← Back
Factory, industrial, semi-fireproof
116-02 15 AVENUE
QUEENS · BIN 4098227
💬 Discuss this project
1916Year Built
2Stories
F4Building Class
M2-1Zoning
224,500 sfGross Floor Area
7Units
LL97 Covered4 Open Violations 3 unresolved · 1 paperwork only ▸
Factory, industrial, semi-fireproof · Owner of record: CANADA DRY BOTTLING CO · 490,105 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
MechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction12p · 2 filings · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PEPSI BOTTELING CO2609/12/2026
CANADA DRY BOTTLING CO203/22/2026
NYCP903/21/2026
PEPSI BOTTELING CO. OF NY703/21/2026
PEPSI BOTTLING CO. OF NEW YORK203/21/2026
PEPSI COLA BOTTLING COMPANY403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAZINI ENGINEERING, P.C.406/03/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYNAIRE LLCGeneral Contractor308/13/2026
MCCREADY & RICE PLUMBINGPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAZINI ENGINEERING, P.C.1808206/03/2026
Building Lifecycle
All (34)Filed (4)Permit Issued (5)Violation (21)Inspection (1)Special Inspection (3)
08/19/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/12/2026
Permit issued — General Construction
Q01306770-I1-GC
06/15/2026
Permit issued — Plumbing
Q01402311-S1-PL
06/10/2026
Permit issued — Mechanical Systems
Q01402311-I1-GC-CX
06/03/2026
Filed — Alteration
INSTALLATION OF FIVE (5) REPLACEMENT ROOFTOP HVAC UNITS MOUNTED ON EXISTING SUPPORTS AND CONNECTED TO EXISTING DUCTWORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01402311-S1
06/03/2026
Filed — Alteration
INSTALLATION OF FIVE (5) REPLACEMENT ROOFTOP HVAC UNITS MOUNTED ON EXISTING SUPPORTS AND CONNECTED TO EXISTING DUCTWORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01402311-I1
12/03/2025
Permit issued — Plumbing
Q01306770-S1-PL
12/01/2025
Permit issued — General Construction
Q01306770-I1-MS
11/26/2025
Filed — Alteration
INSTALLATION OF SIX (6) REPLACEMENT ROOFTOP HVAC UNITS MOUNTED ON EXISTING SUPPORTS AND CONNECTED TO EXISTING DUCTWORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01306770-I1
11/26/2025
Filed — Alteration
INSTALLATION OF SIX (6) REPLACEMENT ROOFTOP HVAC UNITS MOUNTED ON EXISTING SUPPORTS AND CONNECTED TO EXISTING DUCTWORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01306770-S1
11/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
Joseph Bazini
10/22/2025
Special inspection requirement — Mechanical Systems
Joseph Bazini
10/22/2025
Special inspection requirement — Final
Joseph Bazini
05/02/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/14/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/19/2021
Violation issued (ECB, open)
Elevators
01/14/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/24/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/05/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/17/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/03/2012
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/04/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/12/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/12/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/21/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/31/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/01/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/26/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offDYNAIRE LLC08/12/2026
DOB NOWPlumbingPermit IssuedMCCREADY & RICE PLUMBING06/15/2026
DOB NOWMechanical SystemsPermit IssuedDYNAIRE LLC06/10/2026
DOB NOWPlumbingPermit IssuedMCCREADY & RICE PLUMBING12/03/2025
DOB NOWGeneral ConstructionSigned-offDYNAIRE12/01/2025
BISSPISSUEDCAPITOL FIRE SPRINKLER CO08/21/2018
BISMHISSUEDNEW VISION BUILDERS01/05/2018
BISOTISSUEDNEW VISION BUILDERS01/05/2018
BISOTISSUEDNEW VISION BUILDERS01/05/2018
BISOTISSUEDNEW VISION BUILDERS10/02/2017
BISOTISSUEDNEW VISION BUILDERS10/02/2017
BISSPISSUEDCAPITOL FIRE SPRINKLER CO08/21/2017
BISPLISSUEDA PLUS PLUMBING CORP07/27/2017
BISMHISSUEDNEW VISION BUILDERS07/25/2017
BISOTISSUEDPEPSI COLA BOTTLING CO06/15/2006
BISOTISSUEDBERZAK GOLD PC02/07/2005
BISMHISSUEDADMIRAL AIR CONDITION COR11/20/2002
