← Back
Two stories - detached, small or mid-size
1156 EAST 21 STREET
BROOKLYN · Midwood · BIN 3207486
💬 Discuss this project
1925Year Built
3Stories
A1Building Class
R2Zoning
4,309 sfGross Floor Area
1Units
2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 4,450 sf lot · 0.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingLandscapeGeneral
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 6 docs
AtticUnder Construction17p · 1 filing · 20 docs
Floor 2Under Construction26p · 1 filing · 20 docs
Floor 1Under Construction25p · 1 filing · 20 docs
CellarUnder Construction26p · 1 filing · 20 docs
Site & exteriorUnder Construction29p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/07/2018$1.2M—— → —$290/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AL FFRED ARCHITECTURE PLLC302/12/2026
ETRECTE LLC106/30/2025
RAHMAN CONSULTING312/07/2022
ALFRED MIERZEJEWSKI110/26/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARC DESIGN AND CONSULTING LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TFJ CONTRACTING LLCGeneral Contractor1707/08/2026
B&B MECH PLBG & HTG LLCPlumbing307/08/2026
AMBER ELECTL CONTNG INCElectrical103/22/2026
FICAZZOLA CONSULTING LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. INT'L ENGINEERING PLLC3129602/12/2026
JAMES A CLANCY9176106/30/2025
Building Lifecycle
All (75)Filed (8)Permit Issued (19)Signed Off (5)Violation (3)Inspection (10)Special Inspection (30)
06/03/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S1
05/11/2026
Permit issued — Plumbing
B00795804-S2-PL
04/30/2026
Violation issued (ECB, open)
Construction
04/30/2026
Violation issued (ECB, open)
Unknown
03/05/2026
Signed off — Alteration
Installation PV System on existing roof top. No changes to the use egress or occupancy.
B01247562-I1
02/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
02/24/2026
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
02/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
02/24/2026
Special inspection requirement — Permanent certificate
NANIK MASSAND
02/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
02/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
02/24/2026
Special inspection requirement — Maintenance information
NANIK MASSAND
02/12/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-P1
02/04/2026
Special inspection requirement — Permanent certificate
NANIK MASSAND
02/04/2026
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
02/04/2026
Special inspection requirement — Maintenance information
NANIK MASSAND
02/04/2026
Special inspection requirement — HVAC-R and service water heating equipment
NANIK MASSAND
02/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
NANIK MASSAND
02/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
NANIK MASSAND
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
01/14/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S3
01/14/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S5
01/13/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S4
12/11/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/10/2025
Inspection — Passed CND-Occupancy Inspection
Pass
View inspection ↗
11/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/13/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/13/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/04/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/29/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/01/2025
Permit issued — Solar
B01247562-I1-SL
06/30/2025
Filed — Alteration
Installation PV System on existing roof top. No changes to the use egress or occupancy.
B01247562-I1
06/26/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
James Clancy
06/26/2025
Special inspection requirement — Energy Code Compliance Inspections
James Clancy
06/26/2025
Special inspection requirement — Final
James Clancy
06/26/2025
Special inspection requirement — Air barrier - visual inspection
James Clancy
06/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
James Clancy
05/28/2025
Permit issued — Structural
B00795804-S3-ST
05/28/2025
Permit issued — Foundation
B00795804-S5-FO
05/28/2025
Permit issued — Construction Fence
B00795804-S1-FN
05/28/2025
Permit issued — Support of Excavation
B00795804-S4-SE
05/28/2025
Permit issued — General Construction
B00795804-I1-GC
05/12/2025
Permit issued — Plumbing
B00795804-S2-PL
01/16/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/30/2024
Permit issued — Support of Excavation
B00795804-S4-SE
05/30/2024
Permit issued — General Construction
B00795804-I1-GC
05/30/2024
Permit issued — Construction Fence
B00795804-S1-FN
05/30/2024
Permit issued — Foundation
B00795804-S5-FO
05/30/2024
Permit issued — Structural
B00795804-S3-ST
05/07/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
04/18/2024
Permit issued — Plumbing
B00795804-S2-PL
01/30/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S2
06/01/2023
Permit issued — Structural
B00795804-S3-ST
06/01/2023
Permit issued — General Construction
B00795804-I1-GC
06/01/2023
Permit issued — Foundation
B00795804-S5-FO
06/01/2023
Permit issued — Support of Excavation
B00795804-S4-SE
05/23/2023
Permit issued — Construction Fence
B00795804-S1-FN
12/07/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING WORK
B00795804-S5
Latest 60 of 75 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offB&B MECH PLBG & HTG LLC05/11/2026
DOB NOWSolarSigned-offFICAZZOLA CONSULTING07/01/2025
