← Back
Miscellaneous educational facility
117 WEST 128 STREET
MANHATTAN · Harlem (North) · BIN 1057938
💬 Discuss this project
1910Year Built
3Stories
W9Building Class
R7-2Zoning
20,250 sfGross Floor Area
3Units
6 Open Violations 4 unresolved · 2 paperwork only ▸
Miscellaneous educational facility · Owner of record: 115 WEST 128TH STREET CORP. · 7,433 sf lot · 2.72 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Site & exterior3p · 2 filings · 8 docs
Filed — no permit issued23p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
115 WEST 128403/21/2026
115 W128 ST203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BIANCA V. SKVIRSKY, PE209/15/2025
JEFFREY KAMEN ARCHITECT304/04/2025
BASIC GROUPS CORP311/27/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LOUIS STRIAR403/21/2026
WSCONSULTANT & EXPEDITING SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMERICAN AWNING & SIGN DEGeneral Contractor303/21/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JEFFREY KAMEN ARCHITECT3901304/04/2025
NY ACOM ENGINEERING PLLC7061311/27/2020
Building Lifecycle
All (53)Filed (8)Permit Issued (2)Signed Off (2)Violation (18)Special Inspection (23)
10/09/2025
Signed off — Alteration
FOUR NON-ILLUMINATED NON-ADVERTISING ACCESSORY AWNINGS FOR EDUCATIONAL FACILITY. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01284861-I1
10/09/2025
Signed off — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY WALL BANNER SIGN - WEST HARLEM COMMUNITY ORGANIZATION, INC. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01284858-I1
09/19/2025
Permit issued — Sign
M01284858-I1-SG
09/19/2025
Permit issued — General Construction
M01284861-I1-GC
09/15/2025
Filed — Alteration
FOUR NON-ILLUMINATED NON-ADVERTISING ACCESSORY AWNINGS FOR EDUCATIONAL FACILITY. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01284861-I1
09/15/2025
Filed — Alteration
NON-ILLUMINATED NON-ADVERTISING ACCESSORY WALL BANNER SIGN - WEST HARLEM COMMUNITY ORGANIZATION, INC. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
M01284858-I1
09/15/2025
Special inspection requirement — Final
BIANCA SKVIRSKY
09/15/2025
Special inspection requirement — Final
BIANCA SKVIRSKY
04/04/2025
Filed — Alteration CO
M01033542-S1
03/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JEFFREY KAMEN
03/11/2025
Special inspection requirement — Tenant Protection Plan Compliance
JEFFREY KAMEN
03/11/2025
Special inspection requirement — Interior lighting power
JEFFREY KAMEN
03/11/2025
Special inspection requirement — Fire-Resistance Rated Construction
JEFFREY KAMEN
03/11/2025
Special inspection requirement — Lighting controls
JEFFREY KAMEN
03/11/2025
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY KAMEN
03/04/2025
Filed — Alteration CO
M01033542-P1
01/29/2025
Special inspection requirement — Lighting controls
JEFFREY KAMEN
01/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JEFFREY KAMEN
01/29/2025
Special inspection requirement — Tenant Protection Plan Compliance
JEFFREY KAMEN
01/29/2025
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY KAMEN
01/29/2025
Special inspection requirement — Fire-Resistance Rated Construction
JEFFREY KAMEN
01/29/2025
Special inspection requirement — Interior lighting power
JEFFREY KAMEN
11/05/2024
Filed — Alteration CO
M01033542-I1
12/01/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
YING JIANG
12/01/2020
Special inspection requirement — Energy Code Compliance Inspections
YING JIANG
11/27/2020
Filed — Alteration
PROPOSE INSTALL NEW KITCHEN FIXTURE ON 2ND FLOOR COMMERCIAL SPACE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00420065-P1
11/25/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
YING JIANG
11/25/2020
Special inspection requirement — Energy Code Compliance Inspections
YING JIANG
11/09/2020
Filed — Alteration
PROPOSE INSTALL NEW KITCHEN FIXTURE ON 2ND FLOOR COMMERCIAL SPACE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00420065-I1
11/09/2020
Filed — Alteration
PROPOSE EXTEND EXISTING KITCHEN HOOD AT 2ND FLOOR KITCHEN AREA CONNECT TO THE EXISTING EXHAUST. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
M00414994-I1
10/16/2020
Special inspection requirement — Duct leakage testing
YING JIANG
10/16/2020
Special inspection requirement — Mechanical Systems
YING JIANG
10/16/2020
Special inspection requirement — Energy Code Compliance Inspections
YING JIANG
10/16/2020
Special inspection requirement — Final
YING JIANG
10/16/2020
Special inspection requirement — Chimneys and vents
YING JIANG
12/04/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/11/2018
Violation issued (ECB, open)
Construction
09/15/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/26/2016
Violation issued (ECB, open)
Construction
09/26/2016
Violation issued (ECB, open)
Construction
12/31/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/23/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/01/2012
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/08/2010
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/09/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/26/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/25/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/04/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/26/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/08/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC09/19/2025
DOB NOWGeneral ConstructionSigned-offAMERICAN AWNING & SIGN DE09/19/2025
BISPLISSUEDCASA MECHANICAL CO. INC07/18/2014
