← Back
Three families
115-15 14 ROAD
QUEENS · BIN 4097972
💬 Discuss this project
1901Year Built
3Stories
C0Building Class
R4-1Zoning
2,626 sfGross Floor Area
3Units
Rent Stabilized9 Open Violations ▸
Three families · 2,500 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Cellar2p · 1 filing · 13 docs
1 job · most recent 07/31/2022
General Wiring
FiledStatusContractorScope
07/31/2022CompleteABSOLUTE ADVANCED ELEC INGeneral Wiring
Building Lifecycle
All (33)Filed (2)Permit Issued (1)Signed Off (1)Violation (18)Inspection (5)Special Inspection (6)
05/06/2026
Violation issued (HPD, open)
A
06/11/2025
Violation issued (HPD, closed)
A
04/12/2024
Violation issued (HPD, closed)
A
04/04/2023
Signed off — Alteration
INSTALL THREE BOILERS AND THREE HOT WATER HEATERS IN THE CELLAR. NO CHANGE THE USE, EGRESS OR OCCUPANCY.
Q00794187-I1
03/27/2023
Violation issued (HPD, closed)
A
03/08/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/07/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/18/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/15/2022
Violation issued (HPD, closed)
I
11/04/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/01/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/30/2022
Special inspection requirement — Energy Code Compliance Inspections
luis wong
09/30/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
luis wong
09/30/2022
Special inspection requirement — HVAC-R and service water heating equipment
luis wong
09/29/2022
Filed — Alteration
INSTALL THREE BOILERS AND THREE HOT WATER HEATERS IN THE CELLAR. NO CHANGE THE USE, EGRESS OR OCCUPANCY.
Q00794187-P1
09/27/2022
Special inspection requirement — Energy Code Compliance Inspections
luis wong
09/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
luis wong
09/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
luis wong
08/26/2022
Permit issued — Plumbing
Q00794187-I1-PL
08/23/2022
Filed — Alteration
INSTALL THREE BOILERS AND THREE HOT WATER HEATERS IN THE CELLAR. NO CHANGE THE USE, EGRESS OR OCCUPANCY.
Q00794187-I1
03/02/2022
Violation issued (HPD, closed)
A
04/14/2021
Violation issued (HPD, closed)
A
11/16/2016
Violation issued (HPD, closed)
I
10/14/2015
Violation issued (HPD, closed)
I
02/25/2015
Violation issued (HPD, closed)
I
09/21/1987
Violation issued (HPD, open)
B
09/29/1976
Violation issued (HPD, open)
A
09/29/1976
Violation issued (HPD, open)
B
09/29/1976
Violation issued (HPD, open)
A
09/29/1976
Violation issued (HPD, open)
B
09/29/1976
Violation issued (HPD, open)
B
09/29/1976
Violation issued (HPD, open)
A
09/29/1976
Violation issued (HPD, open)
A
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
115-15 14 RD607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/19/2025$125K—Private party → Private party$48/sf building
05/12/2022$750K—— → —$286/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LCW ENGINEERING, P.C.209/29/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MPS PLUMBING & HEATING INCPlumbing107/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMPS PLUMBING & HEATING IN08/26/2022
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/08/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/07/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/18/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/04/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/01/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/30/2022Energy Code Compliance Inspectionsluis wongprogress
09/30/2022HVAC-R and service water piping design and insulationluis wongenergy_progress
09/30/2022HVAC-R and service water heating equipmentluis wongenergy_progress
09/27/2022Energy Code Compliance Inspectionsluis wongprogress
09/27/2022HVAC-R and service water piping design and insulationluis wongenergy_progress
09/27/2022HVAC-R and service water heating equipmentluis wongenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026Q00794187-I1Request digital key ↗
08/25/2026Q00794187-P1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature6
08/28/2026Q00794187-I1Open ↗
08/28/2026Q00794187-I1Open ↗
08/28/2026Q00794187-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026Q00794187-P1Open ↗
08/25/2026Q00794187-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026Q00794187-P1Open ↗
08/25/2026Q00794187-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00794187-I1Open ↗