← Back
Two family converted from one family
116-43 219 STREET
QUEENS · BIN 4244324
💬 Discuss this project
1930Year Built
2Stories
B3Building Class
R3AZoning
1,344 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,542 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Cellar4p · 2 filings · 19 docs
2 jobs · most recent 01/10/2025
Gas Water/Sanitary
FiledStatusContractorScope
01/10/2025Permit IssuedTRI CITY MECHANICAL GROUPGas, Water/Sanitary
07/29/2024——Gas, Water/Sanitary
1 job · most recent 06/17/2025
General Wiring
FiledStatusContractorScope
06/17/2025Permit IssuedSPICE ELECTRIC COMPANYGeneral Wiring
1 job · most recent 01/10/2025
FiledStatusContractorScope
01/10/2025Permit IssuedUPSTRATE INC1 scope_items
Building Lifecycle
All (32)Filed (6)Permit Issued (2)Violation (3)Objection (10)Special Inspection (11)
01/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
SHI YAN
01/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHI YAN
01/21/2025
Special inspection requirement — Final
SHI YAN
01/21/2025
Special inspection requirement — Footing and Foundation
SHI YAN
01/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
SHI YAN
01/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHI YAN
01/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SHI YAN
01/10/2025
Filed — Alteration
TO RESOLVE ECB VIOLATION#34227142N;34282210H & DOB VIOLATION# 041301C13BL02 BY FILING PLUMBING WORK IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK Q01101871-I1 AS PER PLAN FILED HEREWITH. THIS JOB APPLICATION IS SUPERSEDING DOB BIS ALT-2 #401274376 PL WORK
Q01101834-P1
01/10/2025
Filed — Alteration
REMOVE ILLEGAL PARTITION AND PLUMBING WORK, RESTORE CELLAR TO ACCESSORY USE, AND LEGALIZE CELLAR EGRESS TO THE BACKYARD. THIS APPLICATION IS TO RESOLVE ECB VIOLATION#34227142N #34282210H & DOB VIOLATION# 041301C13BL02 & SUPERSEDING BIS ALT-2 #401274376.
Q01101871-P1
01/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHI YAN
01/07/2025
Special inspection requirement — Tenant Protection Plan Compliance
SHI YAN
01/07/2025
Special inspection requirement — Final
SHI YAN
01/07/2025
Special inspection requirement — Footing and Foundation
SHI YAN
12/19/2024
Permit issued — Foundation
Q01101871-I1-GC-CX
12/18/2024
Permit issued — Plumbing
Q01101834-I1-PL
08/26/2024
Filed — Alteration
REMOVE ILLEGAL PARTITION AND PLUMBING WORK, RESTORE CELLAR TO ACCESSORY USE, AND LEGALIZE CELLAR EGRESS TO THE BACKYARD. THIS APPLICATION IS TO RESOLVE ECB VIOLATION#34227142N #34282210H & DOB VIOLATION# 041301C13BL02 & SUPERSEDING BIS ALT-2 #401274376.
Q01101871-I1
08/26/2024
Filed — Alteration
TO RESOLVE ECB VIOLATION#34227142N;34282210H & DOB VIOLATION# 041301C13BL02 BY FILING PLUMBING WORK IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK Q01101871-I1 AS PER PLAN FILED HEREWITH. THIS JOB APPLICATION IS SUPERSEDING DOB BIS ALT-2 #401274376 PL WORK
Q01101834-I1
08/20/2024
Objection resolved — Resolved
08/20/2024
Objection resolved — Resolved
08/20/2024
Objection resolved — Resolved
08/07/2024
Objection raised — Structural
08/07/2024
Objection raised — Other
08/07/2024
Objection raised — Other
08/07/2024
Objection raised — Other
08/07/2024
Objection raised — Other
08/07/2024
Objection raised — Other
08/07/2024
Objection raised — Accessibility
07/29/2024
Filed — Alteration
Q01084276-I1
07/29/2024
Filed — Alteration
Q01084280-I1
04/13/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
04/13/2001
Violation issued (ECB, closed)
Construction
10/19/1999
Violation issued (ECB, closed)
Quality of Life
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 116-43 219 STREE103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/30/2024$725K—— → —$539/sf building
04/18/2024$315K—Private party → MID ISLAND 104 LLC$234/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YAN ENGINEERING PLLC601/10/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
UPSTRATE INCGeneral Contractor203/21/2026
SPICE ELECTRIC COMPANYElectrical103/22/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAN ENGINEERING PLLC7851401/10/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedUPSTRATE INC12/19/2024
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP12/18/2024
BISOTISSUEDJCS CONSULTANTS INC07/05/2001
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
01/21/2025Tenant Protection Plan ComplianceSHI YANspecial
01/21/2025Fire-Resistant Penetrations and JointsSHI YANspecial
01/21/2025FinalSHI YANprogress
01/21/2025Footing and FoundationSHI YANprogress
01/21/2025Tenant Protection Plan ComplianceSHI YANspecial
01/21/2025Fire-Resistant Penetrations and JointsSHI YANspecial
01/21/2025HVAC-R and service water piping design and insulationSHI YANenergy_progress
01/07/2025Fire-Resistant Penetrations and JointsSHI YANspecial
01/07/2025Tenant Protection Plan ComplianceSHI YANspecial
01/07/2025FinalSHI YANprogress
01/07/2025Footing and FoundationSHI YANprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026Q01101834-I1Request digital key ↗
08/21/2026Q01101834-P1Request digital key ↗
08/21/2026Q01101871-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
02/04/2025401274376Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026Q01084276-I1Open ↗
08/21/2026Q01101834-P1Open ↗
08/21/2026Q01101834-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/02/2026Q01101871-I1Open ↗
09/01/2026Q01101834-I1Open ↗
08/24/2026Q01101871-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026Q01101871-I1Open ↗
09/01/2026Q01101834-I1Open ↗
08/24/2026Q01101871-P1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026Q01101834-I1Open ↗
08/21/2026Q01101834-P1Open ↗
08/21/2026Q01101871-I1Open ↗
Showing 3 of 6 on file for this type
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/21/2026Q01101871-I1Open ↗