← Back
Parochial school, yeshiva
Saints Philip and James and MS 3 Charter School
1160 EAST 213 STREET · Williamsbridge-Olinville · BIN 2059782
💬 Discuss this project
1953Year Built
4Stories
W2Building Class
R5Zoning
40,260 sfGross Floor Area
1Units
LL97 Covered3 Open Violations ▸
Parochial school, yeshiva · 62,000 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof9p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar6p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EXCELLENCE COMMUNITY SCHOOLS1307/08/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW AGE ENGINEERING PLLC603/21/2026
A1 EXPEDITING SERVICE403/21/2026
NOEL BUILDING CONSULTING INC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BJS RENOVATIONS INCGeneral Contractor907/08/2026
YARKS NYC INCGeneral Contractor704/09/2026
RICHARD NEUElectrical103/21/2026
MAMC CONSULTING REPS LLCGeneral Contractor107/08/2026
CAPE PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MELDAN GROUP LLC8100104/24/2025
NEW AGE ENGINEERING PLLC7746808/22/2024
AK ENGINEERING PC678105/28/2024
Building Lifecycle
All (72)Filed (10)Permit Issued (10)Signed Off (4)Violation (8)Inspection (8)Objection (2)Special Inspection (30)
02/18/2026
Permit issued — Supported Scaffold
X01225080-S1-SF
11/07/2025
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/27/2025
Signed off — Alteration
Remove and rebuild damaged masonry parapet wall down to metal flashing on roof side and down to 4 brick courses above window lintels on the street side.
X01213164-I1
06/02/2025
Permit issued — General Construction
X01213164-I1-GC
05/22/2025
Filed — Alteration
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X01225080-S1
05/22/2025
Permit issued — Supported Scaffold
X01225080-S1-SF
05/16/2025
Permit issued — Sidewalk Shed
X01225080-I1-SH
05/15/2025
Filed — Alteration
TEMPORARY PIPE SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
X01225080-I1
04/28/2025
Permit issued — General Construction
X01213164-I1-GC
04/24/2025
Filed — Alteration
Remove and rebuild damaged masonry parapet wall down to metal flashing on roof side and down to 4 brick courses above window lintels on the street side.
X01213164-I1
04/18/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/07/2025
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
04/01/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/23/2024
Signed off — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-S3
09/17/2024
Signed off — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-I1
09/11/2024
Permit issued — Structural
X01045941-S3-ST
09/11/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/10/2024
Signed off — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-S2
09/04/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/23/2024
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
08/23/2024
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
Stephen Shishko
08/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
08/23/2024
Special inspection requirement — Chimneys and vents
Stephen Shishko
08/23/2024
Special inspection requirement — Mechanical Systems
Stephen Shishko
08/23/2024
Special inspection requirement — Final
Stephen Shishko
08/23/2024
Special inspection requirement — Maintenance information
Stephen Shishko
08/23/2024
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
08/23/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
08/22/2024
Filed — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-P3
08/21/2024
Special inspection requirement — Final
Stephen Shishko
08/21/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
08/21/2024
Special inspection requirement — Maintenance information
Stephen Shishko
08/21/2024
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
08/21/2024
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
08/21/2024
Special inspection requirement — Chimneys and vents
Stephen Shishko
08/21/2024
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
Stephen Shishko
08/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
08/21/2024
Special inspection requirement — Mechanical Systems
Stephen Shishko
07/25/2024
Permit issued — General Construction
X01045941-S2-GC
07/22/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
07/17/2024
Special inspection requirement — Final
Stephen Shishko
07/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
07/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
Stephen Shishko
07/17/2024
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
07/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
07/15/2024
Filed — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-P2
07/11/2024
Filed — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-P1
07/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
07/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
07/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
07/01/2024
Special inspection requirement — Final
Stephen Shishko
07/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
Stephen Shishko
06/27/2024
Permit issued — Plumbing
X01045941-S1-PL
06/26/2024
Permit issued — Mechanical Systems
X01045941-I1-MS
06/12/2024
Permit issued — General Construction
X01045941-S2-GC
06/11/2024
Objection resolved — Addressed
06/10/2024
Objection raised — Other
05/28/2024
Filed — Alteration
INSTALL NEW STRUCTURAL SUPPORTS FOR NEW MECHANICAL EQUIPMENT FOR COMMERCIAL KITCHEN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
X01045941-S3
05/28/2024
Special inspection requirement — Post-installed Anchors
Ari Kamo
05/28/2024
Special inspection requirement — Structural Steel - Welding
Ari Kamo
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldPermit IssuedYARKS NYC INC02/18/2026
DOB NOWGeneral ConstructionSigned-offBJS RENOVATIONS INC06/02/2025
DOB NOWSupported ScaffoldPermit IssuedYARKS NYC INC05/22/2025
DOB NOWSidewalk ShedPermit IssuedYARKS NYC INC05/16/2025
DOB NOWGeneral ConstructionSigned-offBJS RENOVATIONS INC04/28/2025
DOB NOWStructuralSigned-offBJS RENOVATIONS INC09/11/2024
DOB NOWGeneral ConstructionSigned-offBJS RENOVATIONS INC07/25/2024
DOB NOWPlumbingPermit IssuedCAPE PLUMBING INC06/27/2024
DOB NOWMechanical SystemsSigned-offMAMC CONSULTING REPS LLC06/26/2024
