← Back
BuildNYC
Elevator apt, semi-fireproof with stores
115 WEST 190TH STREET
BRONX · BIN 2129742
💬 Discuss this project
2022Year Built
5Stories
D7Building Class
R6Zoning
26,633 sfGross Floor Area
38Units
LL97 CoveredRent Stabilized1 Active Violation ▸FDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: 115 West 190 St · 10,701 sf lot · 2.49 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofIsra Holdings49p · 3 filings · 20 docs
BulkheadIsra Holdings1p · 1 filing · 7 docs
PenthouseIsra Holdings53p · 3 filings · 20 docs
Floor 4Isra Holdings56p · 4 filings · 20 docs
Floor 3Isra Holdings74p · 4 filings · 20 docs
Floor 2Isra Holdings71p · 4 filings · 20 docs
Floor 1Isra Holdings99p · 5 filings · 20 docs
CellarIsra Holdings64p · 3 filings · 20 docs
Site & exteriorIsra Holdings94p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Isra Holdings3507/08/2026
115 West 190 St203/22/2026
LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/14/2022$1.9M—BEEKMAN ENTERPRISES LTD. → 115 WEST 190 ST LLC$69/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BMG Design Build510/14/2024
Automated Design Engineering506/21/2023
Paul Perdek, Prof. Engineering403/14/2023
Elevated Engineering NYC506/13/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMG Group USA903/21/2026
NYC Design File403/21/2026
AE Design Solution803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Precision Builders USAGeneral Contractor1607/08/2026
Precision Builders USAGeneral Contractor807/08/2026
Core Scaffold SystemsScaffold603/21/2026
MW ConstructionScaffold303/21/2026
Precision Builders USAScaffold303/21/2026
MW ConstructionGeneral Contractor303/21/2026
Village P & H NYFire Protection107/08/2026
TFK ElectricElectrical103/22/2026
Precision Builders USAScaffold107/08/2026
Infiniti Esc PlumbingPlumbing107/08/2026
Solas ElectricalElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Automated Design Consulta895306/21/2023
Engineering Consulting SE2050702/20/2023
Shahrish Shuvo Engineering8524209/29/2022
Building Lifecycle
All (171)Filed (17)Permit Issued (20)Signed Off (12)Violation (19)Inspection (11)Objection (62)Special Inspection (30)
02/05/2025
Signed off — Alteration CO
FILING TO UPDATE COFO WORDING TO INCLUDE "AMBULATORY DIAGNOSTIC TREATMENT HEALTH CARE FACILITY OR CHILDCARE OR AFTERSCHOOL CHILDCARE SERVICES UP TO 40 PEOPLE (COMMUNITY FACILITY)". NO CHANGE TO USE OR OCCUPANCY.
X01111955-I1
12/18/2024
Permit issued — General Construction
X01111955-I1-GC
12/11/2024
Objection resolved — Addressed
12/11/2024
Objection resolved — Addressed
11/27/2024
Objection raised — Energy
11/27/2024
Objection raised — Admin
11/27/2024
Objection resolved — Addressed
11/04/2024
Objection raised — Admin
10/14/2024
Filed — Alteration CO
FILING TO UPDATE COFO WORDING TO INCLUDE "AMBULATORY DIAGNOSTIC TREATMENT HEALTH CARE FACILITY OR CHILDCARE OR AFTERSCHOOL CHILDCARE SERVICES UP TO 40 PEOPLE (COMMUNITY FACILITY)". NO CHANGE TO USE OR OCCUPANCY.
X01111955-I1
09/27/2024
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-I1
05/02/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/16/2024
Signed off — Alteration
Install sprinkler and plumbing systems per the plans filed herewith and in conjunction with NB#X00681066. The sprinkler system is hydraulically calculated. There is no change in use, occupancy, or egress.
X08013091-I1
12/29/2023
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
12/06/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/28/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/15/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/14/2023
Signed off — Alteration
Install mechanical systems per the plans filed herewith and in conjunction with NB#X00681066. There is no change in use occupancy or egress.
X08013083-I1
11/14/2023
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-S7
11/13/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
10/24/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X08023943-I1
10/24/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X08041712-I1
10/24/2023
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
07/07/2023
Permit issued — Mechanical Systems
X08013083-I1-MS
07/04/2023
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-S4
06/21/2023
Filed — Alteration
Install sprinkler and plumbing systems per the plans filed herewith and in conjunction with NB#X00681066. The sprinkler system is hydraulically calculated. There is no change in use, occupancy, or egress.
