← Back
One family attached or semi-detached
1154 EAST 82 STREET
BROOKLYN · Canarsie · BIN 3226006
💬 Discuss this project
1965Year Built
2Stories
A5Building Class
R5Zoning
1,120 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
One family attached or semi-detached · 1,800 sf lot · 0.62 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalGeneral
Filed — no permit issued16p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/14/2015$297K—BUSHWICK HOMES LLC → Private party$265/sf building
02/11/2015$185K—Private party → BUSHWICK HOMES LLC$165/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC111/29/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802111/29/2023
Building Lifecycle
All (11)Filed (1)Violation (1)Objection (4)Special Inspection (5)
12/07/2023
Objection raised — Other
12/07/2023
Objection raised — Scope
12/07/2023
Objection raised — Mechanical
12/07/2023
Objection raised — Other
11/29/2023
Filed — Alteration
ROOFTOP SOILAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B00968944-I1
11/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
11/29/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
11/29/2023
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
11/29/2023
Special inspection requirement — Final
Kaijin Liang
11/29/2023
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
04/27/2017
Violation issued (ECB, open)
Construction
Nothing on file for this building.
1 project · most recent 11/18/2023
FiledStatusContractorScope
11/18/2023Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 11/29/2023
FiledStatusContractorScope
11/29/2023——10 panels, 4 kw, 526.85 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/29/2023Fire-Resistant Penetrations and JointsKaijin Liangspecial
11/29/2023Structural Stability – Alterations of existing buildingsKaijin Liangspecial
11/29/2023Energy Code Compliance InspectionsKaijin Liangprogress
11/29/2023FinalKaijin Liangprogress
11/29/2023Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 3 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B00968944-I1Request digital key ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/26/2026B00968944-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026B00968944-I1Open ↗