← Back
Miscellaneous two family
Devoe Condominium
117 POWERS STREET · BIN 3069228
💬 Discuss this project
1920Year Built
2Stories
B9Building Class
R6BZoning
1,182 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Miscellaneous two family · Owner of record: 117 POWERS LLC · 2,600 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction18p · 1 filing · 20 docs
Floor 4Under Construction19p · 1 filing · 20 docs
Floor 3Under Construction19p · 1 filing · 20 docs
Floor 2Under Construction20p · 1 filing · 20 docs
Floor 1Under Construction19p · 1 filing · 20 docs
CellarUnder Construction21p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
117 POWERS5807/08/2026
DEVOE CONDO LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/23/2024$2.1M—Private party → 117 POWERS LLC$1,777/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING3003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Y&L INTERIOR LLCGeneral Contractor2807/08/2026
APEX GROUP NY CORPGeneral Contractor404/09/2026
LENS ELECTRIC, INCElectrical103/22/2026
QUALITY PIPING, INCFire Protection107/08/2026
NESS MECHANICAL P & H INCPlumbing107/01/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161608/24/2026
Building Lifecycle
All (152)Filed (21)Permit Issued (23)Signed Off (4)Violation (2)Inspection (8)Objection (64)Special Inspection (30)
08/31/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
Propose Mechanical Scope of work for a new enlargement of an existing 2-story residential building to a new MDL Class A Apartment Building, filed in conj. w/ Alt-CO-NB # B01042283-I1
B01042283-S7
08/24/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Propose Mechanical Scope of work for a new enlargement of an existing 2-story residential building to a new MDL Class A Apartment Building, filed in conj. w/ Alt-CO-NB # B01042283-I1
B01042283-A1
08/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Shutoff dampers
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Duct leakage testing, insulation and design
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Final
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Mechanical Systems
SHAHRIAR QUAYYUM
08/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
07/10/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/07/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/21/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
05/21/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/21/2026
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
05/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
05/21/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
05/21/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
05/18/2026
Objection resolved — Addressed
05/13/2026
Objection raised — Energy
05/08/2026
Signed off — Alteration
Installation of temporary sidewalk shed per plan submitted. No change in use, egress and/or occupancy with this application.
B01310710-I1
05/08/2026
Signed off — Alteration
Installation of supported scaffold per plan submitted. No change in use, egress and/or occupancy with this application.
B01347932-I1
05/08/2026
Signed off — Alteration
Installation of Roof Protection as per plans for protection over neighboring buildings 115 Powers Street & 119 Powers Street
B01276087-I1
05/08/2026
Permit issued — Structural
B01166494-I1-ST
05/07/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Propose Mechanical Scope of work for a new enlargement of an existing 2-story residential building to a new MDL Class A Apartment Building, filed in conj. w/ Alt-CO-NB # B01042283-I1
B01042283-P7
05/06/2026
Permit issued — General Construction
B01042283-I1-GC
05/06/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
05/06/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
05/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
05/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
05/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
05/06/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
05/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
03/17/2026
Permit issued — Mechanical Systems
B01042283-S1-MS
03/13/2026
Permit issued — Foundation
B01042283-S5-FO
03/13/2026
Permit issued — Foundation
B01042283-S7-FO
03/13/2026
Permit issued — General Construction
B01042283-I1-GC
03/12/2026
Permit issued — Construction Fence
B01042283-S8-FN
03/11/2026
Permit issued — Support of Excavation
B01042283-S6-SE
03/11/2026
Permit issued — Structural
B01042283-S4-ST
02/03/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/03/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/20/2026
Permit issued — Supported Scaffold
B01347932-I1-SF
01/17/2026
Filed — Alteration
Installation of supported scaffold per plan submitted. No change in use, egress and/or occupancy with this application.
B01347932-I1
01/06/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/17/2025
Filed — Alteration
Installation of temporary sidewalk shed per plan submitted. No change in use, egress and/or occupancy with this application.
B01310710-P1
10/31/2025
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
10/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
10/31/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
10/30/2025
Permit issued — Sidewalk Shed
B01310710-I1-SH
10/29/2025
Filed — Alteration
Installation of temporary sidewalk shed per plan submitted. No change in use, egress and/or occupancy with this application.