X08013091-P1
06/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Gregory Mortman
06/21/2023
Special inspection requirement — Sprinkler Systems
Gregory Mortman
06/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
Gregory Mortman
06/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Gregory Mortman
06/21/2023
Special inspection requirement — Maintenance information
Gregory Mortman
06/21/2023
Special inspection requirement — HVAC-R and service water heating system controls
Gregory Mortman
05/27/2023
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-S3
05/26/2023
Permit issued — Support of Excavation
X00681066-S3-SE
05/24/2023
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-S1
05/23/2023
Signed off — New Building
Filing - CC application subsequent to primary application X00681066-I1
X00681066-S2
05/23/2023
Signed off — Alteration
Filing Foundation in conjunction to primary application X00681066-I1
X00744906-I1
05/22/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
05/22/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
PAUL MARINO
05/22/2023
Special inspection requirement — Fenestration areas
PAUL MARINO
05/22/2023
Special inspection requirement — Protection of exposed foundation insulation
PAUL MARINO
05/22/2023
Special inspection requirement — Maintenance information
PAUL MARINO
05/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
05/22/2023
Special inspection requirement — Lighting controls
PAUL MARINO
05/22/2023
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
05/22/2023
Special inspection requirement — Interior lighting power
PAUL MARINO
05/22/2023
Special inspection requirement — Fenestration air leakage
PAUL MARINO
05/22/2023
Special inspection requirement — Metering
PAUL MARINO
05/22/2023
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
05/22/2023
Special inspection requirement — Exterior lighting power
PAUL MARINO
05/22/2023
Special inspection requirement — Lighting in dwelling units
PAUL MARINO
05/22/2023
Special inspection requirement — Insulation placement and R values
PAUL MARINO
05/22/2023
Special inspection requirement — Air barrier — testing
PAUL MARINO
05/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
PAUL MARINO
05/22/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
05/18/2023
Objection resolved — Addressed
05/12/2023
Permit issued — Construction Fence
X00681066-S4-FN
05/12/2023
Permit issued — General Construction
X00681066-I1-GC
05/03/2023
Permit issued — Plumbing
X08013091-I1-EW-SP
05/01/2023
Violation issued (ECB, closed)
Construction
05/01/2023
Violation issued (ECB, closed)
Construction
Latest 60 of 171 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPrecision Build USA12/18/2024
DOB NOWMechanical SystemsSigned-offPrecision Build USA07/07/2023
DOB NOWSupport of ExcavationSigned-offPrecision Builders USA05/26/2023
DOB NOWConstruction FenceSigned-offPrecision Build USA05/12/2023
DOB NOWGeneral ConstructionPermit IssuedPrecision Build USA05/12/2023
DOB NOWSprinklersSigned-offVillage P & H NY05/03/2023
DOB NOWCurb CutSigned-offPrecision Build USA04/20/2023
DOB NOWGeneral ConstructionPermit IssuedMW Construction03/24/2023
DOB NOWConstruction FenceSigned-offMW Construction03/23/2023
DOB NOWStructuralSigned-offPrecision Builders USA01/24/2023
DOB NOWGeneral ConstructionPermit IssuedPrecision Builders USA01/23/2023
DOB NOWGeneral ConstructionPermit IssuedPrecision Builders USA11/22/2022
DOB NOWSupported ScaffoldSigned-offCore Scaffold Systems11/20/2022
DOB NOWStructuralSigned-offPrecision Builders USA10/25/2022
DOB NOWSidewalk ShedSigned-offCore Scaffold Systems10/21/2022
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing10/05/2022
DOB NOWFoundationSigned-offPrecision Builders USA08/09/2022
DOB NOWFoundationSigned-offPrecision Builders USA07/14/2022
DOB NOWFoundationSigned-offPrecision Builders USA06/03/2022
DOB NOWConstruction FenceSigned-offPrecision Builders USA03/25/2022
1 project · most recent 03/29/2023
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/29/2023Signed-offPrecision Builders USAHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Ice Air RSX09 9,200 BTU · Heat Pump Outdoor ×81
RSXC18 16,300 BTU · Heat Pump Outdoor ×3
Cadet CEC163TW 5,115 BTU · Electric Heater ×21
Ventilation
Broan 413001 with charcoal filter 150 CFM · Kitchen Exhaust ×37
Fantech REC6 160 CFM · Erv ×14
REC8 XL 320 CFM · Erv ×5
1 project · most recent 03/29/2023
Storm Water/Sanitary
FiledStatusContractorScope
03/29/2023——Storm, Water/Sanitary
5 projects · most recent 10/09/2024
General Wiring
FiledStatusContractorScope
10/09/2024CompleteTFK ElectricGeneral Wiring
10/02/2024Permit IssuedTFK Electric40 meters, 40 new_meters
11/15/2022CompleteSolas Electrical—
11/03/2022CompleteTFK Electric—
10/28/2022CompleteSolas Electrical—
1 project · most recent 03/29/2023
Concrete
FiledStatusContractorScope
03/29/2023Signed-offPrecision Builders USAConcrete
1 project · most recent 03/29/2023
Fence
FiledStatusContractorScope
03/29/2023Signed-offPrecision Builders USAFence
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
12/29/2023Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
12/06/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/28/2023Pass-Final CND-Occupancy InspectionPassView ↗
11/15/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/13/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
10/24/2023Fail-Final Curb Cut Non-Directive 14FailView ↗
03/31/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/31/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/07/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/12/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/12/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
06/21/2023Energy Code Compliance InspectionsGregory Mortmanprogress
06/21/2023HVAC-R and service water piping design and insulationGregory Mortmanenergy_progress
06/21/2023Maintenance informationGregory Mortmanenergy_progress
06/21/2023HVAC-R and service water heating system controlsGregory Mortmanenergy_progress
06/21/2023HVAC-R and service water heating equipmentGregory Mortmanenergy_progress
06/21/2023Sprinkler SystemsGregory Mortmanspecial
05/22/2023Fire-Resistant Penetrations and JointsPAUL MARINOspecial
05/22/2023Energy Code Compliance InspectionsPAUL MARINOprogress
05/22/2023Fire-Resistance Rated ConstructionPAUL MARINOprogress
05/22/2023Insulation placement and R valuesPAUL MARINOenergy_progress
05/22/2023Exterior lighting powerPAUL MARINOenergy_progress
05/22/2023Air barrier - visual inspectionPAUL MARINOenergy_progress
05/22/2023MeteringPAUL MARINOenergy_progress
05/22/2023Interior lighting powerPAUL MARINOenergy_progress
05/22/2023Lighting in dwelling unitsPAUL MARINOenergy_progress
05/22/2023Protection of exposed foundation insulationPAUL MARINOenergy_progress
05/22/2023Air barrier — testing PAUL MARINOenergy_progress
05/22/2023HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
05/22/2023Maintenance informationPAUL MARINOenergy_progress
05/22/2023Fenestration air leakagePAUL MARINOenergy_progress
05/22/2023Lighting controlsPAUL MARINOenergy_progress
05/22/2023Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
05/22/2023Fenestration areasPAUL MARINOenergy_progress
05/22/2023Exterior Insulation and Finish Systems (EIFS)PAUL MARINOspecial
09/29/2022HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
Latest 25 of 66.