BISOTISSUEDALTA MANAGEMENT CORP07/15/2002
BISPLISSUEDVILLAGE P & H NY INC04/04/2002
BISMHISSUEDALTA MANAGEMENT CORP04/04/2002
BISPLISSUEDVILLAGE P & H NY INC02/22/2002
BISSPISSUEDVILLAGE P & H NY INC02/22/2002
BISPLISSUEDVILLAGE P & H NY INC01/23/2002
BISMHISSUEDJ K H CONTRACTING INC.05/22/2001
BISPLISSUEDVILLAGE P & H NY INC04/19/2001
BIS—ISSUEDJ K H CONTRACTING, INC.04/17/2001
BISEQISSUEDJ K H CONTRACTING, INC.04/17/2001
2 projects · most recent 06/03/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/03/2026Permit IssuedDYNAIRE LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Carrier 48GEFM09A2M5-8W2C0 114,820 BTU · Rooftop Unit ×3
48GEFM06A2M5-8W2C0 5 tons · Rooftop Unit ×2
Ventilation
Carrier 48GEFM09A2M5-8W2C0 3,400 CFM · Rooftop Unit ×3
48GEFM06A2M5-8W2C0 2,000 CFM · Rooftop Unit ×2
11/26/2025Signed-offDYNAIRE LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Carrier 48GEEM06A3M5-3W2C0 5 tons · Rooftop Unit ×1
48GEEM12A3M5-3W1C0 10 tons · Rooftop Unit ×1
48GEEM14A3M5-3W2C0 158,190 BTU · Rooftop Unit ×1
48GEFM17A3M5-3W2C0 15 tons · Rooftop Unit ×1
48GEFM24A3M5-3W2C0 20 tons · Rooftop Unit ×1
48GEFM28A3M5-3W2C0 25 tons · Rooftop Unit ×1
Ventilation
Carrier 48GEEM06A3M5-3W2C0 2,000 CFM · Rooftop Unit ×1
48GEEM12A3M5-3W1C0 4,000 CFM · Rooftop Unit ×1
48GEEM14A3M5-3W2C0 5,000 CFM · Rooftop Unit ×1
48GEFM17A3M5-3W2C0 6,000 CFM · Rooftop Unit ×1
48GEFM24A3M5-3W2C0 8,000 CFM · Rooftop Unit ×1
48GEFM28A3M5-3W2C0 10,000 CFM · Rooftop Unit ×1
1 project · most recent 06/03/2026
Gas
FiledStatusContractorScope
06/03/2026Permit IssuedMCCREADY & RICE PLUMBINGGas
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/19/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
11/26/2025HVAC-R and service water heating equipmentJoseph Bazinienergy_progress
10/22/2025Mechanical SystemsJoseph Bazinispecial
10/22/2025FinalJoseph Baziniprogress
▾Documents — 67 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026Q01306770-S1Request digital key ↗
08/18/2026Q01306770-I1Request digital key ↗
08/16/2026Q01402311-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits13
▸BISWORK PERMIT APPLICATION7
01/10/2018421558745Open ↗
01/10/2018421530873Open ↗
01/10/2018421558745Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
11/07/2019421530873Open ↗
11/06/2019421558745Open ↗
11/29/2017421530873Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications17
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
07/18/2019421530873Open ↗
07/18/2019421558745Open ↗
10/06/2017421558745Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/18/2026Q01306770-S1Open ↗
08/18/2026Q01306770-I1Open ↗
08/16/2026Q01402311-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
10/06/2017421558745Open ↗
10/06/2017421558745Open ↗
07/26/2017421530873Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026Q01306770-I1Open ↗
08/24/2026Q01306770-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/06/2017421558745Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q01306770-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/29/2017421530873Open ↗
07/26/2017421530873Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
10/06/2017421558745Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/18/2026Q01306770-S1Open ↗
08/18/2026Q01306770-I1Open ↗
08/16/2026Q01402311-S1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/13/2017421558745Open ↗
07/26/2017421530873Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
08/14/2019421530873Open ↗
07/26/2019421530873Open ↗
07/18/2019421558745Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
08/14/2019421530873Open ↗
07/26/2019421530873Open ↗
07/18/2019421558745Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
08/14/2019421530873Open ↗
07/26/2019421530873Open ↗
07/18/2019421558745Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
07/18/2019421530873Open ↗
07/18/2019421558745Open ↗
07/18/2019421558745Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET3
10/06/2017421558745Open ↗
10/06/2017421558745Open ↗
07/26/2017421530873Open ↗
▸BISBOROUGH INTAKE FORM3
05/19/2020421530873Open ↗
11/06/2019421558745Open ↗
07/18/2019421558745Open ↗