BISBLISSUEDCASA MECHANICAL CO. INC07/18/2014
BISOTISSUEDR.A. CONTRACTING CO03/16/2005
BIS—ISSUEDDBB ARCHITECTURE12/06/2000
BISOTISSUEDRA CONSTRACTING CO01/21/1999
BISPLISSUEDDUAL FUEL PLUMBING & HEATING10/02/1992
1 project · most recent 11/09/2020
Ventilation Systems
FiledStatusContractorScope
11/09/2020——Ventilation Systems
1 project · most recent 11/27/2020
Gas
FiledStatusContractorScope
11/27/2020——Gas
1 project · most recent 01/09/2024
General Wiring
FiledStatusContractorScope
01/09/2024Permit IssuedTOTAL ELECTRIC SOLUTIONSGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
09/15/2025FinalBIANCA SKVIRSKYprogress
09/15/2025FinalBIANCA SKVIRSKYprogress
03/11/2025Fire-Resistant Penetrations and JointsJEFFREY KAMENspecial
03/11/2025Tenant Protection Plan ComplianceJEFFREY KAMENspecial
03/11/2025Interior lighting powerJEFFREY KAMENenergy_progress
03/11/2025Fire-Resistance Rated ConstructionJEFFREY KAMENprogress
03/11/2025Lighting controlsJEFFREY KAMENenergy_progress
03/11/2025Energy Code Compliance InspectionsJEFFREY KAMENprogress
01/29/2025Lighting controlsJEFFREY KAMENenergy_progress
01/29/2025Fire-Resistant Penetrations and JointsJEFFREY KAMENspecial
01/29/2025Tenant Protection Plan ComplianceJEFFREY KAMENspecial
01/29/2025Energy Code Compliance InspectionsJEFFREY KAMENprogress
01/29/2025Fire-Resistance Rated ConstructionJEFFREY KAMENprogress
01/29/2025Interior lighting powerJEFFREY KAMENenergy_progress
12/01/2020Fire-Resistant Penetrations and JointsYING JIANGspecial
12/01/2020Energy Code Compliance InspectionsYING JIANGprogress
11/25/2020Fire-Resistant Penetrations and JointsYING JIANGspecial
11/25/2020Energy Code Compliance InspectionsYING JIANGprogress
10/16/2020Duct leakage testing YING JIANGenergy_progress
10/16/2020Mechanical SystemsYING JIANGspecial
10/16/2020Energy Code Compliance InspectionsYING JIANGprogress
10/16/2020FinalYING JIANGprogress
10/16/2020Chimneys and ventsYING JIANGspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
West Harlem Community OrganizationOffice—
Project M01284858 Alteration · LOC Issued · 09/15/2025
Project M01284861 Alteration · LOC Issued · 09/15/2025
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch5
08/24/2026M01033542-P1Request digital key ↗
08/24/2026M01033542-S1Request digital key ↗
08/24/2026M01033542-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Plumbing2
09/04/2026M00420065-P1Request digital key ↗
09/04/2026M00420065-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00414994-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
07/17/2014140227323Open ↗
03/26/2013121554790Open ↗
▸BISWORK PERMIT APPLICATION2
07/17/2014140227323Open ↗
07/17/2014140227323Open ↗
▸Seals & Professional Certifications36
▸DOB NOWProgress Inspector Seal & Signature15
09/23/2026M01284858-I1Open ↗
08/27/2026M01284861-I1Open ↗
08/26/2026M00420065-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/04/2026M00420065-P1Open ↗
09/04/2026M00420065-I1Open ↗
08/24/2026M01033542-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/26/2026M00420065-P1Open ↗
08/26/2026M01033542-I1Open ↗
08/26/2026M01033542-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
07/25/2016140227323Open ↗
03/26/2013121554790Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/17/2014140227323Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/17/2014140227323Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/17/2014140227323Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING2
07/17/2014140227323Open ↗
03/26/2013121554790Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
07/17/2014140227323Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
04/13/2015140227323Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/24/2026M01033542-I1Open ↗
08/24/2026M01033542-P1Open ↗
▸BISSTREET TREE CHECKLIST1
03/26/2013121554790Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/04/2026M00420065-P1Open ↗
09/04/2026M00420065-I1Open ↗
08/24/2026M01033542-S1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)1
03/26/2013121554790Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
03/26/2013121554790Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/17/2014140227323Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/17/2014140227323Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
07/25/2016140227323Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/17/2014140227323Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/25/2016140227323Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/17/2014140227323Open ↗
▸Approvals, Objections & Sign-offs7
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/24/2026M01033542-S1Open ↗
08/24/2026M01033542-P1Open ↗
08/24/2026M01033542-I1Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/25/2016140227323Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/25/2016140227323Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
03/26/2013121554790Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/26/2013121554790Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
07/25/2016140227323Open ↗
07/17/2014140227323Open ↗
03/26/2013121554790Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
08/20/2014140227323Open ↗
▸BISEFILING COVER SHEET1
03/26/2013121554790Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/17/2014140227323Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification2
08/24/2026M01033542-P1Open ↗
08/24/2026M01033542-I1Open ↗
▸BISPLOT DIAGRAM1
03/26/2013121554790Open ↗