▾Documents — 141 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
08/24/2026X00744906-P2Request digital key ↗
08/24/2026X00744906-I1Request digital key ↗
08/23/2026X08013083-I1Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION5
11/18/2022240317064Open ↗
11/10/2022240317064Open ↗
11/10/2022240317064Open ↗
Showing 3 of 5 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
12/09/2022240317064Open ↗
06/28/2022240317064Open ↗
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026X00681066-P1Open ↗
08/13/2026X01111955-I1Open ↗
08/13/2026X00681066-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026X00681066-I1Open ↗
08/13/2026X00681066-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026X01111955-I1Open ↗
08/13/2026X00681066-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/10/2022240317064Open ↗
▸Seals & Professional Certifications64
▸DOB NOWProgress Inspector Seal & Signature29
08/29/2026X00681066-S1Open ↗
08/29/2026X00681066-S1Open ↗
08/28/2026X00744906-P2Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature18
08/24/2026X00744906-I1Open ↗
08/23/2026X08013083-I1Open ↗
08/23/2026X00681066-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
08/29/2026X00681066-S1Open ↗
08/29/2026X00681066-S1Open ↗
08/29/2026X00681066-S1Open ↗
Showing 3 of 16 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
06/28/2022240317064Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026X00681066-P1Open ↗
08/13/2026X00681066-I1Open ↗
▸Safety & Tenant Protection12
▸DOB NOWStreet Tree Checklist3
08/13/2026X01111955-I1Open ↗
08/13/2026X00681066-I1Open ↗
08/13/2026X00681066-P1Open ↗
▸DOB NOWStreet Tree Sign Off2
08/13/2026X01111955-I1Open ↗
08/13/2026X00681066-I1Open ↗
▸DOB NOWStreet Trees Site Plan2
08/13/2026X00681066-I1Open ↗
08/13/2026X01111955-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
08/13/2026X00681066-I1Open ↗
08/13/2026X01111955-I1Open ↗
▸BISSTREET TREE CHECKLIST1
06/28/2022240317064Open ↗
▸BISSTREET TREE SIGNOFF1
11/09/2023240317064Open ↗
▸BISSTREET TREES SITE PLAN1
12/09/2022240317064Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026X00681066-I1Open ↗
▸Inspections & Test Reports10
▸DOB NOWSOIL REPORT4
08/24/2026X00744906-I1Open ↗
08/13/2026X00681066-S1Open ↗
08/13/2026X00681066-S3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram3
08/13/2026X00744906-I1Open ↗
08/13/2026X00681066-S1Open ↗
08/13/2026X00681066-S3Open ↗
▸DOB NOWTR4 Plot Diagram3
08/13/2026X00744906-I1Open ↗
08/13/2026X00681066-S3Open ↗
08/13/2026X00681066-S1Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION2
12/09/2022240317064Open ↗
11/10/2022240317064Open ↗
▸DOB NOWAI1 Form (from plan PDF)2
08/16/2026X08023943-P1Open ↗
08/16/2026X08041712-P1Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/28/2022240317064Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/28/2022240317064Open ↗
▸Other Documents12
▸DOB NOWProperty Ownership Certification3
08/23/2026X00681066-I1Open ↗
08/23/2026X00681066-P1Open ↗
08/20/2026X01111955-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026X00681066-I1Open ↗
08/13/2026X00681066-P1Open ↗
▸DOB NOWFinal Survey2
08/13/2026X01111955-I1Open ↗
08/13/2026X00681066-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026X00681066-I1Open ↗
08/13/2026X00681066-P1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
06/28/2022240317064Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026X00681066-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00681066-S3Open ↗