← Back
BRONX
1177 LEGGETT AVENUE
BRONX · Hunts Point · BIN 2130904
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Flood zone X
Locations of Work
StructuralMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Roof6p · 1 filing · 17 docs
Bulkhead2p · 1 filing · 17 docs
Floor 118p · 2 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TURNBRIDGE EQUITIES1207/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SAFE RISE LLC102/13/2024
H & O ENGINEERING, DPC212/19/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SAFE RISE103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DNS FINE BUILDERS INCGeneral Contractor807/08/2026
CASA AZOUTR INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
H & O ENGINEERING, DPC5595112/19/2023
Building Lifecycle
All (32)Filed (3)Permit Issued (8)Signed Off (1)Objection (18)Special Inspection (2)
10/31/2024
Signed off — Full Demolition
MECHANICAL MEANS SUBMITTED FOR USE OF MECHANICAL EQUIPMENT AT THE TIME OF DEMOLITION
X00945746-I1
10/17/2024
Permit issued — Full Demolition
X00945746-I1-FD
10/16/2024
Permit issued — Construction Fence
X01005247-I1-FN
04/26/2024
Permit issued — Protection and Mechanical Methods
X00945746-S1-PMM
04/25/2024
Permit issued — Construction Fence
X01005247-I1-FN
04/25/2024
Permit issued — Full Demolition
X00945746-I1-FD
02/26/2024
Permit issued — Protection and Mechanical Methods
X00945746-S1-PMM
02/22/2024
Permit issued — Full Demolition
X00945746-I1-FD
02/16/2024
Permit issued — Construction Fence
X01005247-I1-FN
02/13/2024
Filed — Alteration
X01005247-I1
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/10/2024
Objection resolved — Addressed
01/03/2024
Objection raised — Structural
01/03/2024
Objection raised — C-25
01/03/2024
Objection raised — C-27
01/03/2024
Objection raised — C-25
01/03/2024
Objection raised — Structural
01/03/2024
Objection raised — Structural
01/03/2024
Objection raised — Admin
01/03/2024
Objection raised — Structural
01/03/2024
Objection raised — Mechanical
12/19/2023
Filed — Full Demolition
MECHANICAL MEANS SUBMITTED FOR USE OF MECHANICAL EQUIPMENT AT THE TIME OF DEMOLITION
X00945746-I1
12/19/2023
Filed — Full Demolition
MECHANICAL MEANS SUBMITTED FOR USE OF MECHANICAL EQUIPMENT AT THE TIME OF DEMOLITION
X00945746-S1
12/18/2023
Special inspection requirement — Demolition
SANTIAGO HELMAN
12/18/2023
Special inspection requirement — Structural Stability – Alterations of existing Buildings
SANTIAGO HELMAN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFull DemolitionSigned-offCASA AZOUTR INC10/17/2024
DOB NOWConstruction FencePermit IssuedCASA AZOUTR INC10/16/2024
DOB NOWProtection and Mechanical MethodsSigned-offDNS FINE BUILDERS INC04/26/2024
DOB NOWConstruction FencePermit IssuedDNS FINE BUILDERS INC04/25/2024
DOB NOWFull DemolitionSigned-offDNS FINE BUILDERS INC04/25/2024
DOB NOWProtection and Mechanical MethodsSigned-offDNS FINE BUILDERS INC02/26/2024
DOB NOWFull DemolitionSigned-offDNS FINE BUILDERS INC02/22/2024
DOB NOWConstruction FencePermit IssuedDNS FINE BUILDERS INC02/16/2024
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
12/18/2023DemolitionSANTIAGO HELMANspecial
12/18/2023Structural Stability – Alterations of existing BuildingsSANTIAGO HELMANspecial
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026X00945746-I1Request digital key ↗
08/21/2026X00945746-S1Request digital key ↗
08/21/2026X01005247-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026X00945746-I1Open ↗
08/21/2026X00945746-S1Open ↗
08/13/2026X01005247-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026X00945746-I1Open ↗
08/28/2026X00945746-I1Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWElectric Cut-Off1
08/13/2026X00945746-I1Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026X00945746-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026X00945746-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026X00945746-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026X00945746-I1Open ↗
▸DOB NOWRodent Control1
08/13/2026X00945746-I1Open ↗
▸Other Documents4
▸DOB NOWCommunity Board Notification1
08/13/2026X00945746-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/21/2026X00945746-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026X00945746-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026X00945746-I1Open ↗