/2011420484924Open ↗
09/29/2011420481026Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
11/05/2012420481026Open ↗
01/19/2012420484924Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/05/2012420481026Open ↗
▸Approvals, Objections & Sign-offs7
▸BISLETTERS - SUPPORTING DOCUMENTATION3
11/16/2012420481026Open ↗
10/11/2012420481026Open ↗
09/30/2011420484924Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
09/30/2011420484924Open ↗
09/29/2011420481026Open ↗
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST2
01/13/2012420484924Open ↗
01/09/2013420481026Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
11/05/2012420481026Open ↗
01/13/2012420484924Open ↗
09/30/2011420484924Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
09/30/2011420484924Open ↗
09/30/2011420484924Open ↗