B01310710-I1
10/29/2025
Objection raised — Inspections
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Structural
10/29/2025
Objection resolved — Addressed
Latest 60 of 152 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offY&L INTERIOR LLC05/08/2026
DOB NOWGeneral ConstructionPermit IssuedY&L INTERIOR LLC05/06/2026
DOB NOWMechanical SystemsSigned-offY&L INTERIOR LLC03/17/2026
DOB NOWFoundationSigned-offY&L INTERIOR LLC03/13/2026
DOB NOWFoundationSigned-offY&L INTERIOR LLC03/13/2026
DOB NOWGeneral ConstructionPermit IssuedY&L INTERIOR LLC03/13/2026
DOB NOWConstruction FencePermit IssuedY&L INTERIOR LLC03/12/2026
DOB NOWSupport of ExcavationSigned-offY&L INTERIOR LLC03/11/2026
DOB NOWStructuralSigned-offY&L INTERIOR LLC03/11/2026
DOB NOWSupported ScaffoldSigned-offAPEX GROUP NY CORP01/20/2026
DOB NOWSidewalk ShedSigned-offAPEX GROUP NY CORP10/30/2025
DOB NOWProtection and Mechanical MethodsSigned-offAPEX GROUP NY CORP08/25/2025
DOB NOWPlumbingSigned-offNESS MECHANICAL P & H INC07/30/2025
DOB NOWSprinklersPermit IssuedQUALITY PIPING, INC07/29/2025
DOB NOWGeneral ConstructionPermit IssuedY&L INTERIOR LLC05/12/2025
DOB NOWStructuralSigned-offY&L INTERIOR LLC02/24/2025
DOB NOWStructuralSigned-offY&L INTERIOR LLC02/21/2025
DOB NOWMechanical SystemsSigned-offY&L INTERIOR LLC02/21/2025
DOB NOWFoundationSigned-offY&L INTERIOR LLC02/20/2025
DOB NOWConstruction FencePermit IssuedY&L INTERIOR LLC02/20/2025
DOB NOWSupport of ExcavationSigned-offY&L INTERIOR LLC02/20/2025
DOB NOWGeneral ConstructionPermit IssuedY&L INTERIOR LLC02/20/2025
DOB NOWFoundationSigned-offY&L INTERIOR LLC02/20/2025
1 project · most recent 08/24/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/24/2026Permit IssuedY&L INTERIOR LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAMHZ 42,000 BTU · Heat Pump Outdoor ×7
Ventilation
Greenheck CSP-B110 70 CFM · Exhaust Fan ×1
G-097-VG 175 CFM · Exhaust Fan ×1
G-098-VG 500 CFM · Exhaust Fan ×1
G-099-VG 700 CFM · Kitchen Exhaust ×1
1 project · most recent 08/24/2026
Sprinkler System
FiledStatusContractorScope
08/24/2026Permit IssuedQUALITY PIPING, INCSprinkler System
1 project · most recent 08/24/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/24/2026Signed-offQUALITY PIPING, INCGas, Storm, Water/Sanitary
2 projects · most recent 04/22/2026
General Wiring
FiledStatusContractorScope
04/22/2026CompleteLENS ELECTRIC, INCGeneral Wiring
03/26/2026Permit IssuedHIGH QUALITY ELEC.OF NYC—
2 projects · most recent 08/24/2026
Concrete Masonry
FiledStatusContractorScope
08/24/2026Permit IssuedY&L INTERIOR LLCConcrete, Masonry
01/17/2025Signed-offY&L INTERIOR LLC1 scope_items
3 projects · most recent 08/24/2026
Fence Scaffold Sidewalk Shed
FiledStatusContractorScope
08/24/2026Permit IssuedY&L INTERIOR LLCFence
01/17/2026Signed-offAPEX GROUP NY CORPScaffold
12/17/2025Signed-offAPEX GROUP NY CORPSidewalk Shed
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/10/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/07/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/03/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/03/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/06/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/20/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/15/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 91
DateRequirementInspectorRole
08/20/2026Structural Stability – Alterations of existing buildingsSHAHRIAR QUAYYUMspecial
08/20/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
08/20/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
08/20/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/20/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/20/2026Duct leakage testing, insulation and designSHAHRIAR QUAYYUMenergy_progress
08/20/2026Mechanical SystemsSHAHRIAR QUAYYUMspecial
08/20/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
08/20/2026Shutoff dampersSHAHRIAR QUAYYUMenergy_progress
08/20/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
08/20/2026FinalSHAHRIAR QUAYYUMprogress
08/20/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
05/21/2026HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
05/21/2026HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
05/21/2026HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
05/21/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
05/21/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
05/21/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
05/21/2026Maintenance informationFAHAD FATEHenergy_progress
05/06/2026HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
05/06/2026Maintenance informationFAHAD FATEHenergy_progress
05/06/2026HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
05/06/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
05/06/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
05/06/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
Latest 25 of 91.
▾Documents — 121 on file (BIS + DOB NOW)
▸Plans & Drawings22
▸DOB NOWPlans/Sketch22
08/24/2026B01042283-A2Request digital key ↗
08/22/2026B01042283-A1Request digital key ↗
08/20/2026B01276087-I1Request digital key ↗
Showing 3 of 22 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
05/22/2024340911080Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
10/04/2024340911080Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026B01042283-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/14/2026B01042283-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B01042283-I1Open ↗
▸Seals & Professional Certifications55
▸DOB NOWDPL-1: Design Professional Seal & Signature22
08/24/2026B01042283-A2Open ↗
08/22/2026B01042283-A1Open ↗
08/20/2026B01276087-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature18
09/23/2026B01042283-A1Open ↗
08/31/2026B01042283-P7Open ↗
08/31/2026B01166494-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/23/2026B01042283-A1Open ↗
09/23/2026B01042283-A1Open ↗
08/31/2026B01042283-P7Open ↗
Showing 3 of 14 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
05/22/2024340911080Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/14/2026B01042283-I1Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
08/02/2024340911080Open ↗
05/22/2024340911080Open ↗
▸BISBPP: STREET TREES SITE PLAN1
05/22/2024340911080Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/14/2026B01042283-I1Open ↗
▸Environmental & Asbestos18
▸DOB NOWDEP ACP-5: Asbestos Assessment Report18
08/24/2026B01042283-A2Open ↗
08/22/2026B01042283-A1Open ↗
08/17/2026B01042283-S3Open ↗
Showing 3 of 18 on file for this type
▸Inspections & Test Reports9
▸DOB NOWSOIL REPORT6
08/17/2026B01042283-P1Open ↗
08/17/2026B01042283-P3Open ↗
08/17/2026B01042283-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram3
08/15/2026B01042283-S7Open ↗
08/14/2026B01042283-S5Open ↗
08/14/2026B01042283-S6Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
05/22/2024340911080Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
05/22/2024340911080Open ↗
▸Other Documents5
▸BISBPP - SUPPORTING DOCUMENTATION1
08/02/2024340911080Open ↗
▸DOB NOWSite Survey: Initial1
08/14/2026B01042283-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026B01042283-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/14/2026B01042283-S6Open ↗
▸DOB NOWProperty Ownership Certification1
08/14/2026B01042283-I1Open ↗