DOB NOWStructuralSigned-offTFJ CONTRACTING LLC05/28/2025
DOB NOWFoundationSigned-offTFJ CONTRACTING LLC05/28/2025
DOB NOWConstruction FenceSigned-offTFJ CONTRACTING LLC05/28/2025
DOB NOWSupport of ExcavationSigned-offTFJ CONTRACTING LLC05/28/2025
DOB NOWGeneral ConstructionPermit IssuedTFJ CONTRACTING LLC05/28/2025
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC05/12/2025
DOB NOWSupport of ExcavationSigned-offTFJ CONTRACTING LLC05/30/2024
DOB NOWGeneral ConstructionPermit IssuedTFJ CONTRACTING LLC05/30/2024
DOB NOWConstruction FenceSigned-offTFJ CONTRACTING LLC05/30/2024
DOB NOWFoundationSigned-offTFJ CONTRACTING LLC05/30/2024
DOB NOWStructuralSigned-offTFJ CONTRACTING LLC05/30/2024
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC04/18/2024
DOB NOWStructuralSigned-offTFJ CONTRACTING LLC06/01/2023
DOB NOWGeneral ConstructionPermit IssuedTFJ CONTRACTING LLC06/01/2023
DOB NOWFoundationSigned-offTFJ CONTRACTING LLC06/01/2023
DOB NOWSupport of ExcavationSigned-offTFJ CONTRACTING LLC06/01/2023
DOB NOWConstruction FenceSigned-offTFJ CONTRACTING LLC05/23/2023
1 project · most recent 02/12/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
02/12/2026Signed-offB&B MECH PLBG & HTG LLCGas, Storm, Water/Sanitary
3 projects · most recent 05/19/2026
General Wiring
FiledStatusContractorScope
05/19/2026CompleteFABCO ELECTRICAL CONT.INCGeneral Wiring
04/22/2025CompleteAMBER ELECTL CONTNG INC—
10/31/2024Permit IssuedJ & F ELECL CONTNG INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
11/10/2025Passed CND-Occupancy InspectionPassView ↗
11/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/13/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/13/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/04/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/29/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/16/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/07/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 57
DateRequirementInspectorRole
02/24/2026Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
02/24/2026Energy Code Compliance InspectionsNANIK MASSANDprogress
02/24/2026HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
02/24/2026Permanent certificateNANIK MASSANDenergy_progress
02/24/2026HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
02/24/2026HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
02/24/2026Maintenance informationNANIK MASSANDenergy_progress
02/04/2026Permanent certificateNANIK MASSANDenergy_progress
02/04/2026Energy Code Compliance InspectionsNANIK MASSANDprogress
02/04/2026Maintenance informationNANIK MASSANDenergy_progress
02/04/2026HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
02/04/2026HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
02/04/2026HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
02/04/2026Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
06/26/2025Structural Stability – Alterations of existing buildingsJames Clancyspecial
06/26/2025Energy Code Compliance InspectionsJames Clancyprogress
06/26/2025FinalJames Clancyprogress
06/26/2025Air barrier - visual inspectionJames Clancyenergy_progress
06/26/2025Fire-Resistant Penetrations and JointsJames Clancyspecial
12/05/2022Subgrade InspectionsNANIK MASSANDspecial
12/05/2022Construction Operations Influencing Adjacent StructuresNANIK MASSANDspecial
12/05/2022Concrete - Cast-In-PlaceNANIK MASSANDspecial
12/05/2022Structural Stability – Alterations of existing buildingsNANIK MASSANDspecial
12/05/2022Construction Operations Influencing Adjacent StructuresNANIK MASSANDspecial
12/05/2022Excavations - Sheeting, Shoring, and BracingNANIK MASSANDspecial
Latest 25 of 57.
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/28/2026B00795804-S5Request digital key ↗
08/28/2026B00795804-S4Request digital key ↗
08/28/2026B00795804-S3Request digital key ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00795804-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00795804-I1Open ↗
▸Seals & Professional Certifications29
▸DOB NOWProgress Inspector Seal & Signature12
09/02/2026B00795804-S5Open ↗
09/02/2026B00795804-S5Open ↗
09/01/2026B00795804-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/28/2026B00795804-S4Open ↗
09/28/2026B00795804-S4Open ↗
09/02/2026B00795804-S5Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/28/2026B00795804-S5Open ↗
08/28/2026B00795804-S4Open ↗
08/28/2026B00795804-S3Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/29/2022340865736Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026B00795804-I1Open ↗
▸Safety & Tenant Protection1
▸BISBPP: STREET TREES SITE PLAN1
11/29/2022340865736Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/28/2026B00795804-S2Open ↗
08/28/2026B00795804-S5Open ↗
08/28/2026B00795804-S4Open ↗
Showing 3 of 7 on file for this type
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00795804-S4Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B00795804-S4Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B00795804-S5Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01247562-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/29/2022340865736Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/28/2026B00795804-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00795804-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00795804-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00795804-S4Open ↗