DOB NOWGeneral ConstructionSigned-offBJS RENOVATIONS INC06/12/2024
BISPLISSUEDALKLEM PLUMBING INC11/08/2013
BISFBISSUEDMARLANDE HEATING CORPORA10/11/2012
BISPLISSUEDALKLEM PLUMBING INC10/11/2012
1 project · most recent 08/22/2024
Heating and Air Conditioning Systems Others
FiledStatusContractorScopeMake / Model / Capacity
08/22/2024Signed-offBJS RENOVATIONS INCHeating and Air Conditioning Systems, Others
Heat / Cool
Mitsubishi Electric MSZ-GS12NA 13,600 BTU · Ahu ×6
MSZ-GS06NA 8,700 BTU · Ahu ×2
MSZ-GS18NA 21,000 BTU · Ahu ×2
MXZ-SM60NAM 66,000 BTU · Condensing Unit ×2
Other
Accurex XBEW-127-S 2,100 CFM · Kitchen Exhaust ×2
XCUBE-140-10 2,100 CFM · Kitchen Exhaust ×2
XDGX-P115-H05-VFD 1,680 CFM · Makeup Air ×2
1 project · most recent 08/22/2024
Gas Water/Sanitary
FiledStatusContractorScope
08/22/2024Permit IssuedCAPE PLUMBING INCGas, Water/Sanitary
2 projects · most recent 02/20/2026
General Wiring
FiledStatusContractorScope
02/20/2026Permit IssuedRICHARD NEU—
07/16/2024CompleteINFINITI ELECTRIC CORPGeneral Wiring
1 project · most recent 08/22/2024
Steel
FiledStatusContractorScope
08/22/2024Signed-offBJS RENOVATIONS INCSteel
1 project · most recent 05/22/2025
Scaffold Sidewalk Shed
FiledStatusContractorScope
05/22/2025Permit IssuedYARKS NYC INCScaffold, Sidewalk Shed
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
11/07/2025Pass-Final PL - UndergroundPassView ↗
04/18/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/07/2025Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
04/01/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/11/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/04/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2024Pass-Final PL - UndergroundPassView ↗
04/14/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
08/23/2024HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
08/23/2024Exhaust and Vent Systems in Plenums and DuctsStephen Shishkospecial
08/23/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
08/23/2024Chimneys and ventsStephen Shishkospecial
08/23/2024Mechanical SystemsStephen Shishkospecial
08/23/2024FinalStephen Shishkoprogress
08/23/2024Maintenance informationStephen Shishkoenergy_progress
08/23/2024HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
08/23/2024HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
08/21/2024FinalStephen Shishkoprogress
08/21/2024HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
08/21/2024Maintenance informationStephen Shishkoenergy_progress
08/21/2024HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
08/21/2024HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
08/21/2024Chimneys and ventsStephen Shishkospecial
08/21/2024Exhaust and Vent Systems in Plenums and DuctsStephen Shishkospecial
08/21/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
08/21/2024Mechanical SystemsStephen Shishkospecial
07/17/2024FinalStephen Shishkoprogress
07/17/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
07/17/2024Fire-Resistance Rated ConstructionStephen Shishkoprogress
07/17/2024Energy Code Compliance InspectionsStephen Shishkoprogress
07/16/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
07/01/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
07/01/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
Latest 25 of 33.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Excellence CommunityRestaurant / Food ServiceFloor 1
Project X01045941 Alteration · Permit Entire · 05/22/2024
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 94 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/21/2026X01045941-P3Request digital key ↗
08/21/2026X01045941-P2Request digital key ↗
08/21/2026X01045941-P1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits5
▸BISWORK PERMIT APPLICATION4
11/21/2013220236607Open ↗
10/11/2012220236607Open ↗
10/11/2012220236607Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION1
10/11/2012220236607Open ↗
▸Seals & Professional Certifications44
▸DOB NOWProgress Inspector Seal & Signature17
09/02/2026X01045941-P3Open ↗
09/02/2026X01045941-P3Open ↗
09/02/2026X01045941-P3Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/02/2026X01045941-P3Open ↗
09/02/2026X01045941-P3Open ↗
09/02/2026X01045941-P3Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/21/2026X01045941-P3Open ↗
08/21/2026X01045941-P2Open ↗
08/21/2026X01045941-P1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
10/11/2012220236607Open ↗
10/11/2012220236607Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/11/2012220236607Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/11/2012220236607Open ↗
▸Trade Schedules & Equipment6
▸BISSELF-CERT PLUMBING NOTICE2
02/05/2014220236607Open ↗
11/25/2013220236607Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
10/11/2012220236607Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
12/13/2023220236607Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
12/03/2013220236607Open ↗
▸BISSCHEDULE B - PLUMBING1
10/11/2012220236607Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/21/2026X01045941-S1Open ↗
08/21/2026X01045941-P3Open ↗
08/21/2026X01045941-P2Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/11/2012220236607Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
10/11/2012220236607Open ↗
10/11/2012220236607Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
12/13/2023220236607Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
12/13/2023220236607Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026X01045941-I1Open ↗
▸Inspections & Test Reports1
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
12/13/2023220236607Open ↗
▸Approvals, Objections & Sign-offs12
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter10
08/21/2026X01045941-P3Open ↗
08/21/2026X01045941-P2Open ↗
08/21/2026X01045941-P1Open ↗
Showing 3 of 10 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/14/2023220236607Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/11/2012220236607Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
10/11/2012220236607Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
12/13/2023220236607Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
10/11/2012220236607Open ↗