DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 INTERNAL HGH PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL HGH PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL HIGH PRESSURE INSPECTION
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 EXTERNAL HIGH PRESSURE BOILER INSPECTION
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
DOB06/22/2018VIOLATION ISSUED FOR FAILURE TO FILE 2016 ANNUAL HIGH PRESSURE BOILER INSPECTION
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
HPD03/12/2002§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC CEILING LIGHT FIXTURE 2ND STORY PUBLIC HALL.
HPD03/12/2002§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER 2ND STORY REAR APARTMENT #2R. ER-1
DOB10/12/198932/46A/24A/24B/37/20B INADEQUATE VENTILATION-LOW WATER CUTOFF BLOWDOWN PIPE AND VALVE CORRODED/REPLACE-HOT WATER PIPING CONNECTIONS CORRODED- FRONT RIGHT SIDE OF BOILER INSTALL BOTTOM BLOWDOWN VALVE-REPLACE BAROMETRIC DAMPER/DEFECTIVE-CLEAN AND OVERHALL OIL BURNER
ECB08/14/2001FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED IN BASEMENT.INSTALLATION OF A NEW BOILER AND HOT WATER TANK (STORAGE) WITH PUMP AND ALL RELATED PIPING.REMEDY:PERFORM TESTNothing owed — awaiting certificate of correction
ECB08/14/2001PLUMBING WORK WITHOUT A PERMIT.IN BSMT ALL WORK 100% COMPLETE INSTALLATION OF A NEW BOILER AND HOT WATER STORAGE TANK WITH DUMP AND ALL RELATED PIPING.REMEDY:OBTAIN A PERMIT OR RESTORE BACK TO PRIOR LEGAL CONDINothing owed — awaiting certificate of correction
ECB07/18/200049-HAND HOLES WELDED RECEIPT FROM CERTIFIED WELDER HOLDING "R"STAMP TOSUBMIT.2 VALVES IN BLOW DOWN AND WATER COLUMN LINES TO INSTALL.WATER COLUMN LINE REDUCED.DRAIN PIPE UNDER GAGE GLASS TO FIT.WATER PUMP MALFNothing owed — awaiting certificate of correction
ECB10/12/1989HOT WATER PIPING CONNECTIONS CORRODED FRONT RIGHT SIDE OF BOILER INSTALL BOTTOM BLOWDOWN VALVE REPLACE BAROMETRIC DAMPER DEFECTIVE CLEAN AND OVER HAUL OIL BURNERNothing owed — awaiting certificate of correction