← Back
Two family brick
1176 68 STREET
BROOKLYN · Dyker Heights · BIN 3143165
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R5BZoning
2,280 sfGross Floor Area
2Units
Two family brick · 2,200 sf lot · 1.04 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/04/2021$1.1M—Private party → Private party$463/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KOH HO LEE CONSULTING ENGINEER509/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KON HO LEE CONSULTING ENGINEER PLL1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YUNG WAY CONSTRUCTION INC.General Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KON HO LEE CONSULTING ENG6504509/27/2021
Building Lifecycle
All (18)Filed (5)Permit Issued (2)Signed Off (2)Inspection (2)Special Inspection (7)
10/15/2021
Signed off — Alteration
Interior renovation of existing two family building. No change in use, occupancy or egress.
B00502454-I1
10/15/2021
Signed off — Alteration
Remove(1)boiler,(1)H.W.H.,(1)lavatory&(1)water closet.Install(2)boiler,(2)H.W.H.,(1)floor drain,(1)dryer,(1)washer machine,(1)lavatory,(1)shower&(1)water closet at basement.Relocate(1)sink,(1)stove,(1)lavatory,(1)shower&(1)water closet at 1st & 2nd floor.
B00502458-I1
09/27/2021
Filed — Alteration
Remove(1)boiler,(1)H.W.H.,(1)lavatory&(1)water closet.Install(2)boiler,(2)H.W.H.,(1)floor drain,(1)dryer,(1)washer machine,(1)lavatory,(1)shower&(1)water closet at basement.Relocate(1)sink,(1)stove,(1)lavatory,(1)shower&(1)water closet at 1st & 2nd floor.
B00502458-P2
09/27/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
KON LEE
09/27/2021
Special inspection requirement — Energy Code Compliance Inspections
KON LEE
09/27/2021
Special inspection requirement — HVAC-R and service water heating equipment
KON LEE
09/27/2021
Special inspection requirement — HVAC-R and service water heating system controls
KON LEE
09/24/2021
Filed — Alteration
Interior renovation of existing two family building. No change in use, occupancy or egress.
B00502454-P1
09/24/2021
Special inspection requirement — Energy Code Compliance Inspections
KON LEE
09/24/2021
Special inspection requirement — Insulation placement and R values
KON LEE
09/24/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
KON LEE
09/14/2021
Filed — Alteration
Remove(1)boiler,(1)H.W.H.,(1)lavatory&(1)water closet.Install(2)boiler,(2)H.W.H.,(1)floor drain,(1)dryer,(1)washer machine,(1)lavatory,(1)shower&(1)water closet at basement.Relocate(1)sink,(1)stove,(1)lavatory,(1)shower&(1)water closet at 1st & 2nd floor.
B00502458-P1
07/08/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/08/2021
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/12/2021
Permit issued — Plumbing
B00502458-I1-PL
04/22/2021
Permit issued — General Construction
B00502454-I1-GC
04/18/2021
Filed — Alteration
Interior renovation of existing two family building. No change in use, occupancy or egress.
B00502454-I1
04/18/2021
Filed — Alteration
Remove(1)boiler,(1)H.W.H.,(1)lavatory&(1)water closet.Install(2)boiler,(2)H.W.H.,(1)floor drain,(1)dryer,(1)washer machine,(1)lavatory,(1)shower&(1)water closet at basement.Relocate(1)sink,(1)stove,(1)lavatory,(1)shower&(1)water closet at 1st & 2nd floor.
B00502458-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC05/12/2021
DOB NOWGeneral ConstructionSigned-offB & A COMMERCIAL INC04/22/2021
2 projects · most recent 09/24/2021
General Wiring
FiledStatusContractorScope
09/24/2021CompleteINTELOGIC ELECTRIC, INC.3 meters, 3 new_meters
04/30/2021CompleteINTELOGIC ELECTRIC, INC.General Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/08/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/08/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
09/27/2021Fire-Resistant Penetrations and JointsKON LEEspecial
09/27/2021Energy Code Compliance InspectionsKON LEEprogress
09/27/2021HVAC-R and service water heating equipmentKON LEEenergy_progress
09/27/2021HVAC-R and service water heating system controlsKON LEEenergy_progress
09/24/2021Energy Code Compliance InspectionsKON LEEprogress
09/24/2021Insulation placement and R valuesKON LEEenergy_progress
09/24/2021Fire-Resistant Penetrations and JointsKON LEEspecial
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/01/2026B00502454-I1Request digital key ↗
09/01/2026B00502454-P1Request digital key ↗
09/01/2026B00502458-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWRestrictive Declaration/Easement 15
08/13/2026B00502458-P2Open ↗
08/13/2026B00502454-P1Open ↗
08/13/2026B00502458-P1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/01/2026B00502454-I1Open ↗
09/01/2026B00502454-P1Open ↗
09/01/2026B00502458-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/29/2026B00502458-P2Open ↗
08/29/2026B00502458-P2Open ↗
08/29/2026B00502458-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026B00502458-P2Open ↗
08/26/2026B00502454-P1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026B00502454-P1Open ↗
09/01/2026B00502454-I1Open ↗
09/01/2026B00502458-P2Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00502458-I1Open ↗
08/13/2026B00502454-I1Open ↗